The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000031626), received between Mar 20, 2024 and Mar 16, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Difficult to Insert” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Insert1
  • Material Rupture1

Patient problems

  • Device Embedded In Tissue or Plaque1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 16, 2026Difficult to Insert

    ADDITIONAL INFORMATION RECEIVED THAT DEVICE USED FOR KYPHOPLASTY PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24602693 ↗
  • MalfunctionMar 20, 2024Material Rupture; Material Rupture

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING KYPHOPLASTY FOR T12 VERTEBRAL COMPRESSION. IT WAS REPORTED THAT THE DOCTOR ACCESSED THE LEVEL OF THE VERTEBRAL COMPRESSION T12 ACCORDING TO THE INSTRUCTIONS USING THE LEFT PEDICLE ONLY. HE THEN DEPLOYED A SINGLE BALLOON THROUGH THE ACCESS PORT AND ASKED FOR THE CEMENT TO BE MIXED. WHEN THE CEMENT WAS DETERMINED TO BE READY TO INJECT, THE DOCTOR INJECTED ABOUT 1CC OF CEMENT, THEN RETRACTED THE BONE FILLER DEVICE, AND PROCEEDED TO USE THE CURETTE TO SPREAD THE CEMENT OUTWARD FROM ITS ORIGINAL POINT OF INJECTION. THEN HE REMOVED THE CURETTE, AND REINSERTED THE BALLOON CATHETER INTO THE WORKING CANNULA TO FURTHER SPREAD THE CEMENT AND IMPACT INTO THE VERTEBRAL BODY BONE. UPON DOING SO, HE NOTICED THE BALLOON HAD BROKEN. HE NOTED HE HAD FILLED THE BALLOON WITH 2CC OF CONTRAST AND UP TO 100PSI OF PRESSURE. HE THEN DREW BACK ON THE INFLATION SYRINGE HANDLE TO REMOVE AS MUCH OF THE CONTRAST AS POSSIBLE, THEN PULLED OUT THE BALLLOON CATHER. UPON DOING SO HE NOTICED THE LEAD HALF OF THE BALLOON HAD NOT COME OUT. HE THEN ATTEMPTED TO RETRIEVE THE FRONT HALF OF THE BALLOON USING

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 18938824 ↗