GORE-TEX Suture 6M02Recalls & reported problems

W. L. Gore & Associates, Inc. · GORE-TEX SUTURE CV-6 76cm DoubleArm TTc-9-1dz · Class 2 · Implant

All models of GORE-TEX Suture (19)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00733132629329), received between Feb 11, 2020 and Aug 14, 2024 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Material Frayed” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Frayed2
  • Fracture1

Patient problems

  • No Known Impact Or Consequence To Patient2
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 14, 2024Fracture; Fracture

    IT WAS REPORTED TO GORE THAT ON (B)(6) 2024, A PATIENT WAS TO BE USED WITH GORE-TEX® SUTURE (6M02A)) DURING PROCEDURE. THE SUTURE AIMED TO SUTURE VASCULAR GRAFT (GORE, RRT08070070L). BUT THE SUTURE WAS BROKEN IMMEDIATELY WHEN PHYSICIAN WAS ATTEMPTING TO SLIP THE KNOB AFTER PUNCTURING THE VASCULAR GRAFT. ANOTHER SUTURE OF SAME MODEL WAS USED TO SUCCESSFULLY COMPLETE THE SURGERY. THE PATIENT'S CONDITION REMAINED STABLE AFTER SURGERY WITHOUT ANY ADVERSE REACTIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19979086 ↗
  • MalfunctionFeb 11, 2020Material Frayed; Material Frayed

    IT WAS REPORTED TO GORE THAT DURING CAROTID CASES USING GORE-TEX® SUTURE, SEVERAL SUTURES FRAYED. NO PATIENT HARM WAS REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9694207 ↗
  • MalfunctionFeb 11, 2020Material Frayed; Material Frayed

    IT WAS REPORTED TO GORE THAT DURING CAROTID CASES USING GORE-TEX® SUTURE, SEVERAL SUTURES FRAYED. NO PATIENT HARM WAS REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9694197 ↗

Other SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE devices