Bardex® Lubricath® Foley Catheter Coude Tip 0168L14Recalls & reported problems

C. R. Bard, Inc. · Bardex® Lubricath® Carson Model Foley Catheter Coude Tip 5cc Balloon Lubricious Coated · Class 2

All models of Bardex Lubricath Foley Catheter Coude Tip (11)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Bardex Lubricath Coude Tip Foley catheter is a soft, lubricated urinary catheter with a curved tip and a small balloon, used to drain the bladder. The 54 reports mostly describe the balloon or the tubing breaking, splitting or rupturing during use — sometimes leaking water, or coming out on its own — and a few mention bits of material left in the patient. Six reports involved injuries and none involved deaths. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
55
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 55 adverse event reports that list this exact device (DI 00801741017810), received between May 3, 2017 and Sep 28, 2026 — classified as 7 injuries, 48 malfunctions.

The most frequently reported specific device problem is “Break” (8 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 3 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 4 reportsMay 2025: 2 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break8
  • Material Fragmentation7
  • Burst Container or Vessel5
  • Material Rupture5
  • Material Split, Cut or Torn5
  • Fluid/Blood Leak4
  • Material Puncture/Hole4
  • Device Damaged Prior to Use3

Patient problems

  • No Clinical Signs, Symptoms or Conditions25
  • No Consequences Or Impact To Patient19
  • No Known Impact Or Consequence To Patient19
  • No Patient Involvement5
  • Foreign Body In Patient4
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available3
  • No Code Available2
  • No Information2

Recent adverse event reports

The 25 most recent of 55 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Difficult to Remove

    Patient problems: Insufficient Information

    MAUDE report 50917216 ↗
  • MalfunctionApr 1, 2026Difficult to Remove

    IT WAS REPORTED THAT AFTER USE THE FOLEY CATHETER WATER WOULDN'T DRAIN DUE TO THE CHIMAN STYLE DESIGN, SO THE SHAFT WAS CUT AND REMOVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24758371 ↗
  • MalfunctionMar 6, 2026Inflation Problem

    IT WAS REPORTED THAT DURING USE THE FOLEY CATHETER CAUSED DIFFICULTY IN INJECTING WATER. THE VALVE FOR INJECTING FIXED WATER WAS CRACKED, MAKING IT DIFFICULT TO INJECT WATER, SO IT WAS DISCONTINUED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24535979 ↗
  • MalfunctionJan 26, 2026Material Rupture

    IT WAS REPORTED THAT THERE WAS A RUPTURE IN THE FOLEY CATHETER DURING PLACEMENT AND IT WAS SPONTANEOUSLY EXPELLED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24185610 ↗
  • MalfunctionDec 31, 2025Material Puncture/Hole; Material Puncture/Hole

    IT WAS REPORTED THAT DURING USE WATER LEAKED FROM THE FOLEY CATHETER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23936850 ↗
  • MalfunctionDec 10, 2025Material Puncture/Hole; Material Puncture/Hole

    IT WAS REPORTED THAT NATURAL REMOVAL OCCURRED OF THE FOLEY CATHETER SEVERAL HOURS AFTER PLACEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23771989 ↗
  • MalfunctionJul 30, 2025Tear, Rip or Hole in Device Packaging; Tear, Rip or Hole in Device Packaging

    IT WAS REPORTED THAT BEFORE USE, STERILIZATION PACKAGE OF FOLEY CATHETER WAS TORN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22668540 ↗
  • MalfunctionJul 15, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT, FOLEY CATHETER BALLOON WAS FOUND TO BE BROKEN DURING PLACEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22509881 ↗
  • MalfunctionMay 16, 2025Difficult to Remove; Difficult to Remove

    IT WAS REPORTED THAT THE BALLOON DID NOT DEFLATE WHEN THE PATIENT CAME IN A COUPLE OF DAYS LATER TO GET IT REMOVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22036252 ↗
  • MalfunctionMay 9, 2025Flaked; Flaked

    IT WAS REPORTED THAT THE FOLEY CATHETERS WERE SHEDDING PARTICLES (PCN#0168L14 AND PCN#175814).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21994701 ↗
  • MalfunctionApr 28, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT THE FOLEY BALLOON HAD BURST. IT WAS UNCLEAR IF LOT NUMBER WAS REQUESTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21917879 ↗
  • MalfunctionApr 16, 2025Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material

