SYSTEM 1 endoRecalls & reported problems
Corporation Steris Canada · SYSTEM 1 endo Liquid Chemical Sterilant Processing System with Touchscreen is a liquid chemical sterilant processor designed to safely and effectively reprocess heat-sensitive, semi-critical medical devices. · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00724995170554), received between Dec 21, 2022 and May 29, 2025 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Insufficient Device Problem Information2
- Leak/Splash2
- Failure to Align1
- Improper or Incorrect Procedure or Method1
- Mechanical Problem1
Patient problems
- Burn(s)2
- No Clinical Signs, Symptoms or Conditions2
- Upper Respiratory Tract Irritation1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 29, 2025Leak/Splash; Leak/Splash
THE USER FACILITY REPORTED THAT DURING A CYCLE FOR THEIR SYSTEM 1 ENDO, WATER WITH STERILANT LEAKED OUT ONTO THE FLOOR. USER FACILITY PERSONNEL PRESENT IN THE AREA EXPERIENCED "RESPIRATORY ISSUES" AND WENT TO THE EMERGENCY DEPARTMENT. IT IS UNKNOWN IF TREATMENT WAS ADMINISTERED.
Patient problems: Upper Respiratory Tract Irritation
MAUDE report 22103969 ↗MalfunctionMar 27, 2025Failure to Align; Insufficient Device Problem Information; Failure to Align; Insufficient Device Problem Information
THE USER FACILITY REPORTED THAT THEIR SYSTEM 1 ENDO LIQUID CHEMICAL STERILANT PROCESSING SYSTEM WAS LEAKING WATER. NO REPORT OF INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21709181 ↗MalfunctionDec 12, 2024Mechanical Problem; Insufficient Device Problem Information; Mechanical Problem; Insufficient Device Problem Information
THE USER FACILITY REPORTED THAT THEIR SYSTEM 1 ENDO LIQUID CHEMICAL STERILANT PROCESSING SYSTEM WOULD NOT DRAIN PROPERLY AND HAD TROUBLE OPENING THE DOOR. PATIENT PROCEDURES WERE SUBSEQUENTLY POSTPONED. NO REPORT OF INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20919283 ↗MalfunctionFeb 8, 2023Leak/Splash; Leak/Splash
THE USER FACILITY REPORTED THAT DURING A PROCESSING CYCLE FOR THEIR SYSTEM 1 ENDO SYSTEM, THE LID "POPPED" OPENED SUBSEQUENTLY CAUSING LIQUID TO LEAK OUT OF THE UNIT AND ONTO THE FLOOR. USER FACILITY PERSONNEL PROCEEDED TO CLEAN UP THE LIQUID AND IN THE PROCESS EXPERIENCED INHALATION/IRRITATION. ONE OF THE EMPLOYEES OBTAINED A BURN ON HER FOREARM AND SOUGHT AND RECEIVED MEDICAL TREATMENT.
Patient problems: Burn(s)
MAUDE report 16330456 ↗MalfunctionDec 21, 2022Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method
THE USER FACILITY REPORTED THAT AN EMPLOYEE OBTAINED A BURN WHILE HANDLING A CUP OF S40 STERILANT CONCENTRATE. THE EMPLOYEE SOUGHT AND RECEIVED MEDICAL TREATMENT.
Patient problems: Burn(s)
MAUDE report 16028938 ↗
FDA clearance and classification
Cleared through 510(k) K251666 on Apr 8, 2026 (decision: Substantially Equivalent). Submitted by STERIS Corporation as “SYSTEM 1E Liquid Chemical Sterilant Processing System, Model P6700; SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900”. The FDA review took 313 days. FDA record ↗
Cleared through Special 510(k) K232914 on Oct 3, 2023 (decision: Substantially Equivalent). Submitted by STERIS Corporation as “SYSTEM 1E Liquid Chemical Sterilant Processing System (P6500); SYSTEM 1 endo Liquid Chemical Sterilant Processing System (P6800); SYSTEM 1 endo Liquid Chemical Sterilant Processing System (P6900)”. The FDA review took 14 days. FDA record ↗
Cleared through Special 510(k) K230582 on Mar 28, 2023 (decision: Substantially Equivalent). Submitted by STERIS Corporation as “SYSTEM 1 endo Liquid Chemical Sterilant Processing System, Model P6900”. The FDA review took 26 days. FDA record ↗
…and 7 more FDA submissions listed for this device.
The FDA regulates product code MED (sterilant, medical devices) under 21 CFR 880.6885 as a Class II device. 21 CFR 880.6885 ↗
Common questions about the SYSTEM 1 endo
Has the SYSTEM 1 endo been recalled?
No FDA recall record in our data names this exact device identifier (DI 00724995170554), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the SYSTEM 1 endo?
The FDA's MAUDE database lists 5 adverse event reports for this device, received between Dec 21, 2022 and May 29, 2025. In those reports, the most common specific device problems are “Leak/Splash” (2), “Failure to Align” (1) and “Improper or Incorrect Procedure or Method” (1); the most common patient problems are “Burn(s)” (2) and “Upper Respiratory Tract Irritation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the SYSTEM 1 endo?
None of the reports are classified as deaths, 0 as injuries and 5 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the SYSTEM 1 endo FDA approved?
It was cleared through 510(k) K182827 on Jan 31, 2019; its record lists 10 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the SYSTEM 1 endo, and is it still sold?
The FDA's device database lists Corporation Steris Canada as the company responsible for it (brand SYSTEM 1 endo, model 1 endo). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Sterilant, medical devices devices
- Revital-Ox Resert 4455AWSteris Corporation · Sterilant, medical devices1 recall3 reports
- McKesson 341Mckesson Medical-Surgical Inc. · Sterilant, Medical Devices1 recall0 reports
- MetriCide 10-1400Metrex Research, LLC · Sterilant, medical devices1 recall0 reports
- McKesson 68-102800Mckesson Medical-Surgical Inc. · Sterilant, Medical Devices1 recall0 reports
- MetriCide28 10-2800Metrex Research, LLC · Sterilant, medical devices1 recall0 reports
- McKesson 68-101400Mckesson Medical-Surgical Inc. · Sterilant, Medical Devices1 recall0 reports
- CIDEX™ 20390Advanced Sterilization Products Services Inc. · Sterilant, medical devices33 reports
- Rapicide High Level Disinfectant and Sterilant ML02-0059Medivators Inc. · Sterilant, Medical Devices6 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.