HemoStar Long-Term Hemodialysis Catheter 5835190Recalls & reported problems
Bard Access Systems, Inc. · HEMOSTAR HEMODIALYSIS CATH, ALPHACURVE, AIRGUARD, 14.5 FR. 24cm · Class 2 · Implant
All models of HemoStar Long-Term Hemodialysis Catheter (13)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 15
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 00801741013492), received between Mar 13, 2018 and Oct 18, 2024 — classified as 3 injuries, 12 malfunctions.
The most frequently reported specific device problem is “Fracture” (8 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture8
- Fluid/Blood Leak5
- Detachment of Device or Device Component2
- Break1
- Defective Component1
- Deformation Due to Compressive Stress1
- Material Deformation1
- Material Frayed1
Patient problems
- No Consequences Or Impact To Patient6
- No Clinical Signs, Symptoms or Conditions5
- Injury3
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 18, 2024Fracture; Fracture
IT WAS REPORTED THAT DURING A DIALYSIS CATHETER PLACEMENT PROCEDURE, THE PROTECTIVE SLEEVE AROUND THE HUB WAS ALLEGEDLY SPLIT. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20478986 ↗MalfunctionOct 16, 2024Fracture; Deformation Due to Compressive Stress; Fracture; Deformation Due to Compressive Stress
IT WAS REPORTED THAT SOMETIME POST A DIALYSIS CATHETER PLACEMENT, IT WAS FOUND THAT THE CRACK HAD ALLEGEDLY APPEARED ON THE LUMEN OF LINE. IT WAS FURTHER REPORTED THAT THE WHITE PROTECTIVE SLEEVE IN THE HUB WAS ALLEGEDLY TORN. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20467827 ↗MalfunctionOct 16, 2024Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT SOMETIMES POST A DIALYSIS CATHETER PLACEMENT, THE RED HUB ON LUMEN ALLEGEDLY MOVED AND SPINS ROUND. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20461306 ↗MalfunctionOct 16, 2024Fracture; Detachment of Device or Device Component; Fracture; Detachment of Device or Device Component
IT WAS REPORTED THAT SOMETIMES POST A DIALYSIS CATHETER PLACEMENT, IT WAS NOTICED THAT CRACKS ALLEGEDLY APPEARED ON THE LUMENS ON A NUMBER OF LINES THAT HAVE BEEN INSERTED TO PATIENTS. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20460950 ↗MalfunctionJan 20, 2022Material Opacification; Material Protrusion/Extrusion; Material Opacification; Material Protrusion/Extrusion
IT WAS REPORTED THAT APPROXIMATELY ONE YEAR POST DIALYSIS CATHETER PLACEMENT, THE DEVICE ALLEGEDLY HAD WHITE OPACIFICATION OF THE TRANSPARENT PART. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13306789 ↗MalfunctionJul 21, 2020Fluid/Blood Leak; Fracture; Fluid/Blood Leak; Fracture
IT WAS REPORTED APPROXIMATELY TWO MONTHS POST PORT IMPLANT, THE DEVICE ALLEGEDLY LEAKED AROUND THE CUFF. IT WAS FURTHER REPORTED THAT, THERE WAS NO ISSUES IN PLACING THE CATHETER. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10300664 ↗MalfunctionJul 20, 2020Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT APPROXIMATELY 2 MONTHS POST CUFF PLACEMENT, THE DEVICE ALLEGEDLY HAD A LEAK AROUND THE CUFF. REPORTEDLY, THE CUFF WAS REPAIRED. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10294239 ↗MalfunctionJul 20, 2020Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT SOMETIME POST CATHETER IMPLANT, THE HEMOSTAR CATHETER WAS ALLEGEDLY FOUND TO LEAK AROUND THE CUFF. HOWEVER, NO ISSUES WERE FOUND WHEN PLACING THE CATHETER. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10294238 ↗MalfunctionJul 20, 2020Fluid/Blood Leak; Fracture; Fluid/Blood Leak; Fracture
IT WAS REPORTED THAT SOMETIME POST CATHETER IMPLANT, THE HEMOSTAR CATHETER WAS ALLEGEDLY FOUND TO LEAK AROUND THE CUFF. HOWEVER, NO ISSUES WERE FOUND WHEN PLACING THE CATHETER. THE PROCEDURE WAS COMPLETED BY REPLACING IT WITH A NEW CATHETER. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10294077 ↗InjuryApr 27, 2020Fracture; Fracture
IT WAS REPORTED THAT APPROXIMATELY 668 DAYS POST PORT PLACEMENT AN ALLEGED FISSURING (SPLIT OR CRACK) WAS IDENTIFIED IN CLOSE PROXIMITY OF THE TRIANGULAR CONNECTION IN THE PRE-CURVED CATHETER. IT WAS FURTHER REPORTED THAT PATIENT HOSPITALIZATION FOR URGENT REPLACEMENT WAS REQUIRED. PATIENT STATUS WAS NOT PROVIDED.
