N/A 9450003Recalls & reported problems
Medtronic Sofamor Danek, Inc. · DISPOSABLE 9450003 ELECTRO TWST PAIR 8CH · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00721902572715), received between Feb 10, 2017 and Feb 10, 2017 — classified as 1 injury.
The most frequently reported specific device problem is “Material Fragmentation” (1 report).
1 other recall cover devices cleared under the same FDA submission (K031003); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Fragmentation1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 10, 2017Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT FOLLOWING A METRIX DECOMPRESSION WITH EMG MONITORING VIA NIM AND ELECTRODES, "WHEN STAFF WAS REMOVING THE NEEDLE ELECTRODES IT WAS NOTICED THAT ONE NEEDLE HAD BROKEN OFF AND WAS UNDER THE SKIN IN THE MUSCLE OF THE PATIENT, CONFIRMED W XRAY." FRAGMENT REMAINS IN THE EXTENSOR HALLUCIS LONGUS. THERE WAS NO PATIENT INJURY. ADDITIONAL INFORMATION RECEIVED STATING THAT FOR THE PROCEDURE THE ELECTRODE WAS "BENT AT A 90 DEGREE ANGLE TO INSERT AND TO REDUCE THE CHANCE OF THE PLASTIC TIP BEING PULLED OUT OF THE SKIN." WHEN THE FRAGMENT WAS DISCOVERED THE PHYSICIAN HAD PLANNED ON REMOVING IT, HOWEVER, THE PATIENT CHOSE TO LEAVE IT IN.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 6322011 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K031003. One submission often covers many models, so check the product and lot details in each record.
- Z-0947-2009 · Nov 21, 2008 · TerminatedVARI-STIM III Nerve Locator/Stimulator, Sterile, Medtronic Xomed, Inc. The Vari-Stim III nerve locator/stimulator is a sterile, single-use disposable, hand-held, battery-operated
Other STIMULATOR, NERVE devices
- NIM Vital NIM4CM01Medtronic Xomed, Inc. · STIMULATOR, NERVE2 recalls260 reports
- NIM TriVantage® 8229707Medtronic Xomed, Inc. · STIMULATOR, NERVE2 recalls176 reports
- NIM® 8229306Medtronic Xomed, Inc. · STIMULATOR, NERVE1 recall1 death167 reports
- NIM Vital™ NIM4CPB1Medtronic Xomed, Inc. · STIMULATOR, NERVE3 recalls45 reports
- NIM Trivantage® 8229707Medtronic Xomed, Inc. · STIMULATOR, NERVE1 recall142 reports
- NIM® 8229307Medtronic Xomed, Inc. · STIMULATOR, NERVE1 recall138 reports
- NIM TriVantage® 8229706Medtronic Xomed, Inc. · STIMULATOR, NERVE2 recalls78 reports
- NIM-Response® 8253002Medtronic Xomed, Inc. · STIMULATOR, NERVE171 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page