T2 STRATOSPHERE™ Expandable Corpectomy System 436013D (UDI 00763000856274)Recalls & reported problems

Medtronic Sofamor Danek, Inc. · CENTERPIECE 436013D 13MM D-SIZE · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00763000856274), received between May 12, 2025 and Aug 4, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Mechanical Problem” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Mechanical Problem3
  • Material Deformation1
  • Mechanical Jam1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 4, 2025Mechanical Problem; Mechanical Problem

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER REGARDING A PATIENT HAVING C6 CORPECTOMY. IT WAS REPORTED THAT SURGEON TRIED TO FINAL TIGHTEN AND THE SET SCREW WOULD NOT TORQUE OUT, DESPITE TRYING TWO DIFFERENT HANDLES. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22703085 ↗
  • MalfunctionJun 3, 2025Mechanical Problem; Material Deformation; Mechanical Jam; Mechanical Problem; Material Deformation; Mechanical Jam

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING POSTERIOR T12 CORPECTOMY. IT WAS REPORTED THAT THE DEVICE STUCK IN MID EXPANSION, WAS NOT EXPANDING AND COLLAPSING AS IT SHOULD AND STRIPPING WHILE ATTEMPTS WERE MADE TO EXPAND AND COLLAPSE THE CAGE. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22129561 ↗
  • MalfunctionMay 12, 2025Mechanical Problem; Mechanical Problem

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY. IT WAS REPORTED THAT DURING A SPINAL PROCEDURE INVOLVING THE TECHNICAL TEAM ENCOUNTERED SEVERAL ISSUES. INITIALLY, AFTER BREAKING OFF THE VERIFY TAB AND LOADING THE DEVICE ONTO THE INSERTER, THE DEVICE COULD NOT BE COLLAPSED. MULTIPLE ATTEMPTS WERE MADE TO RECONNECT THE INSERTER, AND EVENTUALLY, THE LOCK SCREWDRIVER WAS USED TO LOOSEN THE LOCKING MECHANISM, ALLOWING THE DEVICE TO COLLAPSE AND EXPAND. DURING THE EXPANSION, A CRUNCHING SOUND WAS HEARD, AND UPON ATTEMPTING FINAL TIGHTENING, A GRINDING SOUND WAS NOTED. THE DEVICE FAILED TO MAINTAIN ITS EXPANSION AND WAS SUBSEQUENTLY REMOVED. THERE WERE NO PATIENT COMPLICATIONS OR SYMPTOMS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. ADDITIONAL INFORMATION WAS RECEIVED VIA MANUFACTURER REPRESENTATIVE THAT PATIENT HAD A PRIOR EMERGENCY SURGERY AT ANOTHER FACILITY DUE TO LOSING MOTOR AND SENSORY FUNCTIONS. AN EMERGENCY LAMINECTOMY WAS DONE TO ALLEVIATE THE PRESSURE ON THE SPINAL CORD AND TRY TO RESTORE FUNCTIONS. THE PATIENT EVENTUALLY NOW CAME WITH A KYPHOSIS OF THE CERVICAL SPINE AND INFECTION. A TWO LEVE

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22000466 ↗

Other Spinal vertebral body replacement device devices

All Spinal vertebral body replacement device devices →