    IT WAS REPORTED THAT THEY HAD ENCOUNTERED WITH THE TWO CATHETERS PURCHASED LUBRI-SIL¿ BARD 175814 LUBRICATH¿ BARDEX 0168L14. AFTER FLUSHING SOLUTION FROM THOSE FOLEY CATHETERS AND THEY OBSERVED LOTS OF PARTICULATE MATTER IN THE FLUSHED LIQUID. AS PER THE MAIL NOTIFICATION RECEIVED ON 07APR2025, THE FOLEYS WERE USED TRANSIENTLY, SOLUTIONS WERE FLUSHED VIA CATHETERS WITHIN 10MIN. THE DETAILS OF THE CATHETERS, LUBRI-SIL CAT# 175814, LOT# NGJT1507; BARDEX , CAT# 0168L14; LOT# NGJP2155. THE FOLEYS WERE USED TO TEST IN CLINICAL USE SIMULATION. IT WAS EXPECTED TO BE IN THE BODY FOR 30MIN. SIMPLY SALINE FLUSHING THROUGH CATHETERS CAUSING PARTICULATE MATTERS, REGARDLESS OF PATIENTS¿ CONDITIONS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21848901 ↗
  • InjuryApr 14, 2025Material Fragmentation; Material Fragmentation

    IT WAS REPORTED THAT DURING PLACEMENT THE FOLEY CATHETER FRACTURED AND THE TIP, END POINT WAS LEFT IN THE BODY DUE TO PATIENT'S SELF-EXTRACTION.

    Patient problems: Foreign Body In Patient

    MAUDE report 21832604 ↗
  • MalfunctionApr 4, 2025Material Rupture; Material Rupture

    IT WAS REPORTED THAT THE STERILE WATER LEAK FROM THE FOLEY CATHETER BALLOON AND WHEN CHECKED TO SEE THAT THE BALLOON WAS DEFLATED, IT WAS FOUND TO BE DAMAGED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21773103 ↗
  • InjuryMar 13, 2025Material Fragmentation; Material Fragmentation

    IT WAS REPORTED THAT AN 84-YEAR-OLD MALE ADMITTED TO HOSPITAL WITH ALTERED MENTAL STATUS. PATIENT HAD A HISTORY OF HYPERLIPIDAEMIA, CORONARY ARTERY DISEASE WITH STENTS, BENIGN PROSTATE HYPERTROPHY, AND DEMENTIA. PATIENT WAS DIAGNOSED WITH A URINARY TRACT INFECTION ALONG WITH INFLUENZA, DURING A PERIOD OF CONFUSION THE PATIENT PULLED THE URINARY CATHETER OUT. THE TIP OF THE CATHETER CONTAINING THE BALLOON SPLIT OFF. A COMPUTED TOMOGRAPHY (CT) OF THE PELVIS INDICATED THE BALLOON WAS RETAINED WITHIN THE PATIENT'S BLADDER. THE NEXT DAY, THE PATIENT WAS TAKEN TO THE OPERATING ROOM WHERE A CYSTOSCOPY WAS PERFORMED. THE TIP OF THE CATHETER WAS RETRIEVED WITHOUT ANY ISSUES. THE PATIENT WAS DISCHARGED TO A REHABILITATION FACILITY. ALL REMAINING STOCK OF THE CATHETER LOT WAS REMOVED FROM THE ORGANIZATION. THE ALLEGEDLY DEFECTIVE CATHETER WOULD BE RETURNED TO THE MANUFACTURER FOR EVALUATION.

    Patient problems: Foreign Body In Patient

    MAUDE report 21593425 ↗
  • MalfunctionDec 31, 2024Fracture; Fracture

    IT WAS REPORTED THAT THIS WAS AN INCIDENT WHERE THE FOLEY CATHETER CRACKED. IT WAS POSSIBLE THAT THE PATIENT MAY HAD TORN IT OFF, BUT IT WAS NOT BROKEN AND WAS NOT LEFT INSIDE THE BODY. PER FOLLOW UP INFORMATION RECEIVED VIA IBC ON 18DEC2024, THAT THE CRACK WAS ON THE INFLATION FUNNEL SIDE OF THE BIFURCATED PART.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21047638 ↗
  • MalfunctionDec 31, 2024Fracture; Material Split, Cut or Torn; Fracture; Material Split, Cut or Torn

