NA C320LBBL45 (UDI 00763000747459)Recalls & reported problems

Medtronic, Inc. · CATHETER C320LBBL45 LARGE CURVE 45 GBL · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00763000747459), received between May 13, 2026 and Jun 2, 2026 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Material Integrity Problem” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 5 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520265
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Integrity Problem4
  • Break2
  • Accessory Incompatible1
  • Detachment of Device or Device Component1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 2, 2026Material Integrity Problem

    IT WAS REPORTED THAT DURING IMPLANT WHILST THE PHYSICIAN WAS SLITTING , THE CATHETER BROKE OFF AFTER THEY GOT PAST THE HUB. THE PHYSICIAN WAS ABLE TO GRAB THE CATHETER WITH AN INSTRUMENT AND HOOK THE CATHETER BACK INTO THE SLITTER AND SLIT THE REST OF THE WAY. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25359692 ↗
  • MalfunctionMay 21, 2026Accessory Incompatible

    IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD DISLODGED DURING IMPLANT. IT WAS FURTHER NOTED THAT THE RV LEAD WAS PLACED IN THE LEFT BUNDLE AREA, DURING SLITTING, THE SEALING RING OF THE CATHETER WAS NOT CUT AND REMAINED AROUND THE LEAD BODY. THE LEAD AND CATHETER WAS ATTEMPTED NOT USED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25239618 ↗
  • MalfunctionMay 20, 2026Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING IMPLANT THAT WHEN THEY BEGAN SLITTING THE CATHETER SHAFT WHEN THEY NOTICED THAT THE ENTIRE CATHETER HANDLE (PROXIMAL END) WAS SEVERED FROM THE CATHETER BODY. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25230342 ↗
  • MalfunctionMay 20, 2026Material Integrity Problem

    IT WAS REPORTED DURING IMPLANT THAT AFTER SUCCESSFUL PLACEMENT OF THE LEAD IN THE LEFT BUNDLE AREA, DURING SLITTING, THE SEALING RING OF THE CATHETER WAS NOT CUT AND REMAINED AROUND THE LEAD BODY WHICH RESULTED TO THE LEAD DISLODGEMENT. THE CATHETER WAS ATTEMPTED BUT NOT USED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25230270 ↗
  • MalfunctionMay 18, 2026Break; Material Integrity Problem

    IT WAS REPORTED DURING IMPLANT THAT THE CATHETER BROKE INTO TWO SEPARATE PIECES UPON SLITTING RESULTING IN HALF OF THE CATHETER BEING LEFT IN THE INTRODUCER REQUIRING SEPARATE PIECES NEEDING TO BE SLIT. THE CATHETER WAS ATTEMPTED BUT NOT USED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25198228 ↗
  • MalfunctionMay 13, 2026Break; Material Integrity Problem

    IT WAS REPORTED THAT DURING IMPLANT THE CATHETER BROKE IN HALF DURING SLIT. THE CATHETER WAS ATTEMPTED AND NOT USED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25159834 ↗

Other Catheter, percutaneous devices

All Catheter, percutaneous devices →