Anteralign Spinal System with Titan nanoLock Surface technology 46812212Recalls & reported problems

Medtronic Sofamor Danek, Inc. · TRIAL 46812212 12DG 20W 12X60MM · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000193768), received between Jun 13, 2025 and Jun 13, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Use of Device Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Use of Device Problem1

Patient problems

  • Hemorrhage/Blood Loss/Bleeding1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 13, 2025Use of Device Problem; Use of Device Problem

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING L2/3/4/5/ OLIF L5/S TLIF L2/S2AI PPS FIXED THERAPY FOR LUMBAR SPINAL STENOSIS, KYPHOSIS. IT WAS REPORTED THAT DURING THE L4/5 OLIF PROCEDURE, THE TRIAL SIZES WERE INCREASED FROM 6°8MM TO 12°10MM TO 12°12MM. WHEN INSERTING THE 12°12MM TRIAL, IT DID NOT ENTER THE INTERVERTEBRAL SPACE AND SLIPPED FORWARD, INSERTING TO THE OPPOSITE SIDE. THE TRIAL WAS QUICKLY WITHDRAWN, BUT THERE WAS BLEEDING. GAUZE WAS PACKED TO STOP THE BLEEDING, AND ONCE THE BLEEDING WAS SOMEWHAT CONTROLLED, A 12°11.50MM IMPLANT WAS INSERTED. SURGIFLO (A HEMOSTATIC AGENT) WAS THEN USED, FOLLOWED BY COMPRESSION WITH GAUZE TO STOP THE BLEEDING. AFTER THE BLEEDING STOPPED, A DRAIN WAS PLACED AND THE INCISION WAS CLOSED.. THERE WAS A DELAY OF LESS THAN 60 MINUTES IN OVERALL PROCEDURE TIME. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: Hemorrhage/Blood Loss/Bleeding

    MAUDE report 22200630 ↗

Other Intervertebral fusion device with bone graft, lumbar devices