Valiant Navion™ VNMF4343C103TU (UDI 00763000260545)Recalls & reported problems
Medtronic, Inc. · STENT GRAFT VNMF4343C103TU VAL NAV FF · Class 3 · Implant
All models of Valiant Navion (137)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000260545), received between Nov 11, 2022 and Nov 11, 2022 — classified as 1 death.
The most frequently reported specific device problem is “Leak/Splash” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Leak/Splash1
Patient problems
- Insufficient Information1
- Pleural Effusion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathNov 11, 2022Leak/Splash; Leak/Splash
A VALIANT NAVION (V08147847) STENT GRAFT WAS IMPLANTED IN THE ENDOVASCULAR TREATMENT OF A TYPE IA ENDOLEAK AS A ENDOGRAFT EXTENSION WITH BILATERAL RENAL ARTERY AND SMA SNORKELING. A ENDURANT II STENT GRAFT SYSTEM HAD BEEN IMPLANTED 3 YEARS AND 5 MONTHS PREVIOUSLY. ABOUT 5 MONTHS POST THE NAVION IMPLANT, THE PATIENT WAS STRUGGLING WITH VARIOUS ENDOLEAKS AND COIL EMBOLIZATION AND GLUE WAS USED AS TREATMENT. 4 MONTHS LATER, AN AORTIC ENDOLEAK REQUIRED INTERVENTION WITH ONYX GLUE. ANOTHER 8 MONTHS LATER, THE PATIENT HAS A TAAA THAT IS AT AN OPERABLE SIZE. THE PATIENT UNDERWENT AN OPEN REPAIR, A NON MDT BRANCH GRAFT WAS PLACED WHILE THE VALIANT NAVION V08147847 WAS EXPLANTED. ANOTHER 6 MONTHS LATER, A NEW THORACIC AORTIC ANEURYSM AND THORACOABDOMINAL AORTIC DISSECTION WERE OBSERVED SO 6 VALIANT NAVIONS WERE IMPLANTED. A CT SCAN WAS PERFORMED JUST OVER 3 MONTHS POST THE 6 VALIANT NAVION IMPLANTS. A CT OF THE CHEST DEMONSTRATES THE DIMENSIONS OF THE THORACIC AORTIC ANEURYSM IN THE APPEARANCE OF THE ENDOGRAFT REPAIR ARE STABLE. THE NATIVE ANEURYSM MEASURES UP TO 6.3 CM AXIALLY IN THE DESCENDING AORTA. THE DENSITY OF THE CLOT IN THE ANEURYSM OF THE DESCENDING THORACIC AORTA IS DIMINISHED FR
Patient problems: Insufficient Information; Pleural Effusion
MAUDE report 15779964 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page