GORE TAG Thoracic Branch Endoprosthesis TE3140ARecalls & reported problems

W. L. Gore & Associates, Inc. · TAG TBE THORACIC AORTIC EXT 31mmX4.0cm 4mm · Class 3 · Implant

All models of GORE TAG Thoracic Branch Endoprosthesis (30)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00733132654307), received between Feb 23, 2023 and Apr 25, 2025 — classified as 3 injuries.

The most frequently reported specific device problem is “Positioning Problem” (2 reports).

1 other recall cover devices cleared under the same FDA submission (P210032); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Problem2
  • Malposition of Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Obstruction/Occlusion1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 25, 2025Positioning Problem; Positioning Problem

    THE FOLLOWING WAS REPORTED TO GORE: ON (B)(6) 2025, THE PATIENT WAS IMPLANTED WITH A GORE® TAG® THORACIC BRANCH ENDOPROSTHESIS AORTIC EXTENDER IN THE ASCENDING AORTA TO COVER THE DISTAL ANASTOMOSIS FROM A PREVIOUS CORONARY ARTERY BYPASS GRAFT OPEN REPAIR. REPORTEDLY THE CORONARY ARTERY BYPASS OPEN REPAIR OCCURRED APPROXIMATELY A MONTH AGO. THE PROXIMAL LUMEN OF THE ARTERY DIAMETER WAS 24-26 MM AND THE DISTAL LUMEN OF THE ARTERY DIAMETER WAS 10 MM. THE DISTAL AREA WAS CAUSING A STRICTURE IN THE ARTERY. IT WAS REPORTED THAT AFTER THE GORE® TAG® THORACIC BRANCH ENDOPROSTHESIS AORTIC EXTENDER WAS DEPLOYED, THERE WAS SOME RESISTANCE IN REMOVING THE DELIVERY CATHETER. SOME FORCE WAS USED TO REMOVE THE DELIVERY CATHETER AND WHILE DOING SO THE GRAFT WAS PULLED DOWN APPROXIMATELY 5 TO 6 MM. THIS CAUSED PARTIAL COVERAGE OF THE INNOMINATE ARTERY. THE PHYSICIAN CHOSE TO USE A BARE METAL STENT IN THIS AREA. THE BARE METAL STENT WAS DEPLOYED IN THE INNOMINATE ARTERY GOING INTO THE RIGHT COMMON CAROTID ARTERY, DUE TO THE INNOMINATE ARTERY BEING SHORT (2 CM). THE PATIENT TOLERATED THE PROCEDURE. IT IS UNKNOWN WHAT CAUSED THE DEVICE TO MOVE AFTER DEPLOYMENT. THE OLIVE MAY HAVE CAUGHT ON THE EDGE OF

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21912669 ↗
  • InjuryMay 14, 2024Positioning Problem; Positioning Problem

    THE FOLLOWING WAS REPORTED TO GORE: ON FRIDAY (B)(6) 2024, THE PATIENT HAD A CAROTID TO LEFT SUBCLAVIAN BYPASS TO TREAT A PSEUDOANEURYSM ON THE INNER CURVE OF THE AORTA. ON FRIDAY (B)(6) 2024, THE PATIENT WAS FURTHER TREATED FOR THE PSEUDOANEURYSM WITH GORE® TAG® THORACIC BRANCH ENDOPROSTHESES, WITH THE BRANCH GOING INTO THE LEFT SUBCLAVIAN. AFTER DEPLOYMENT, IT WAS DETERMINED THAT THEY NEEDED TO EXTEND PROXIMALLY WITH AN AORTIC EXTENDER. AFTER DEPLOYING THE EXTENDER, THE ANGIOGRAPHY SHOWED THAT THE INNOMINATE ARTERY WAS COVERED 30-40%. THE PHYSICIAN ADVANCED A CODA BALLOON ON THE DIAGNOSTIC WIRE FROM THE PIGTAIL, WHICH HAD BEEN LOCATED DISTAL OF THE EXTENDER. THE BALLOON WAS USED IN AN ATTEMPT TO DISLODGE THE EXTENDER AND MOVE IT DISTALLY, BUT THIS ATTEMPT FAILED. THE PHYSICIAN THEN ATTEMPTED TO USE A SNARE TO PULL THE EXTENDER CUFF DISTALLY. HOWEVER, WHEN THIS WAS ATTEMPTED, THE EXTENDER MIGRATED QUICKLY PROXIMALLY, LANDING IN THE ASCENDING AORTA. THIS MIGRATION RESOLVED THE PREVIOUS COVERAGE ISSUE; HOWEVER, THE EXTENDER DID NOT HAVE APPOSITION AGAINST THE VESSEL. BECAUSE THE EXTENDER WAS HIGHLY LIKELY TO MIGRATE, A BARE METAL STENT WAS INSERTED TO PIN THE EXTENDER AGAINST THE VE

    Patient problems: Obstruction/Occlusion

    MAUDE report 19310702 ↗
  • InjuryFeb 23, 2023Malposition of Device; Malposition of Device

    ON (B)(6) 2023, THE PATIENT WAS TREATED FOR A THORACIC AORTIC ANEURYSM. THE PHYSICIAN IMPLANTED A GORE® TAG® THORACIC BRANCH ENDOPROSTHESIS. THE DEVICE PARTIALLY COVERED THE CAROTID ARTERY. THY PHYSICIAN CUT DOWN AND STENTED THE CAROTID. THE PHYSICIAN IS UNSURE WHY THE CAROTID WAS PARTIALLY COVERED. THE PATIENT TOLERATED THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16427937 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P210032. One submission often covers many models, so check the product and lot details in each record.

  • Z-2672-2026 · May 19, 2026 · Open, Classified
    GORE TAG Thoracic Branch Endoprosthesis Side Branch Component Catalog Numbers (by Region) United States (includes Puerto Rico) and Canada: TSB080806A, TSB081006A, TSB081206A, TSB08

Other System, Endovascular Graft, Aortic Aneurysm Treatment devices

All System, Endovascular Graft, Aortic Aneurysm Treatment devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page