Valiant Navion™ VNMF4646C62TU (UDI 00763000100780)Recalls & reported problems
Medtronic, Inc. · STENT GRAFT VNMF4646C62TU VAL NAV FF · Class 3 · Implant
All models of Valiant Navion (137)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00763000100780), received between Apr 24, 2019 and Jun 17, 2022 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Leak/Splash” (2 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Feb 12, 2021Class IOpen, Classified
Due to the presence of type IIIb endoleaks, stent fractures, and stent ring enlargement.
Z-1201-2021 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Leak/Splash2
- Adverse Event Without Identified Device or Use Problem1
- Malposition of Device1
Patient problems
- Injury1
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 17, 2022Leak/Splash; Adverse Event Without Identified Device or Use Problem; Leak/Splash; Adverse Event Without Identified Device or Use Problem
A VALIANT NAVION WAS IMPLANTED FOR THE TREATMENT OF A FUSIFORM ANEURYSM OF AN UNKNOWN SIZE. IT WAS REPORTED THE PATIENT RETURNED FOR A FOLLOW-UP CT APPROXIMATELY 1 YEAR LATER AND A TYPE IA ENDOLEAK AND AORTIC ENLARGEMENT WERE IDENTIFIED. THE PATIENT EXPIRED ON THE FOLLOWING DAY . NO CAUSE OF THE ENDOLEAK AS PER THE PHYSICIAN WAS PROVIDED. AS PER THE PHYSICIAN THE CAUSE OF DEATH WAS NOT AORTIC-RELATED. NO ADDITIONAL CLINICAL SEQUELAE WAS PROVIDED AND THE PATIENT HAS EXPIRED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14729957 ↗InjuryJan 16, 2020Leak/Splash; Leak/Splash
A VALIANT NAVION STENT GRAFT WAS IMPLANTED FOR THE ENDOVASCULAR TREATMENT OF A UNKNOWN SIZED THORACIC AORTIC ANEURYSM. IT WAS REPORTED THAT APPROXIMATELY 6 WEEKS LATER WHEN THE PATIENT RETURNED FOR FOLLOW-UP A CT SHOWED A TYPE IA ENDOLEAK. A SECONDARY PROCEDURE WAS CARRIED OUT ON THE SAME DATE AND A VALIANT NAVION (VNMF4646C62TU) WAS PLACED BELOW THE RENAL ARTERY ALONG WITH APTUSENDOANCHORS. ON FINAL ANGIOGRAM THE ENDOLEAK HAD RESOLVED. AS PER THE PHYSICIAN THE CAUSE OF THE EVENT CAN NOT BE DETERMINED. NO ADDITIONAL CLINICAL SEQUALAE WERE PROVIDED AND THE PATIENT IS FINE.
Patient problems: Injury
MAUDE report 9595479 ↗MalfunctionApr 24, 2019Malposition of Device; Malposition of Device
A VALIANT NAVION STENT GRAFT SYSTEM WAS IMPLANTED IN A PATIENT FOR THE ENDOVASCULAR TREATMENT OF A 53MM DIAMETER ABDOMINAL AORTIC ANEURYSM. IT WAS NOTED THAT THE PATIENT HAD PREVIOUSLY HAD A GORE STENT GRAFT IMPLANTED WHICH HAD MIGRATED DUE TO DISEASE PROGRESSION. IT WAS OBSERVED THAT THE AORTA MEASURED 41MM JUST BELOW THE RENALS. MILD VESSEL CALCIFICATION WAS NOTED. IT WAS REPORTED THAT DURING DEPLOYMENT OF THE CUFF, THE GRAFT MIGRATED PROXIMALLY ABOUT 2CM COVERING BOTH RENAL ARTERIES. AT THIS POINT THE BARE STENTS HAD NOT BEEN DEPLOYED AND SO THE GRAFT WAS ABLE TO BE PULLED DOWN TO BELOW THE RENALS TO ALLOW RENAL PERFUSION. A SECOND VALIANT NAVION COVERED SEAL 46MM GRAFT WAS PLACED BELOW THE RENAL ARTERIES TO BRIDGE THE GAP BETWEEN THE FIRST NAVION AND THE ORIGINAL GORE GRAFT. 6 HELI-FX ENDOANCHORS WERE PLACED TO PREVENT THE STENT GRAFT FROM RIDING UP. ON FINAL ANGIOGRAM, BOTH RENAL ARTERIES WERE PERFUSED AND NO ENDOLEAK WAS SEEN. POST OP DAY ONE THE PATIENT HAS GOOD KIDNEY FUNCTION AND DOING WELL PER THE PHYSICIAN. AS PER THE PHYSICIAN, THE CAUSE OF THE EVENT IS UNKNOWN BUT COMMENTED THE CUFF PERFORMED DIFFERENTLY THAN EXPECTED BY JUMPING UP TO 2CM WITH DOWNWARD PRESSURE. NO ADD
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8543381 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page