PipelineTM Flex Embolization Device with Shield TechnologyTM PED2-300-16Recalls & reported problems

Micro Therapeutics, Inc. · STENT PED2-300-16 V06 E-IFU · Class 3 · Implant

All models of PipelineTM Flex Embolization Device with Shield TechnologyTM (79)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000283988), received between Mar 17, 2023 and Mar 4, 2026 — classified as 2 injuries.

12 other recalls cover devices cleared under the same FDA submission (P100018); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Dysphasia1
  • Intracranial Hemorrhage1
  • Muscle Weakness/Atrophy1
  • Nervous System Injury1
  • Obstruction/Occlusion1
  • Paresis1
  • Shaking/Tremors1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 4, 2026Adverse Event Without Identified Device or Use Problem

    MEDTRONIC RECEIVED INFORMATION REGARDING A PATIENT WHO HAD THREE PIPELINE VANTAGE STENTS IMPLANTED TO TREAT A 2.8MM UNRUPTURED SACCULAR BASILAR ARTERY ANEURYSM 5 DAYS PRIOR. NO DEVICE MALFUNCTION WAS REPORTED ASSOCIATED WITH THIS EVENT. PATIENT'S VESSEL TORTUOSITY WAS NORMAL. DUAL ANTIPLATELET TREATMENT (DAPT) WAS ADMINISTERED. IT WAS REPORTED THAT AROUND 2000, THE PATIENT PRESENTED WITH DYSARTHRIA AND WEAKNESS IN ALL 4 EXTREMITIES. BY THE TIME NEUROLOGY HAD ASSESSED, THE PATIENT'S SYMPTOMS HAD ALMOST RESOLVED EXCEPT FOR SLIGHT DYSARTHRIA AND HAND PARESTHESIA. THE NEXT MORNING AT 0700, THE NEUROLOGICAL EXAM WAS NORMAL. HOWEVER, AROUND 0900, THE PATIENT AGAIN EXPERIENCED RIGHT UPPER EXTREMITY (RUE) WEAKNESS WITH ANARTHRIA AS WELL AS TREMORS IN LEFT UPPER EXTREMITY (LUE) AND JAW. BY 0930, THE PATIENT ALSO HAD MODERATE DYSARTHRIA WITHOUT APHASIA - COMPREHENSION AND NAMING WERE NORMAL. TREMORS DID NOT APPEAR CLONIC IN NATURE AND STOPPED WHEN HOLDING PATIENT'S HAND; SEIZURE SEEMED UNLIKELY. REPEAT COMPUTED TOMOGRAPHY (CT) WAS PERFORMED WITH NO OBSERVATION OF STROKE OR HEMORRHAGE. BASED ON THE AVAILABLE INFORMATION THE CARE TEAM CONSIDERED THE PATIENT'S FLUCTUATING NEUROLOGICAL SYMPTOMS

    Patient problems: Dysphasia; Muscle Weakness/Atrophy; Nervous System Injury; Obstruction/Occlusion; Paresis; Shaking/Tremors

