GORE HELEX Septal Occluder HX2030Recalls & reported problems
W. L. Gore & Associates, Inc. · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00733132607006), received between May 20, 2019 and Nov 25, 2019 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Fracture1
Patient problems
- No Known Impact Or Consequence To Patient1
- Stroke/CVA1
- Thrombus1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 25, 2019Fracture; Fracture
IT WAS REPORTED A GORE® HELEX SEPTAL OCCLUDER WAS IMPLANTED TO CLOSE AN ATRIAL SEPTAL DEFECT (ASD) ON (B)(6) 2014. ON AN UNRELATED FOLLOW-UP EXAM TO ASSESS A SURGICAL MITRAL VALVE REPAIR, A WIRE FRACTURE WAS NOTED ON THE LEFT DISC OF THE HELEX DEVICE. IT WAS ALSO NOTED THAT THE LOCK LOOP WAS NOT CAPTURING THE RIGHT EYELET OF THE DEVICE AND A SIGNIFICANT SHUNT WAS OBSERVED. THE PHYSICIAN SAID THAT DURING THE FUTURE SURGICAL PROCEDURE FOR THE MITRAL VALVE REPAIR, THE DEVICE WILL BE REMOVED AND THE ASD WILL BE SURGICALLY CLOSED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9370584 ↗InjuryMay 20, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THE PHYSICIAN IMPLANTED A 30MM GORE® HELEX® SEPTAL OCCLUDER ON (B)(6) 2014 TO CLOSE A PATENT FORAMEN OVALE. IN (B)(6) 2018, THE PATIENT PRESENTED WITH A STROKE AND ECHOCARDIOGRAPHY DEMONSTRATED A 7MM MASS ON THE LEFT ATRIAL DISC OF THE HELEX® DEVICE. THE PATIENT WAS PLACED ON COUMADIN.
Patient problems: Stroke/CVA; Thrombus
MAUDE report 8624550 ↗
Other Transcatheter Septal Occluder devices
- Amplatzer™ Septal OccluderAga Medical Corporation · Transcatheter septal occluder294 reports
- Amplatzer™ Septal OccluderAga Medical Corporation · Transcatheter septal occluder1 death213 reports
- Amplatzer™ Talisman™ 9-PFO-3025St. Jude Medical, Inc. · Transcatheter septal occluder1 death193 reports
- GORE CARDIOFORM Septal Occluder GSX0030AW. L. Gore & Associates, Inc. · Transcatheter Septal Occluder1 recall143 reports
- Amplatzer™ 9-ASD-MF-025St. Jude Medical, Inc. · Transcatheter septal occluder1 death183 reports
- Amplatzer™ PFO OccluderSt. Jude Medical, Inc. · Transcatheter septal occluder1 death153 reports
- Amplatzer™ 9-ASD-MF-030St. Jude Medical, Inc. · Transcatheter septal occluder149 reports
- Amplatzer™ Talisman™ 9-PFO-2518St. Jude Medical, Inc. · Transcatheter septal occluder139 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page