O-ARM® BI70002000 (UDI 00763000355609)Recalls & reported problems
Medtronic Navigation, Inc. · O-ARM SYS BI70002000 O2 UE 240V F EN EN · Class 2
All models of O-ARM (17)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00763000355609), received between Oct 25, 2021 and Jan 29, 2025 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Application Program Freezes or Fails to Launch” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Application Program Freezes or Fails to Launch2
- Radiation Output Failure2
- Device Sensing Problem1
- Mechanical Problem1
- Physical Resistance/Sticking1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 29, 2025Mechanical Problem; Radiation Output Failure; Mechanical Problem; Radiation Output Failure
MEDTRONIC RECEIVED INFORMATION REGARDING AN IMAGING SYSTEM BEING USED OUTSIDE OF A PROCEDURE. IT WAS REPORTED THAT IT WAS NOT POSSIBLE TO PERFORM A 3D IMAGE THERE WAS HANDSWITCH ISSUES. DURING A SYSTEM CHECK IT WAS NOT POSSIBLE TO PERFORM 3D IMAGES HOWEVER 2D IMAGES WERE POSSIBLE. BY PROVIDING PHONE SUPPORT IT WAS FOUND THAT THE MIDDLE BUTTON OF THE HANDSWITCHWAS NOT FUNCTIONING AND THEREFORE NEEDED TO BE REPLACED. THE SYSTEM WAS FULLY FUNCTIONAL WITH THE FOOTSWITCH. THE PROBABLE CAUSE OF THE REPORTED ISSUE WAS THE HANDSWITCH. THE NEXT STEP WAS TO REPLACE THE HANDSWITCH. THERE WAS NO PATIENT INVOLVEMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21269002 ↗MalfunctionNov 29, 2024Radiation Output Failure; Radiation Output Failure
MEDTRONIC RECEIVED INFORMATION REGARDING AN IMAGING SYSTEM BEING USED OUTSIDE OF A PROCEDURE. IT WAS REPORTED THAT COULD NOT SHOOT X-RAY FROM HAND SWITCH. THERE WAS NO PATIENT PRESENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20808943 ↗MalfunctionSep 22, 2022Physical Resistance/Sticking; Application Program Freezes or Fails to Launch; Physical Resistance/Sticking; Application Program Freezes or Fails to Launch
MEDTRONIC RECEIVED INFORMATION REGARDING AN IMAGING SYSTEM BEING USED OUTSIDE OF A PROCEDURE. IT WAS REPORTED THAT DURING A SYSTEM CHECK, THE SYSTEM WAS UNABLE TO TAKE 3D IMAGES BUT 2D WAS FINE. THE IMAGE ACQUISITION SYSTEM (IAS) WAS REBOOTED AND THE HAND-SWITCH WAS TESTED AND IT COULD NOT TAKE A 3D IMAGE. THE FOOT SWITCH WAS TESTED AND IT WAS WORKING FINE. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15462357 ↗MalfunctionAug 22, 2022Application Program Freezes or Fails to Launch; Application Program Freezes or Fails to Launch
MEDTRONIC RECEIVED INFORMATION REGARDING AN IMAGING SYSTEM BEING USED OUTSIDE OF A PROCEDURE. IT WAS REPORTED THAT THE IMAGE ACQUISITION SYSTEM (IAS) WAS NOT BOOTING UP, AS THE TOP BAR WAS SCROLLING AND A RED "X" WAS DISPLAYED ON THE NEXT TWO BARS. TROUBLESHOOTING STEPS WERE PERFORMED, WHICH SHOWED THAT THERE WAS AN ISSUE WITH THE UMBILICAL CABLE. THE SITE TRIED TO CONNECT TO THE REMOTE DESKTOP BUT IT WAS NOT POSSIBLE. IT WAS NOTED THAT THE PROBABLE CAUSE WAS SUSPECTED TO BE DUE TO THE COMPUTER OR POWER ENCLOSURE, AND THE UMBILICAL CABLE WAS TO BE REPLACED. NO PATIENT WAS PRESENT WHEN THE ISSUE WAS IDENTIFIED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15266443 ↗MalfunctionOct 25, 2021Device Sensing Problem; Device Sensing Problem
CONFLICTING INFORMATION WAS RECEIVED. IT WAS REPORTED, THAT NO PATIENT WAS PRESENT, AND THAT THERE WAS NO IMPACT TO THE PATIENT. IT WAS UNCLEAR WHETHER, OR NOT A PATIENT WAS PRESENT".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12691611 ↗
Other Image-intensified fluoroscopic x-ray system, mobile devices
- O-ARM® BI70002000Medtronic Navigation, Inc. · Image-intensified fluoroscopic x-ray system, mobile2 recalls2,132 reports
- O-ARM® BI70000028120Medtronic Navigation, Inc. · Image-intensified fluoroscopic x-ray system, mobile1,343 reports
- O-ARM® BI70002000Medtronic Navigation, Inc. · Image-intensified fluoroscopic x-ray system, mobile2 recalls1 death811 reports
- O-ARM® BI70002000Medtronic Navigation, Inc. · Image-intensified fluoroscopic x-ray system, mobile259 reports
- Zenition Zenition 70Philips Medical Systems Nederland B.V. · Image-Intensified Fluoroscopic X-Ray System, Mobile2 recalls80 reports
- O-armTM O2 Imaging System BI70002000Medtronic Navigation, Inc. · Image-intensified fluoroscopic x-ray system, mobile2 recalls1 death72 reports
- Zenition Zenition 50Philips Medical Systems Nederland B.V. · Image-Intensified Fluoroscopic X-Ray System, Mobile3 recalls21 reports
- O-ARM® BI70002000Medtronic Navigation, Inc. · Image-intensified fluoroscopic x-ray system, mobile2 recalls65 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page