The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00749756113427), received between Dec 16, 2025 and Dec 19, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Material Puncture/Hole” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Material Puncture/Hole2
- Device Dislodged or Dislocated1
Patient problems
- Laceration(s)1
- Needle Stick/Puncture1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 19, 2025Device Dislodged or Dislocated
ON [REDACTED], THE PEDIATRIC PATIENT HAD THE ELBOW POSITIONER/IMMOBILIZER IN PLACE ON THE PATIENT'S LEFT ARM IN ORDER TO PROVIDE PROTECTION FOR THE INTRAVENOUS PICC [PERIPHERALLY INSERTED CENTRAL CATHETER] LINE AND DRESSING. WHILE REPOSITIONING THE PATIENT, THE NURSE NOTED THAT THE METAL ROD HAD DISLODGED FROM THE CLOTH COVERING AND WAS DIGGING INTO THE PATIENT'S UNDERARM CAUSING A PUNCTURE WOUND. (THERE WAS ALSO AN EARLIER REPORT OF THE SAME PRODUCT ALSO DISLODGING FROM THE CLOTH COVERING BUT NO INJURY WAS NOTED WITH THAT FIRST ONE - THAT PRODUCT WAS ALSO DISCARDED). THE PATIENT'S LEFT AXILLA INJURY SITE ASSESSED BY THE PEDIATRIC SURGERY NURSE PRACTITIONER, CLEANSED WITH NORMAL SALINE AND PACKED WITH A WICK DRESSING AND MEPILEX APPLIED. DAILY WOUND CARE PROVIDED.
Patient problems: Needle Stick/Puncture
MAUDE report 23849852 ↗MalfunctionDec 16, 2025Material Puncture/Hole; Material Puncture/Hole
A USER FACILITY REPORTED, "THIS PATIENT HAD WELCOME SLEEVES ON FOR IV PROTECTION. DURING A REPOSITION, THIS RN NOTED THAT THE METAL BAR HAD PUNCTURED THROUGH THE WELCOME SLEEVE. WELCOME SLEEVE WAS THROWN AWAY, SKIN CHECK COMPLETED WITH NO SIGNS OF INJURY AT THIS TIME AND A NEW WELCOME SLEEVE WAS PLACED."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23815361 ↗MalfunctionDec 16, 2025Material Puncture/Hole; Material Puncture/Hole
A USER FACILITY REPORTED, "PATIENT HAD ELBOW IMMOBILIZER ON L ARM TO PROTECT PICC LINE/DRESSING. PATIENT IS VERY CONTRACTED AND MOVES FREQUENTLY. ON REMOVAL OF ELBOW IMMOBILIZER, IT WAS NOTED THAT METAL ROD HAD DISLODGED FROM CLOTH COVERING AND WAS DIGGING INTO PATIENT'S UNDERARM CAUSING PUNCTURE WOUND."
Patient problems: Laceration(s)
MAUDE report 23815360 ↗
Other Restraint, protective devices
- DeRoyal M8138Deroyal Industries, Inc. · Restraint, protective1 recall1 report
- DeRoyal M8125Deroyal Industries, Inc. · Restraint, protective1 recall0 reports
- DeRoyal M8137Deroyal Industries, Inc. · Restraint, protective1 recall0 reports
- DeRoyal M8136Deroyal Industries, Inc. · Restraint, protective1 recall0 reports
- DeRoyal M8124Deroyal Industries, Inc. · Restraint, protective1 recall0 reports
- POSEY 2532Posey Products, LLC · Restraint, Protective36 reports
- POSEY 2551Posey Products, LLC · Restraint, Protective14 reports
- POSEY 2799Posey Products, LLC · Restraint, Protective9 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page