CD Horizon™ Astute™ Spinal System 1608451030Recalls & reported problems
Medtronic Sofamor Danek, Inc. · PEEK ROD 1608451030 6.0 X 6.9MM STR 30MM · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00763000312923), received between Apr 25, 2025 and Feb 26, 2026 — classified as 4 injuries.
The most frequently reported specific device problem is “Break” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break4
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Insufficient Information1
- Spinal Column Injury1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryFeb 26, 2026Break
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A DEVICE USED IN A POSTERIOR LUM BAR INTERBODY FUSION (PLIF) PROCEDURE AT LEVELS L4-S1. IT WAS REPORTED THAT BOTH PEEK RODS WERE FOUND TO BE FRACTURED IN THE PATIENT; THIS WAS NOT DIAGNOSED RADIOGRAPHICALLY AND WAS ONLY DISCOVERED DURING SURGICAL EXPOSURE. THE ROD BREAKAGE LIKELY CONTRIBUTED TO A DJACENT SEGMENT DEGENERATION, NECESSITATING A PLIF EXTENSION. THERE WERE NO PATIENT SYMPTOMS REPORTED, AND NO FURTHER COMPLICATIONS WERE NOTED REGARDING THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24450975 ↗InjuryFeb 9, 2026Break
INFORMATION WAS RECEIVED FROM THE HEALTH CARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A DEVICE USED FOR POSTERIOR LUMBAR INTERBODY FUSION PROCEDURE. LEVELS IMPLANTED: L4-5 IT WAS REPORTED THAT DURING ORIGINAL FUSION RODS WERE FOUND TO BE BROKEN. THE BROKEN RODS WERE EXPLANTED. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24288863 ↗InjuryFeb 9, 2026Break
INFORMATION WAS RECEIVED FROM THE HEALTH CARE PROFESSIONAL VIA A MANUFACTURER REPRESENTATIVE REGARDING A DEVICE USED FOR POSTERIOR LUMBAR INTERBODY FUSION PROCEDURE. LEVELS IMPLANTED: L4-5 IT WAS REPORTED THAT DURING ORIGINAL FUSION RODS WERE FOUND TO BE BROKEN. THE BROKEN RODS WERE EXPLANTED. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24288849 ↗InjuryApr 25, 2025Break; Break
INFORMATION WAS RECEIVED FROM AN UNKNOWN SOURCE REGARDING A PATIENT HAVING PLIF EXTENSION L3/4 FOR ADJACENT SEGMENT DEGENERATION AT L3/4. IT WAS REPORTED THAT DURING A PLIF EXTENSION PROCEDURE IMPLANT EXPERIENCED BREAKAGE. IT WAS CONFIRMED THAT NO FRAGMENT OF THE IMPLANT REMAINED IN THE PATIENT. NO PATIENT COMPLICATIONS OR SYMPTOMS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Insufficient Information; Spinal Column Injury
MAUDE report 21906691 ↗
Other Appliance, fixation, spinal intervertebral body devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- XLP 7565050Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430344Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- ATLANTIS® Anterior Cervical Plate System 876-170Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- XLP 7565060Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430113Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page