Skip to content

KYPHON Xpander II KyphoPak Tray KPX153PBRecalls & reported problems

Medtronic Sofamor Danek, Inc. · BONE TAMP KIT KPX153PB FF X2 15/3 1 STP · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000031565), received between Feb 24, 2025 and Apr 3, 2025 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Mechanical Jam” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Mechanical Jam2
  • Product Quality Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 3, 2025Mechanical Jam; Mechanical Jam

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY FOR VERTEBRAL COMPRESSION FRACTURE L2. IT WAS REPORTED THAT THE BALLOON WAS VERY HARD TO PULL OUT, REQUIRING SIGNIFICANT EFFORT BY THE PHYSICIAN, ALTHOUGH IT EVENTUALLY CAME OUT. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH THE ORIGINAL PRODUCT. NO PATIENT SYMPTOMS OR COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21759837 ↗
  • MalfunctionFeb 24, 2025Product Quality Problem; Mechanical Jam; Product Quality Problem; Mechanical Jam

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY FOR L1 COMPRESSION FRACTURE. IT WAS REPORTED THAT DURING AN INTRA-OPERATIVE PROCEDURE, A BALLOON WAS INFLATED AND GOT STUCK IN THE CANNULA WHEN ATTEMPTING TO REMOVE IT. ADDITIONALLY, THE BALLOON FAILED TO GO BACK UP THE CANNULA AFTER BEING DEFLATED. THE ISSUE OCCURRED DURING THE FIRST INSERTION ATTEMPT INTO THE VERTEBRAL BODY. DESPITE THESE PROCEDURAL ISSUES, THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH THE ORIGINAL PRODUCT, AND THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT. THERE WAS A DELAY IN THE OVERALL PROCEDURE TIME, BUT NO ADDITIONAL TREATMENT OR SURGERY WAS NECESSARY. ADDITIONAL INFORMATION WAS RECEIVED VIA MANUFACTURER REPRESENTATIVE THAT THE PROCEDURE INVOLVED IN THE EVENT WAS KYPHOPLASTY. IT IS UNKNOWN IF THE REPORTED ISSUE IS A MANUFACTURING ISSUE OR HAPPENED DURING NORMAL USE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21444032 ↗

Other TAMP devices

All TAMP devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page