NA C315S402Recalls & reported problems
Medtronic, Inc. · CATH C315S402 · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00763000160210), received between May 15, 2025 and Feb 11, 2026 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Accessory Incompatible” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Accessory Incompatible3
- Material Integrity Problem1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 11, 2026Use of Device Problem
IT WAS REPORTED THAT DURING IMPLANT THE PACING LEAD ENCOUNTERED PLACEMENT DIFFICULTY AND EXHIBITED HIGH THRESHOLDS. IT WAS NOTED THE SHEATH ENCOUNTERED PLACEMENT DIFFICULTY ALSO. THE PACING LEAD AND SHEATH WERE ATTEMPTED NOT USED, AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24316224 ↗MalfunctionDec 23, 2025Material Integrity Problem; Material Integrity Problem
IT WAS REPORTED THAT DURING THE IMPLANT PROCEDURE AFTER THE HIS LEAD WAS PLACED IN THE VENTRICLE, THE CATHETER WAS TORN, AND THE THRESHOLD INCREASED. A NEW CATHETER WAS USED TO REIMPLANT THE LEAD AND WHEN THE CATHETER WAS TORN, THE SLITTER BLADE ENCOUNTERED SIGNIFICANT RESISTANCE, THE BLADE COULD NOT SMOOTHLY CUT THE CATHETER, AND THE CATHETER WAS SCRAPPED. IT WAS ALSO NOTED THAT AFTER THE BLADE TORE THROUGH THE CATHETER SEVERAL TIMES, IT BECAME DEFORMED, AND CUTTING THROUGH THE CATHETER AGAIN FELT JERKY. THE HIS LEAD WAS THEN REMOVED AND TISSUE WAS FOUND ATTACHED TO THE TIP AND THE HELIX WAS DEFORMED. A NEW LEAD WAS IMPLANTED AND A NEW CUTTING BLADE WAS OPENED AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23878607 ↗MalfunctionSep 3, 2025Accessory Incompatible; Accessory Incompatible
IT WAS FURTHER REPORTED THAT THE RA LEAD REMAINS IN USE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22952349 ↗MalfunctionSep 3, 2025Accessory Incompatible; Accessory Incompatible
IT WAS REPORTED DURING IMPLANT OF THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM, THE RIGHT ATRIAL (RA) LEAD DISLODGED DURING SLITTING. THE LEAD WAS IMPLANTED AND REMAINS IN USE AND THE CATHETER AND SLITTER WERE ATTEMPTED/ NOT USED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22951115 ↗MalfunctionMay 15, 2025Accessory Incompatible; Accessory Incompatible
IT WAS FURTHER REPORTED THAT MULTIPLE CATHETERS WERE USED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22025735 ↗
Other Catheter, percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page