Welch Allyn, Inc. 901044Recalls & reported problems

Welch Allyn, Inc. · CUFF WA SOFT ADULT · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00732094188097), received between Sep 14, 2026 and Sep 14, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Failure to Deflate” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Deflate1
  • Inaccurate Information1
  • Material Deformation1

Patient problems

  • Cardiac Arrest1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjurySep 14, 2026Material Deformation; Inaccurate Information; Failure to Deflate

    The customer reported concerns regarding the accuracy of non-invasive blood pressure (NIBP) measurements obtained using disposable FlexiPort soft cuffs. Three days later, the customer provided the following additional information. Reportedly, a patient lost pulses at approximately 0930 and underwent resuscitation efforts. Following placement of an arterial line after the resuscitation, a discrepancy was observed between non-invasive blood pressure (NIBP) cuff readings and arterial line pressure measurements. According to the report, the blood pressure cuff on the patient's arm consistently displayed measurements that were substantially lower than the arterial line readings. As an example, at approximately 1800, the blood pressure cuff reportedly displayed a reading of 64/41 mmHg while the arterial line reading was 105/53 mmHg. The customer further reported that at 1000, 1015, and 1100, the blood pressure cuff continued to display extremely low blood pressure readings when the cuff was not secured around the patient's arm and was reportedly positioned underneath the patient. The customer reported concern that the discrepancy between the NIBP cuff readings and arterial line pressure

    Patient problems: Cardiac Arrest

    MAUDE report 50753166 ↗