- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00733132613618), received between Jun 25, 2020 and Jun 25, 2020 — classified as 1 injury.
6 other recalls cover devices cleared under the same FDA submission (P040043); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Vascular Dissection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 25, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON (B)(6) 2012, THIS PATIENT UNDERWENT TREATMENT FOR A DISSECTING THORACIC AORTIC ANEURYSM. A TOTAL ARCH REPLACEMENT (TAR) PROCEDURE AND OPEN STENT PROCEDURE WAS PERFORMED, AND TWO GORE® TAG® THORACIC ENDOPROSTHESES WERE IMPLANTED. THE PATIENT TOLERATED THE PROCEDURE. ON MAY 15, 2020, FOLLOW-UP COMPUTED TOMOGRAPHY IDENTIFIED A DISSECTION FROM THE DISTAL END OF THE GORE® TAG® THORACIC ENDOPROSTHESIS AND THE LEAK FROM THE ANASTOMOSIS SITE OF THE RECONSTRUCTED THE LEFT COMMON CAROTID ARTERY IN THE TAR PROCEDURE (OUTSIDE OF THE GORE® TAG® TREATMENT AREA). 3D RECONSTRUCTION ILLUSTRATING BOTH PROXIMAL AND DISTAL FALSE LUMEN PROFUSION. 3D RECONSTRUCTION ILLUSTRATING CONTRAST POOLING AROUND THE LSA AND THE LCCA. 3D RECONSTRUCTION ILLUSTRATING FALSE LUMEN PERFUSION. ON (B)(6) 2020, THE PATIENT UNDERWENT A REINTERVENTION USING GORE® TAG® CONFORMABLE THORACIC STENT GRAFT WITH ACTIVE CONTROL® SYSTEM. FIRST, A LEFT AXILLARY ARTERY ¿ RIGHT AXILLARY ARTERY ¿ LEFT COMMON CAROTID ARTERY BYPASS PROCEDURE WAS PERFORMED. THEN, A TGMR373715J WAS IMPLANTED PROXIMALLY OF THE PREVIOUS IMPLANTED TAG® DEVICE TO SOLVE THE LEAK FROM THE ANASTOMOSIS SITE OF THE RECONSTRUCTED LEFT COMMON CAROTID ARTERY. THEN A
Patient problems: Vascular Dissection
MAUDE report 10197406 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P040043. One submission often covers many models, so check the product and lot details in each record.
- Z-0290-2021 · Sep 9, 2020 · Open, ClassifiedGORE TAG CONFORMABLE Thoracic Stent Graft with ACTIVE CONTROL System
- Z-0291-2021 · Sep 9, 2020 · Open, ClassifiedGORE TAG Conformable Thoracic Stent Graft with ACTIVE CONTROL System
- Z-2052-2020 · Dec 17, 2019 · TerminatedConformable Thoracic Stent Graft, Rx only, Sterile EO - Product Usage: This device is intended for endovascular repair of lesions of the descending thoracic aorta.
- Z-0048-2018 · Sep 25, 2017 · TerminatedGORE TAG, THORACIC ENDOPROSTHESIS, CONFORMABLE. The GORE TAG Thoracic Endoprosthesis is intended for endovascular repair of all lesions of the descending thoracic aorta.
- Z-1236-06 · Apr 28, 2006 · TerminatedGORE TAG THORACIC ENDOPROSTHESIS System, Endovascular Graft, Aortic Aneurysm Treatment, Catalogue Number TG3410, 34mm x 10cm
- Z-1237-06 · Apr 28, 2006 · TerminatedGORE TAG THORACIC ENDOPROSTHESIS System, Endovascular Graft, Aortic Aneurysm Treatment, Catalogue Number TG3415, 34mm x 15cm
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page