Valiant Navion™ VNMC2525C180TU (UDI 00763000100940)Recalls & reported problems
Medtronic, Inc. · STENT GRAFT VNMC2525C180TU VAL NAV CS · Class 3 · Implant
All models of Valiant Navion (137)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 4
- Deaths reported
- 1
- Injuries reported
- 3
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00763000100940), received between Mar 11, 2022 and Jan 23, 2023 — classified as 1 death, 3 injuries.
The most frequently reported specific device problem is “Leak/Splash” (3 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Recalls naming this device
- Feb 12, 2021Class IOpen, Classified
Due to the presence of type IIIb endoleaks, stent fractures, and stent ring enlargement.
Z-1201-2021 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Leak/Splash3
- Adverse Event Without Identified Device or Use Problem2
- Material Deformation1
Patient problems
- Insufficient Information2
- Vascular Dissection2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
DeathJan 23, 2023Leak/Splash; Leak/Splash
A VALIANT NAVION STENT GRAFT WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A THORACIC AORTIC DISSECTION ON THE (B)(6) 2020. ADDITIONAL NON MDT DEVICES WERE ALSO IMPLANTED (ADDITIONAL DEVICES DISTAL TO NAVION: RIGHT ILIAC 25X25X180, RIGHT ILIAC 8X59, INTO SMA 7X22). IT WAS REPORTED ON THE DAY OF THE INDEX PROCEDURE A CT OBSERVED AN UNKNOWN TYPE ENDOLEAK. PER THE PHYSICIAN THE CAUSE OF THE ENDOLEAK IS UNDETERMINED. IT WAS NOTED THE PATIENT EXPIRED ON (B)(6) 2020. THIS WAS CONFIRMED AS NON AORTIC RELATED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16223713 ↗InjuryNov 17, 2022Leak/Splash; Adverse Event Without Identified Device or Use Problem; Leak/Splash; Adverse Event Without Identified Device or Use Problem
A VALIANT NAVION STENT GRAFT WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A 81MM THORACIC ANEURYSM THAT HAD PRERUPTURED WITH A DISSECTION. THE PATIENT HAD 3 EXISTING VALIANT NAVION GRAFTS IMPLANTED 6 MONTHS PREVIOUSLY DURING AN UNKNOWN PROCEDURE. IT WAS REPORTED 2 DAYS POST THE PROCEDURE, CT IDENTIFIED A TYPE I ENDOLEAK INVOLVING THE DISTAL ASPECT OF THE ENDOGRAFT WITHIN THE S UPRARENAL ABDOMINAL AORTA. PER THE PHYSICIAN THE CAUSE OF THE ENDOLEAK IS UNDETERMINED. NO ADDITIONAL CLINICAL SEQUELAE WERE REPORTED AND THE PATIENT WILL BE MONITORED.
Patient problems: Insufficient Information; Vascular Dissection
MAUDE report 15814042 ↗InjuryMay 18, 2022Material Deformation; Material Deformation
VALIANT NAVION STENT GRAFTS WERE IMPLANTED TO REPAIR AN IVC ON (B)(6) 2019. THE NAVION STENTS WERE PLACED OFF LABEL IN THE INFERIOR VENA CAVA. IT WAS REPORTED THAT ON THE (B)(6) 2019, THE STENT GRAFTS WERE RELINED WITH A NON MDT STENT GRAFT DUE TO A COLLAPSED STENT. THE CAUSE OF THE STENT COLLAPSE WAS NOT PROVIDED. NO ADDITIONAL CLINICAL SEQUELAE WERE PROVIDED AND THE PATIENT IS FINE.
Patient problems: Insufficient Information
MAUDE report 14433135 ↗InjuryMar 11, 2022Leak/Splash; Adverse Event Without Identified Device or Use Problem; Leak/Splash; Adverse Event Without Identified Device or Use Problem
A VALIANT NAVION STENT GRAFT WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A THORACIC AORTIC ANEURYSM ON (B)(6) 2018. IT WAS REPORTED APPROXIMATELY 3 YEARS POST THE INDEX PROCEDURE FOLLOW UP CT IDENTIFIED AN IN STENT DISSECTION AND A TYPE II ENDOLEAK. THE PATIENT HAD NO KNOWN SYMPTOMS OR COMPLICATIONS. AN INTERVENTION WAS PERFORMED ON (B)(6) 2021 WHERE 3 NON MDT STENT GRAFTS WERE IMPLANTED TO RELINE. PER THE PHYSICIAN THE CAUSE OF THE DISSECTION WAS IS UNDETERMINED. NO ADDITIONAL CLINICAL SEQUELAE WERE REPORTED AND THE PATIENT IS FINE.
Patient problems: Vascular Dissection
MAUDE report 13734287 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.