Attain Command™ + SureValve™ 6250VSRecalls & reported problems
Medtronic, Inc. · CATHETER 6250VS ATTAIN COMMAND · Class 2
All models of Attain Command + SureValve (17)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000160364), received between Aug 11, 2022 and Aug 11, 2022 — classified as 1 death.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Cardiac Tamponade1
- Low Blood Pressure/ Hypotension1
- Perforation1
- Pericardial Effusion1
- Vascular Dissection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathAug 11, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING THE IMPLANT OF THE LEFT VENTRICULAR (LV) LEAD AND USE OF THE CATHETER, IT WAS OBSERVED THAT THE GUIDEWIRE AND THE LEAD WERE ADVANCING DOWN A NON-VISUALIZED PATH ON THE VENOGRAM. A CORONARY SINUS DISSECTION HAD OCCURRED, THE PATIENT'S BLOOD PRESSURE WAS LOW, AND A CODE WAS CALLED. THE LEAD, THE CATHETER, THE SHEATH AND THE GUIDEWIRE WERE REMOVED IMMEDIATELY. PERICARDIAL EFFUSION AND TAMPONADE FROM THE PERFORATION WERE OBSERVED. PULSELESS ELECTRICAL ACTIVITY (PEA) WAS DIAGNOSED AND RESCUE ATTEMPTS WERE PERFORMED. THE PHYSICIAN PERFORMED A STERNOTOMY TO EVACUATE THE CAVITY AND REPAIR HEART. BLOOD AND FLUID WAS SUCCESSFULLY REMOVED TO RELIEVE TAMPONADE AND THE TEAR WAS SURGICALLY REPAIRED. THE PATIENT WAS GIVEN FOUR UNITS OF BLOOD. THE PATIENT WAS UNABLE TO BE RESUSCITATED AND PASSED AWAY.
Patient problems: Cardiac Tamponade; Low Blood Pressure/ Hypotension; Perforation; Pericardial Effusion; Vascular Dissection
MAUDE report 15212274 ↗
Other Catheter, percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page