Skip to content

CD HORIZON® Fenestrated Screw Set 55850027540Recalls & reported problems

Medtronic Sofamor Danek, Inc. · FNS MAS 55850027540 CCM 7.5 X 40 · Class 2 · Implant

All models of CD HORIZON Fenestrated Screw Set (27)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000146504), received between Jan 27, 2026 and Jan 27, 2026 — classified as 2 injuries.

The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 2 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device Dislodged or Dislocated2
  • Leak/Splash2
  • Loosening of Implant Not Related to Bone-Ingrowth2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 27, 2026Leak/Splash; Device Dislodged or Dislocated; Loosening of Implant Not Related to Bone-Ingrowth

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY. IT WAS REPORTED THAT FOLLOWING A MINIMALLY INVASIVE TRANSFORAMINAL LUMBAR INTERBODY FUSION (MIS TLIF) AT L5-S1 USING FOUR VOYAGER FNS SCREWS AUGMENTED WITH BONE CEMENT AND AN INTERBODY CAGE, INTRAOPERATIVE ASSESSMENT AND IMMEDIATE POSTOPERATIVE X-RAYS CONFIRMED SATISFACTORY PLACEMENT AND CONSTRUCT STABILITY. DURING A ROUTINE FOLLOW-UP APPOINTMENT, A SUBSEQUENT X-RAY REVEALED LOOSENING AND BACKING OUT OF A SET SCREW. REVISION SURGERY WAS PERFORMED, DURING WHICH REMOVAL OF THE EXISTING INSTRUMENTATION REVEALED BONE CEMENT LEAKAGE UNDERNEATH THE TULIP HEAD OF THE AFFECTED SCREW. THE FUSION CONSTRUCT WAS EXTENDED FROM L4 TO S1, AND NEW INSTRUMENTATION INCLUDING A BALLAST SCREW WAS PLACED. THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. ADDITIONAL INFORMATION RECEIVED FROM THE MANUFACTURER REPRESENTATIVE THAT THE PRIMARY REPORTED EVENT INVOLVED THE LOOSENING AND BACKING OUT OF ONE (1) SPECIFIC SCREW, WHICH WAS DIRECTLY ASSOCIATED WITH THE OBSERVED CEMENT LEAKAGE UNDER ITS TULIP HEAD. UPON VISUAL INSPECTION DURI

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24186513 ↗
  • InjuryJan 27, 2026Leak/Splash; Device Dislodged or Dislocated; Loosening of Implant Not Related to Bone-Ingrowth

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY. IT WAS REPORTED THAT FOLLOWING A MINIMALLY INVASIVE TRANSFORAMINAL LUMBAR INTERBODY FUSION (MIS TLIF) AT L5-S1 USING FOUR VOYAGER FNS SCREWS AUGMENTED WITH BONE CEMENT AND AN INTERBODY CAGE, INTRAOPERATIVE ASSESSMENT AND IMMEDIATE POSTOPERATIVE X-RAYS CONFIRMED SATISFACTORY PLACEMENT AND CONSTRUCT STABILITY. DURING A ROUTINE FOLLOW-UP APPOINTMENT, A SUBSEQUENT X-RAY REVEALED LOOSENING AND BACKING OUT OF A SET SCREW. REVISION SURGERY WAS PERFORMED, DURING WHICH REMOVAL OF THE EXISTING INSTRUMENTATION REVEALED BONE CEMENT LEAKAGE UNDERNEATH THE TULIP HEAD OF THE AFFECTED SCREW. THE FUSION CONSTRUCT WAS EXTENDED FROM L4 TO S1, AND NEW INSTRUMENTATION INCLUDING A BALLAST SCREW WAS PLACED. THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. ADDITIONAL INFORMATION RECEIVED FROM THE MANUFACTURER REPRESENTATIVE THAT THE PRIMARY REPORTED EVENT INVOLVED THE LOOSENING AND BACKING OUT OF ONE (1) SPECIFIC SCREW, WHICH WAS DIRECTLY ASSOCIATED WITH THE OBSERVED CEMENT LEAKAGE UNDER ITS TULIP HEAD. UPON VISUAL INSPECTION DURI

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24186511 ↗

Other Orthosis, spinal pedicle fixation devices

All Orthosis, spinal pedicle fixation devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page