Launcher™ LA6AL20Recalls & reported problems

Medtronic, Inc. · CATHETER LA6AL20 LA 6F 100CM AL20 · Class 2

All models of Launcher (64)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000897987), received between Feb 13, 2026 and Feb 13, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Deformation Due to Compressive Stress” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Deformation Due to Compressive Stress1
  • Difficult to Insert1
  • Difficult to Remove1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 13, 2026Difficult to Insert; Difficult to Remove; Deformation Due to Compressive Stress; Material Deformation

    IT WAS REPORTED THAT DURING A PROCEDURE INVOLVING ONE 6F LAUNCHER GUIDE CATHETER, A KINK OCCURRED WHILE IN THE PATIENT APPROXIMATELY 12 INCHES FROM THE HUB AND REMOVAL DIFFICULTIES WERE ENCOUNTERED. THE LESION BEING TREATED WAS MODERATELY TORTUOUS, MILDLY CALCIFIED WITH 90% STENOSIS IN THE MID RIGHT CORONARY ARTERY (RCA). THE DEVICE WAS INSPECTED PRIOR TO USE WITH NO ISSUES NOTED. THE DEVICE WAS PREPPED PER IFU WITH NO ISSUES NOTED. RESISTANCE WAS NOT ENCOUNTERED WHEN ADVANCING THE DEVICE AND EXCESSIVE FORCE WAS NOT USED DURING INSERTION/DELIVERY. NO EXCESSIVE FORCE WAS USED AND THE DEVICE WAS NOT EXCESSIVELY TORQUED. IT WAS NOTED TO BE DIFFICULT TO PASS THE WIRE THROUGH THE LAUNCHER GUIDE CATHETER AND A KINK WAS NOTED ON THE X-RAY. IT WAS REPORTED TO BE DIFFICULT TO REMOVE THE LAUNCHER GUIDE CATHETER FOR APPROXIMATELY 5 MINUTES. IT WAS EVENTUALLY POSSIBLE TO ADVANCE THE SHEATH OVER THE KINK TO REMOVE THE CATHETER FROM THE BODY. THERE WAS NO HARM TO THE PATIENT AND IT WAS POSSIBLE TO RESUME THE CASE WITH ANOTHER LAUNCHER GUIDE CATHETER OF THE SAME MODEL. THERE WERE NO PATIENT COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24332256 ↗

Other Catheter, percutaneous devices

All Catheter, percutaneous devices →