EverCross™ AB35W08060080 (UDI 00763000766955)Recalls & reported problems
Medtronic, Inc. · PTA AB35W08060080 EVERCROSS 035 V10 · Class 2
All models of EverCross (17)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000766955), received between May 7, 2025 and May 7, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 7, 2025Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY PROCEDURE USING THE EVERCROSS 035, THE BALLOON DETACHED WITHIN THE SHEATH. THE DEVICE WAS BEING USED TO TREAT THE VENOUS OUTFLOW OF AN ARTERIOVENOUS FISTULA IN THE LEFT MID VEIN, WHERE A FIBROUS LESION WITH MINIMAL TORTUOSITY AND CALCIFICATION WAS PRESENT. THE LESION HAD A STENOSIS OF 90% AND MEASURED 60 MILLIMETERS IN LENGTH, WITH THE VEIN DIAMETER BEING 8 MILLIMETERS. A 6FR NON MEDTRONIC SHEATH AND A 035 GUIDEWIRE WERE USED. THE VESSEL WAS PRE AND POST DILATED USING EVERCROSS DEVICES. THE DEVICE PASSED THROUGH A PREVIOUSLY DEPLOYED EVERFLEX STENT. NO RESISTANCE ENCOUNTERED. A NON MEDTRONIC INFLATION DEVICE WAS USED WITH 50/50 CONTRAST. THE DETACHED COMPONENT WAS SAFELY REMOVED WITHIN THE SHEATH, AND THE PROCEDURE WAS COMPLETED USING A NEW DEVICE. NO INJURY/INTERVENTION ASSOCIATED WITH THIS EVENT. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21976579 ↗
Other Catheter, percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page