Skip to content

EverCross™ AB35W06060080Recalls & reported problems

Medtronic, Inc. · PTA AB35W06060080 EVERCROSS 035 V10 · Class 2

All models of EverCross (17)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000766511), received between Apr 30, 2025 and Apr 30, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Burst Container or Vessel” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Burst Container or Vessel1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 30, 2025Burst Container or Vessel; Burst Container or Vessel

    AN EVERCROSS PTA BALLOON WAS BEING USED FOR TREATMENT OF A CALCIFIED LESION IN THE PROXIMAL REGION OF THE RIGHT SUPERFICIAL FEMORAL ARTERY. A 7FR NON-MEDTRONIC SHEATH AND A 014 NITREX WIRE WERE USED. A NON-MEDTRONIC INFLATION DEVICE WAS USED WITH 50/50 CONTRAST INFLATION FLUID. IT WAS REPORTED DURING THE FIRST INFLATION A CIRCUMFERENTIAL/RADIAL BALLOON BURST OCCURRED. IT IS NOT KNOWN AT WHAT PRESSURE THE BALLOON BURST. THE DEVICE WAS SAFELY REMOVED, THE BALLOON DID NOT DETACH, AND THE PROCEDURE WAS COMPLETED USING ANOTHER EVERCROSS BALLOON. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21933622 ↗

Other Catheter, percutaneous devices

All Catheter, percutaneous devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page