GORE-TEX Soft Tissue Patch 1305010020Recalls & reported problems
W. L. Gore & Associates, Inc. · GORE-TEX SOFT TISSUE PATCH 5.0cmX10.0cmX2.0mm · Class 2 · Implant
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00733132600489), received between Jun 12, 2019 and Apr 5, 2023 — classified as 4 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information4
Patient problems
- Abscess2
- No Clinical Signs, Symptoms or Conditions2
- No Code Available2
- Unspecified Infection2
- Adhesion(s)1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryApr 5, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED TO GORE THAT THE PATIENT UNDERWENT OPEN INGUINAL HERNIA REPAIR ON (B)(6) 2017, WHEREBY A GORE-TEX® SOFT TISSUE PATCH WAS IMPLANTED. THE COMPLAINT ALLEGES THAT ON (B)(6) 2021, AN ADDITIONAL PROCEDURE OCCURRED WHEREBY THE GORE DEVICE WAS EXPLANTED. IT WAS REPORTED THE PATIENT ALLEGES THE FOLLOWING INJURIES: INFECTED MESH, EXPLANATION OF MESH. ADDITIONAL EVENT SPECIFIC INFORMATION WAS NOT PROVIDED.
Patient problems: Abscess; Unspecified Infection
MAUDE report 16686530 ↗InjuryJan 18, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED TO GORE THAT THE PATIENT UNDERWENT OPEN LEFT FLANK HERNIA REPAIR ON (B)(6) 2002 WHEREBY A GORE® DUALMESH® BIOMATERIAL WAS IMPLANTED. THE COMPLAINT ALLEGES THAT ON (B)(6) 2005 AN ADDITIONAL PROCEDURE OCCURRED WHEREBY THE GORE DEVICE WAS EXPLANTED. IT WAS REPORTED THE PATIENT ALLEGES THE FOLLOWING INJURIES: INFECTION, HERNIA RECURRENCE, SEROMA, OPEN DRAINING WOUND, SEVERE AND CHRONIC PAIN/DISCOMFORT. ADDITIONAL EVENT SPECIFIC INFORMATION WAS NOT PROVIDED.
Patient problems: Abscess; Unspecified Infection
MAUDE report 16194996 ↗InjuryJun 14, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED TO GORE THAT THE PATIENT UNDERWENT LAPAROSCOPIC INCISIONAL HERNIA REPAIR ON (B)(6) 2006 WHEREBY A GORE-TEX® SOFT TISSUE PATCH WAS IMPLANTED. THE COMPLAINT ALLEGES THAT ON (B)(6) 2008, AN ADDITIONAL PROCEDURE OCCURRED WHEREBY THE GORE DEVICE WAS EXPLANTED. IT WAS REPORTED THE PATIENT ALLEGES THE FOLLOWING INJURIES: ADHESIONS, ADHESIONS TO BOWEL, MESHOMA, SWISS CHEESE DEFECT, SURGERY TO REMOVE MESH, MESH MIGRATION, MESH DETACHMENT. ADDITIONAL EVENT SPECIFIC INFORMATION WAS NOT PROVIDED.
Patient problems: Adhesion(s); No Clinical Signs, Symptoms or Conditions; No Code Available
MAUDE report 8699515 ↗InjuryJun 12, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED TO GORE THAT THE PATIENT UNDERWENT OPEN INCISIONAL HERNIA REPAIR ON (B)(6) 2011 WHEREBY A GORE-TEX® SOFT TISSUE PATCH WAS IMPLANTED. THE COMPLAINT ALLEGES THAT ON (B)(6) 2012, AN ADDITIONAL PROCEDURE OCCURRED WHEREBY THE GORE DEVICE WAS EXPLANTED. IT WAS REPORTED THE PATIENT ALLEGES THE FOLLOWING INJURIES: MESH CONTRACTED INTO A BALL, MESH REMOVAL, MESH FAILURE, ADDITIONAL SURGERY. ADDITIONAL EVENT SPECIFIC INFORMATION WAS NOT PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Code Available
MAUDE report 8691264 ↗
Other Mesh, Surgical, Polymeric devices
- PROCEED PVPMJohnson & Johnson International Inc. · Mesh, surgical, polymeric1,233 reports
- PROCEED PCDN1Johnson & Johnson International Inc. · Mesh, surgical, polymeric744 reports
- PROCEED PCDG1Johnson & Johnson International Inc. · Mesh, surgical, polymeric1 recall1 death637 reports
- PROCEED PVPSJohnson & Johnson International Inc. · Mesh, surgical, polymeric622 reports
- ProGrip LPG1510Sofradim Production · Mesh, surgical, polymeric2 deaths616 reports
- VENTRALEX 0010302Davol Inc. · Mesh, surgical, polymeric4 deaths531 reports
- BARD 0112680Davol Inc. · Mesh, surgical, polymeric1 death494 reports
- ProGrip TEM1509GSofradim Production · Mesh, surgical, polymeric3 deaths471 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.