Valiant Navion™ VNMC3434C52TU (UDI 00763000101008)Recalls & reported problems
Medtronic, Inc. · STENT GRAFT VNMC3434C52TU VAL NAV CS · Class 3 · Implant
All models of Valiant Navion (137)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000101008), received between Jun 26, 2020 and May 15, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Difficult or Delayed Positioning” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Recalls naming this device
- Feb 12, 2021Class IOpen, Classified
Due to the presence of type IIIb endoleaks, stent fractures, and stent ring enlargement.
Z-1201-2021 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Difficult or Delayed Positioning1
Patient problems
- Insufficient Information1
- Intimal Dissection1
- Pain1
- Unspecified Infection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMay 15, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A VALIANT NAVION STENT GRAFT (VNMC3434C52TU) WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A THORACIC AORTIC ANEURYSM. THE PATIENT HAD TWO EXISTING ANEURX AND A TALENT ABDOMINAL STENT GRAFTS IMPLANTED APPROXIMATELY 11 YEARS PRIOR, AND AN ADDITIONAL TALENT STENT GRAFT IMPLANTED APPROXIMATELY 10 YEARS PRIOR TO THE IMPLANTATION OF THE VALIANT NAVION. IT WAS REPORTED THAT SINCE THE IMPLANT OF THE VALIANT NAVION, THE PATIENT HAD PRESENTED TO ED WITH UTI AND POST POST-OP PAIN. IT WAS REPORTED CT IMAGING TAKEN 3YEARS AND 2 MONTHS AFTER THE VALIANT NAVION PROCEDURE, REVEALED POST-OPERATIVE CHANGES FROM TEVAR AND AORTOILIAC STENT GRAFT PLACEMENT. THE MAXIMUM THORACIC AORTIC DIAMETER MEASURED 59MM, UNCHANGED FROM PREVIOUS MEASUREMENTS, WITH NO OBSERVED ENDOLEAKS. THE MAXIMUM JUXTA-RENAL AORTIC ANEURYSM DIAMETER WAS APPROXIMATELY 53MM, CONSISTENT WITH PRIOR MEASUREMENTS. INTERVENTION OCCURRED 12 DAYS LATER , INVOLVING TEVAR, RELINING OF RENAL ARTERY STENTS, AND SPLENIC ARTERY EMBOLIZATION. IT WAS NOTED ON AN UNKNOWN DATE, INTERVAL INCREASE IN SIZE OF THE JUXTA RENAL AORTIC ANEURYSM MEASURING 55MM ALONG WITH POSTSURGICAL CHANGES OF THE OPEN DESCENDING THORACOABDOMINAL AORTIC ANEURYSM REPA
Patient problems: Insufficient Information; Pain; Unspecified Infection
MAUDE report 19319651 ↗InjuryJun 26, 2020Difficult or Delayed Positioning; Difficult or Delayed Positioning
A VALIANT NAVION STENT GRAFT WAS PLANNED FOR IMPLANTATION IN THE PATIENT FOR THE TREATMENT OF A PAU OF THE ASCENDING AORTA. IT WAS REPORTED THAT DURING THE INDEX PROCEDURE AN ATTEMPT TO INSERT THE DEVICE VIA THE LEFT SIDE WAS MADE BUT IT COULD NOT BE ADVANCED. THE PHYSICIAN ACCESSED THE RIGHT CAROTID AND CLOSED THE LEFT FEMORAL AND THE CASE WAS COMPLETED. AT THE END OF THE PROCEDURE IT WAS OBSERVED THAT THERE WAS A DISSECTION OF THE LEFT FEMORAL AND A REPAIR WITH A CUT-DOWN AND A PATCH WAS PERFORMED. AS PER THE PHYSICIAN THE CAUSE OF THE EVENT WAS ANATOMY RELATED DUE TO SMALL FEMORAL AND ILIAC VESSELS. NO ADDITIONAL CLINICAL SEQUELAE WERE REPORTED AND THE PATIENT IS FINE.
Patient problems: Intimal Dissection
MAUDE report 10199648 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page