EQUISTREAM Long-Term Hemodialysis Catheter 5905280Recalls & reported problems

Bard Access Systems, Inc. · EQUISTREAM HEMODIALYSIS CATH, ALPHACURVE, AIRGUARD, 14.5 FR. 28cm · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
1
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00801741013812), received between Mar 20, 2019 and Feb 14, 2025 — classified as 1 death, 4 malfunctions.

The most frequently reported specific device problem is “Defective Component” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Defective Component3
  • Fluid/Blood Leak1
  • Material Split, Cut or Torn1
  • Restricted Flow rate1

Patient problems

  • No Consequences Or Impact To Patient3
  • Exsanguination1
  • No Patient Involvement1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • DeathFeb 14, 2025Fluid/Blood Leak; Material Split, Cut or Torn; Fluid/Blood Leak; Material Split, Cut or Torn

    IT WAS REPORTED THAT WHILE THE PATIENT'S CAREGIVER WAS CHANGING THE DRESSING AROUND THE DIALYSIS CATHETER, THE TUBING WAS INADVERTENTLY CUT BENEATH ONE OF THE PORTS. IT WAS FURTHER REPORTED THAT THE PATIENT BEGAN BLEEDING OUT THROUGH THE CUT CATHETER END AND COLLAPSED. REPORTEDLY, THE CAREGIVER CALLED 911 AND THE PATIENT WAS TRANSPORTED TO THE EMERGENCY ROOM. THE BLEEDING COULD NOT BE STOPPED UNTIL THE TUBE WAS CLAMPED IN THE EMERGENCY ROOM. DESPITE ALL EFFORTS INCLUDING TRANSFUSION, THE PATIENT COULD NOT BE RESUSCITATED. THE PATIENT EXPIRED DUE TO EXSANGUINATION.

    Patient problems: Exsanguination

    MAUDE report 21382410 ↗
  • MalfunctionAug 12, 2019Restricted Flow rate; Restricted Flow rate

    IT WAS REPORTED THAT SOME TIME AFTER THE PLACEMENT OF THE DIALYSIS CATHETER, THE FLOW RATE WAS ALLEGEDLY DECREASED. REPORTEDLY, THE DIALYSIS MACHINE ALARM GOES OFF. IT WAS FURTHER REPORTED THAT THE HEALTH CARE PROVIDER WAS ABLE TO INFUSE AND ASPIRATE SUCCESSFULLY AFTER THE DECLOTTING PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8884041 ↗
  • MalfunctionJun 5, 2019Defective Component; Defective Component

    IT WAS REPORTED THAT UPON OPENING THE DIALYSIS CATHETER INSERTION KIT, THE PLASTIC TIP OF THE TUNNELER WAS ALLEGEDLY FOUND TO BE BROKEN. THERE WAS NO PATIENT CONTACT.

    Patient problems: No Patient Involvement

    MAUDE report 8670770 ↗
  • MalfunctionApr 26, 2019Defective Component; Defective Component

    IT WAS REPORTED THE TIP OF THE TUNNELER ALLEGEDLY BROKE. REPORTEDLY, A NEW DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8558598 ↗
  • MalfunctionMar 20, 2019Defective Component; Defective Component

    IT WAS REPORTED THE TIP OF THE TUNNELER ALLEGEDLY BROKE. REPORTEDLY, A NEW DEVICE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8436847 ↗

Other Catheter, hemodialysis, implanted devices