GORE EXCLUDER AAA Endoprosthesis PXT281212Recalls & reported problems
W. L. Gore & Associates, Inc. · Class 3 · Implant
All models of GORE EXCLUDER AAA Endoprosthesis (81)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00733132610259), received between May 26, 2023 and Jun 1, 2023 — classified as 2 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).
2 other recalls cover devices cleared under the same FDA submission (P020004); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information1
- Patient-Device Incompatibility1
Patient problems
- Aneurysm2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJun 1, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
ON (B)(6) 2010, THIS PATIENT UNDERWENT AN ENDOVASCULAR TREATMENT FOR AN ABDOMINAL AORTIC ANEURYSM USING GORE® EXCLUDER® AAA ENDOPROSTHESIS. A TRUNK - IPSILATERAL LEG ENDOPROSTHESIS (PXT281212) WAS DEPLOYED, AND ITS IPSILATERAL LEG WAS EXTENDED BY A CONTRALATERAL LEG ENDOPROSTHESIS (PXC181000). ANOTHER CONTRALATERAL LEG ENDOPROSTHESIS (PXC201400) WAS DEPLOYED AS A CONTRALATERAL LIMB. AS THE PXC201400 LANDED ON A TIGHTLY CURVED LEFT COMMON ILIAC ARTERY, IT WAS REINFORCED BY A CORDIS PALMAZ® STENT. THE FINAL ANGIOGRAPHY CONFIRMED A TYPE ENDOLEAK, WHICH WAS DECIDED TO BE MONITORED AND LEFT UNTREATED. THE PATIENT TOLERATED THE PROCEDURE. (REF. (B)(4)) ON (B)(6) 2015, REINTERVENTION WAS PERFORMED TO TREAT A PROXIMAL TYPE ENDOLEAK. WHILE SECURING THE LEFT RENAL FLOW BY USING A BOSTON SCIENTIFIC EXPRESS¿ VASCULAR SD AS A CHIMNEY GRAFT, AN AORTIC EXTENDER ENDOPROSTHESIS WAS ADDED TO THE PROXIMAL END OF THE PREVIOUSLY IMPLANTED PXT281212. THE FINAL ANGIOGRAPHY CONFIRMED NO ENDOLEAKS. THE PATIENT TOLERATED THE PROCEDURE. (REF. (B)(4)) ON AN UNKNOWN DATE AROUND 2021, A FOLLOW-UP EXAMINATION CONFIRMED AN UNKNOWN AMOUNT OF ANEURYSM ENLARGEMENT. AS TREATMENT, THE PATIENT UNDERWENT AN OPEN VASCULA
Patient problems: Aneurysm
MAUDE report 17037059 ↗InjuryMay 26, 2023Patient-Device Incompatibility; Patient-Device Incompatibility
ON (B)(6) 2010, THIS PATIENT UNDERWENT AN ENDOVASCULAR TREATMENT FOR AN ABDOMINAL AORTIC ANEURYSM USING GORE® EXCLUDER® AAA ENDOPROSTHESIS. A TRUNK - IPSILATERAL LEG ENDOPROSTHESIS (PXT281212) WAS DEPLOYED, AND ITS IPSILATERAL LEG WAS EXTENDED BY A CONTRALATERAL LEG ENDOPROSTHESIS (PXC181000). ANOTHER CONTRALATERAL LEG ENDOPROSTHESIS (PXC201400) WAS DEPLOYED AS A CONTRALATERAL LIMB. AS THE PXC201400 LANDED ON A TIGHTLY CURVED LEFT COMMON ILIAC ARTERY, IT WAS REINFORCED BY A CORDIS PALMAZ® STENT. THE FINAL ANGIOGRAPHY CONFIRMED A TYPE ENDOLEAK, WHICH WAS DECIDED TO BE MONITORED AND LEFT UNTREATED. THE PATIENT TOLERATED THE PROCEDURE. (REF. MPDCASE-(B)(4)) ON (B)(6) 2015, REINTERVENTION WAS PERFORMED TO TREAT A PROXIMAL TYPE ENDOLEAK. WHILE SECURING THE LEFT RENAL FLOW BY USING A BOSTON SCIENTIFIC EXPRESS¿ VASCULAR SD AS A CHIMNEY GRAFT, AN AORTIC EXTENDER ENDOPROSTHESIS WAS ADDED TO THE PROXIMAL END OF THE PREVIOUSLY IMPLANTED PXT281212. THE FINAL ANGIOGRAPHY CONFIRMED NO ENDOLEAKS. THE REPORTING PHYSICIAN STATED THAT THE PROXIMAL TYPE I ENDOLEAK WAS PREDICTABLE AS THE PATIENTS¿ INFRARENAL NECK LENGTH WAS SHORT AND THE PROXIMAL LANDING ZONE WAS SHORTER THAN WHAT WAS REQUIRED IN THE
Patient problems: Aneurysm
MAUDE report 17008916 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P020004. One submission often covers many models, so check the product and lot details in each record.
- Z-0996-2020 · Jan 6, 2020 · TerminatedGORE EXCLUDER Iliac Branch Endoprosthesis (IBE)
- Z-0995-2020 · Jan 6, 2020 · TerminatedGORE EXCLUDER AAA Endoprosthesis
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page