N/A 42314Recalls & reported problems
Medtronic Ps Medical, Inc. · VALVE 42314 SM CONTOURED MED PRESS IMP · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00763000028015), received between Jul 7, 2025 and Sep 11, 2026 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (2 reports).
2 other recalls cover devices cleared under the same FDA submission (K841442); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Fluid/Blood Leak2
- Infusion or Flow Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- Thrombosis/Thrombus1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 11, 2026Fluid/Blood Leak
Medtronic received information regarding a valve. It was reported that the proximal valve stem was leaking during a ventriculoperitoneal shunt placement. This was used on the patient but removed and replaced when it was noted to be leaking. The date of surgery was (b)(6)2026.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50734639 ↗MalfunctionJan 23, 2026Fluid/Blood Leak
MEDTRONIC RECEIVED INFORMATION REGARDING A VALVE. IT WAS REPORTED THAT THE DOCTOR WAS PLACING VENTRICULOPERITONEAL SHUNT, HOWEVER, IT STARTED LEAKING AS SOON AS THEY PUT IT IN. THE DOCTOR REMOVED IT AND PLACED A NEW ONE WITHOUT PROBLEM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24160260 ↗InjuryJul 7, 2025Infusion or Flow Problem; Infusion or Flow Problem
MEDTRONIC RECEIVED INFORMATION REGARDING A SHUNT. IT WAS REPORTED THE PATIENT WAS RECOVERING FROM A BRAIN TUMOR (MEDULLOBLASTOMA). IT WAS STATED THE DEVICE WAS EXTERNALIZED AS THE PATIENT WAS GOING THROUGH RADIOTHERAPY. THEY WERE GOING TO INTERNALIZE IT MAYBE ON (B)(6) 2025. THIS WAS CLARIFIED INDICATING THAT THE SHUNT WAS STILL IN PLACE AND THAT THE EXIT WAS OUT OF THE ABDOMEN TO A BAG. IT WAS INDICATED THE PATIENT HAD CEREBRAL MUTISM AND WAS UNABLE TO COMMUNICATE BUT SOMETIMES MAYBE SLIGHT HEAD NOD TO YES/NO QUESTIONS. THE PATIENT WAS ALSO HAVING PROBLEMS WITH OVER OR UNDER DRAINING AS THEY WERE HAVING SLIT VENTRICLES, THEN HUGE VENTRICLES. THEY HAVE NOT FOUND A DECENT DRAIN OPEN SCHEDULE. IT WAS INDICATED THAT THE PATIENT HAS HAD MULTIPLE POST OPERATIVE PROBLEMS. 10 WEEKS AFTER THE MEDULLOBLASTOMA WAS REMOVED, THE PATIENT WAS STILL MINIMALLY RESPONSIVE. EVERY CT SCAN SHOWED ENLARGED OR SLIT VENTRICLES. THE PATIENT NOW HAD MULTIPLE BLOOD CLOTS IN THEIR CEREBRAL VESSELS.
Patient problems: Thrombosis/Thrombus
MAUDE report 22418507 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K841442. One submission often covers many models, so check the product and lot details in each record.
- Z-1117-2021 · Jan 11, 2021 · Open, ClassifiedMedtronic PS Medical Cerebro Spinal Fluid (CSF)-Flow Control Valves for the following CFNs: 22011 L- SHUNT 22011 L INTL ONLY ULTRA SM LOW 22011 LL - SHUNT 22011 LL INTL ONLY
- Z-0397-2014 · Nov 18, 2013 · TerminatedCSF-Unitized Shunt, Contoured Regular, Low Pressure, Catalog No. 46022; CSF-Unitized Shunt, Contoured Regular, Medium Pressure, Catalog No. 46024; CSF-Unitized Shunt, Contoured Reg
Other Shunt, central nervous system and components devices
- NATUS EDS3 DRAINAGE SYSTEM NT821731CNatus Medical Incorporated · Shunt, Central Nervous System And Components1 recall208 reports
- Exacta™ 46700Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall2 deaths163 reports
- Strata® 42866Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 death160 reports
- proGAV 2.0® FX410TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components119 reports
- PROGAV 2.0 FX643TAesculap AG · Shunt, central nervous system and components100 reports
- Becker® 46128Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall50 reports
- M.BLUE PLUS FX804TAesculap AG · Shunt, central nervous system and components82 reports
- proSA® FV701TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components82 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page