Patient problems: Injury
MAUDE report 10003012 ↗InjuryApr 27, 2020Fracture; Fracture
IT WAS REPORTED THAT APPROXIMATELY 73 DAYS POST PORT PLACEMENT AN ALLEGED FISSURING (SPLIT OR CRACK) WAS IDENTIFIED IN CLOSE PROXIMITY OF THE TRIANGULAR CONNECTION IN THE PRE-CURVED CATHETER. IT WAS FURTHER REPORTED THAT PATIENT HOSPITALIZATION FOR URGENT REPLACEMENT WAS REQUIRED. PATIENT STATUS WAS NOT PROVIDED.
Patient problems: Injury
MAUDE report 10003005 ↗InjuryApr 27, 2020Fracture; Fracture
IT WAS REPORTED THAT APPROXIMATELY 360 DAYS POST PORT PLACEMENT AN ALLEGED FISSURING (SPLIT OR CRACK) WAS IDENTIFIED IN CLOSE PROXIMITY OF THE TRIANGULAR CONNECTION IN THE PRE-CURVED CATHETER. IT WAS FURTHER REPORTED THAT PATIENT HOSPITALIZATION FOR URGENT REPLACEMENT WAS REQUIRED. PATIENT STATUS WAS NOT PROVIDED.
Patient problems: Injury
MAUDE report 10002942 ↗MalfunctionOct 4, 2019Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT SOME TIME POST DIALYSIS CATHETER PLACEMENT, THE ARTERIAL LUMEN OF THE DIALYSIS CATHETER ALLEGEDLY ASPIRATED AIR. REPORTEDLY, THE DEVICE WAS REMOVED AND REPLACED. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9157741 ↗MalfunctionJun 18, 2018Defective Component; Defective Component
IT WAS REPORTED THAT THE CLAMP ON THE CATHETER WAS CRACKED/BROKEN. THE CATHETER WAS REPAIRED. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7611931 ↗MalfunctionMar 13, 2018Material Frayed; Material Deformation; Break; Material Frayed; Material Deformation
IT WAS REPORTED THAT THE WIRE WAS BROKEN NEAR THE CURVED END OF THE CATHETER. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7335697 ↗
Other Catheter, hemodialysis, implanted devices
- Palindrome 8888145014Mozarc Medical US LLC · Catheter, hemodialysis, implanted1 recall312 reports
- Palindrome 8888145015Mozarc Medical US LLC · Catheter, hemodialysis, implanted2 recalls1 death219 reports
- HemoStar Long-Term Hemodialysis Catheter 5833690Bard Access Systems, Inc. · Catheter, hemodialysis, implanted2 deaths290 reports
- Palindrome 8888119369PMozarc Medical US LLC · Catheter, hemodialysis, implanted3 recalls1 death14 reports
- HemoStar Long-Term Hemodialysis Catheter 5833730Bard Access Systems, Inc. · Catheter, hemodialysis, implanted1 death141 reports
- GlidePath Long-Term Hemodialysis Catheter with Preloaded Stylet 5393230Bard Access Systems, Inc. · Catheter, hemodialysis, implanted5 deaths138 reports
- Palindrome 8888123404PMozarc Medical US LLC · Catheter, hemodialysis, implanted2 recalls1 death17 reports
- Palindrome 8888119364PMozarc Medical US LLC · Catheter, hemodialysis, implanted2 recalls1 death17 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page