Adaptix™ Interbody System with Titan nanoLOCK™ Surface Technology 84332414Recalls & reported problems
Medtronic Sofamor Danek, Inc. · SPACER 84332414 ADAPTIX 24MM X 14MM · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000202934), received between Sep 8, 2021 and Sep 13, 2021 — classified as 2 injuries.
The most frequently reported specific device problem is “Migration” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Migration2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjurySep 13, 2021Migration; Migration
THE INFORMATION WAS REPORTED BY HEALTH CARE PROVIDER VIA A MANUFACTURING REPRESENTATIVE REGRADING A PATIENT WITH DEGENERATIVE DISK DISEASE FOR L4-S1 MAST TLIF SPINAL THERAPY. IT WAS REPORTED THAT DURING POST OP VISIT TO THE CLINIC, ADDITIONAL SCANS WERE TAKEN AND DISCOVERED THE CAGE MIGRATED POSTERIOR. CAGE IS MIGRATING BEFORE THE FUSION WAS COMPLETE. ADDITIONAL SURGERY WAS REQUIRED FOR REMOVAL OF THE CAGE. THERE WAS NO FURTHER INFORMATION REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12458221 ↗InjurySep 8, 2021Migration; Migration
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING TLIF AT L5-S1 FOR SPINAL THERAPY WITH DEGENERATIVE DISC DISEASE. IT WAS REPORTED THAT ABOUT A MONTH POST OP, THE CAGE HAS MIGRATED POSTERIORLY COMPARED TO TIME OF SURGERY. NO ISSUES PRESENT AT THE TIME OF SURGERY. SURGEON PLAN ON BRINGING IN THE PATIENT TO REMOVE THE CAGE. SURGERY DATE IS UNKNOWN AT THE MOMENT. PATIENT EXPRESSED DISCOMFORT DURING POST-OP CHECKUP. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. INFORMATION STATES THAT ON (B)(6) THE PATIENT CAME BACK IN TO HAVE HIS L5-S1 CAGE REMOVED. DURING THE REVISION CASE, 8 OF THE 10 SCREWS THAT WERE PREVIOUSLY PLACED HAD TO BE REMOVED AND UPSIZED DUE TO THEM BEING LOOSE. THE ONLY SCREWS THAT DIDN'T GET UPSIZED WAS AT THE L4 LEVEL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12437441 ↗
Other Intervertebral fusion device with bone graft, lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page