    MAUDE report 24514137 ↗
  • InjuryMar 17, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    MEDTRONIC RECEIVED A REPORT THAT THE PATIENT HAD A PREVIOUSLY RUPTURED ANTERIOR COMMUNICATING ARTERY ANEURYSM THAT WAS COILED AND HAD A NECK REMNANT THAT HAD GROWN AND REQUIRED TREATMENT, AS WELL AS A POSTERIOR WALL COMPONENT THAT WAS UNPROTECTED BY PRIOR COILS. TH PHYSICIAN DECIDED THAT FLOW DIVERSION WAS MOST ADEQUATE TREATMENT FOR THIS CASE. HIS PLAN WAS TO PLACE THE PIPELINE DISTALLY IN IPSILATERAL (RIGHT) A2 INTO RIGHT A1. ACCESSING THE A2 WAS DIFFICULT, REQUIRING MULTIPLE ATTEMPTS WITH MULTIPLE TYPES OF WIRES. ONCE THE A2 WAS ACCESSED WITH THE WIRE, PHENOM27 WAS ADVANCED PAST THE TARGET TO BEGIN PIPELINE PLACEMENT. MEASUREMENTS WERE OBTAINED AND PED2-300-16 WAS CHOSEN BY THE PHYSICIAN TO BE OPTIMAL SIZE. THE DEVICE WAS LOADED INTO THE PHENOM27 AND DEPLOYED NORMALLY. FOLLOW UP IMAGING DISPLAYED ADEQUATE PLACEMENT AND PATENCY OF THE DEVICE. DURING RECOVERY OVERNIGHT THE PATIENT EXPERIENCED AN INTRACRANIAL HEMORRHAGE. THE PIPELINE WAS USED FOR AN INDICATION THAT IS APPROVED (ON-LABEL). THE REPORTED DEVICE AND ANY ACCESSORY DEVICES WERE PREPARED AS INDICATED IN THE INSTRUCTIONS FOR USE (IFU). THE PATIENT WAS UNDERGOING SURGERY FOR TREATMENT OF A SACCULAR, UNRUPTURED ANTERIOR COMM

    Patient problems: Intracranial Hemorrhage

    MAUDE report 16565552 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P100018. One submission often covers many models, so check the product and lot details in each record.

  • Z-1245-2025 · Jan 30, 2025 · Open, Classified
    Medtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-027-350-12, PED3-027-350-14, PED3-027-350-16, PED3-027-350-20, PED3-027-350-25, PED3-027-400-12, PE
  • Z-1246-2025 · Jan 30, 2025 · Open, Classified
    Medtronic Pipeline Vantage Embolization Device with Shield Technology, REF: PED3-021-350-16, PED3-021-250-14, PED3-021-350-20, PED3-021-250-20, PED3-021-300-16, PED3-021-300-20, PE
  • Z-2402-2021 · Jul 13, 2021 · Open, Classified
    Pipeline Flex Embolization Device
  • Z-2403-2021 · Jul 13, 2021 · Open, Classified
    EV3 Pipeline Flex Embolization Device with Flex Shield Technology
  • Z-1527-2020 · Feb 14, 2020 · Terminated
    ev3 Pipeline Flex Embolization Device. For neurological endovascular use.
  • Z-0308-2017 · Oct 5, 2016 · Terminated
    Alligator Retrieval Device The device is intended for use in the peripheral and neurovasculature for foreign body removal. Catalog No. FA-88810-20V04 FA-88810-20V06 FA-88810-30V04
  • Z-0307-2017 · Oct 5, 2016 · Terminated
    Pipeline Embolization Device (Pipeline Classic) The device is indicated for the endovascular treatment of adults (22 year of age or older) with large or giant widenecked intracrani
  • Z-0309-2017 · Oct 5, 2016 · Terminated
    Marathon Flow Directed Micro Catheter, UltraFlow HPC Flow Directed Micro Catheter Marathon Flow: The device is intended to access periphera and neurovasculature for the controlled
  • Z-0310-2017 · Oct 5, 2016 · Terminated
    X-Celerator Hydrophilic Exchange Guidewire Catalog No. 103-0601-300 103-0601-350V10 103-0602-350V06 103-0601-300V01 103-0602-300 103-0602-350V09 103-0601-300V02 103-0602-300V01 10
  • Z-0120-2016 · Sep 4, 2015 · Terminated
    -Pipeline Embolization Device -Pipeline Flex Embolization Device The Pipeline and Pipeline Flex Embolization Devices consist of a permanent implant combined with a guidewire based
  • Z-1453-2014 · Apr 1, 2014 · Terminated
    Pipeline Embolization Device (PED). Used endovascular treatment of adults with intracranial aneurysms in the internal carotid artery.
  • Z-2045-2013 · Jul 19, 2013 · Terminated
    Pipeline Embolization Device (PED) The Pipeline Embolization Device is indicated for the endovascular treatment of adults (22 years of age and older) with large or giant wide-neck

Other Intracranial aneurysm flow diverter devices

All Intracranial aneurysm flow diverter devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page