    IT WAS REPORTED THAT FOLEY CATHETER CRACK INCIDENT. DUE TO LACK OF ACTUAL ITEMS, A TOTAL OF THREE CASES OCCURRED IN THE SAME WARD.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21047386 ↗
  • MalfunctionDec 31, 2024Fracture; Material Split, Cut or Torn; Fracture; Material Split, Cut or Torn

    IT WAS REPORTED THAT FOLEY CATHETER CRACKED EVENT. THERE WAS A POSSIBILITY THAT THE CATHETER WAS TORN OFF BY THE PATIENT, BUT THE INFORMATION WAS NOT AVAILABLE DUE TO THE DESTRUCTION OF THE ACTUAL CATHETER. A TOTAL OF THREE INCIDENTS OCCURRED IN THE SAME WARD.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21047196 ↗
  • MalfunctionJan 9, 2024Material Puncture/Hole; Material Puncture/Hole

    IT WAS REPORTED THAT ON (B)(6) 2023, AFTER THE FOLEY CATHETER IMPLANTATION, THE STERILE WATER WAS INJECTED AND WHEN THE CATHETER WAS CHECKED TO SEE IF IT COULD BE REMOVED, IT SLIPPED OUT. THE BALLOON WAS DEFLATED. STERILE WATER LEAKED FROM INSIDE THE LUMEN, NOT FROM OUTSIDE THE CATHETER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18474564 ↗
  • MalfunctionDec 4, 2023Inaccurate Flow Rate; Inaccurate Flow Rate

    IT WAS REPORTED THAT AFTER INSERTING THE FOLEY CATHETER INTO THE PATIENT, THEY COULD NOT CONFIRM THE OUTFLOW OF URINE. SO THEY REMOVED IT AND REINSERTED A NEW CATHETER, WHICH CONFIRMED THE OUTFLOW OF URINE. THERE WAS A POSSIBILITY THAT THERE WAS NO HOLE AT THE TIP OF THE CATHETER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18256851 ↗
  • MalfunctionAug 3, 2023Burst Container or Vessel; Burst Container or Vessel

    IT WAS REPORTED THAT THE FOLEY CATHETER BALLOON BURST ONCE INSIDE PATIENT. PROPER AMOUNT OF WATER WAS INSTILLED, SO THE USER WAS UNSURE WHY THE BALLOON BURST. PER ADDITIONAL INFORMATION VIA EMAIL FROM IBC ON (B)(6) 2023,IT WAS STATED THAT PATIENT STATUS WAS FINE. THE FOLEY CATHETER WAS INSERTED AND A FEW HOURS LATER THE PATIENT CALLED NURSING TO REPORT SINCE THEY FELT A POP AND THAT THEIR CATHETER WAS FALLING OUT. NURSE ASSESSED AND NOTED A SPLIT IN THE BALLOON PART OF THE CATHETER. 10CC WAS INSERTED INTO THE BALLOON AS PER INSTRUCTIONS ON THE CATHETER END. IT WAS STATED THAT THAT THERE WAS SOME SLIGHT TRAUMA TO THE URETHRA, BUT ALSO HAD TO HAVE ANOTHER CATHETER INSERTION SO NOT SURE WHICH CAME FIRST. IT WAS UNKNOWN WHAT MEDICAL INTERVENTION WAS PROVIDED. PER ADDITIONAL INFORMATION RECEIVED VIA EMAIL ON 27JUL2023, THE CUSTOMER WAS UNSURE IF THE URETHRA TRAUMA WAS THERE BEFORE THE FIRST CATHETER WAS INSERTED. THERE WAS NO ISSUE WITH THE SECOND CATHETER, IT WAS STATED TO ALERT THAT ANOTHER CATHETER WAS ABLE TO BE PLACED IN THE CUSTOMER DUE TO THE ORIGINAL CATHETER BURSTING. IT WAS REPORTED THAT THE PATIENT STATUS WAS FINE, AND NO ADDITIONAL MEDICAL INTERVENTION WAS REPORTED.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 17450303 ↗
  • InjuryMar 21, 2023Material Fragmentation; Material Fragmentation

    IT WAS REPORTED THAT THE CATHETER GOT BROKEN. ABOUT 25CM OF THE DISTAL PART OF THE CATHETER WAS RETRIEVED, BUT THE CATHETER TIP HAD REMAINED IN THE PATIENT BLADDER WHICH WAS RECOVERED LATER. PER ADDITIONAL INFORMATION RECEIVED VIA INVESTIGATORS NOTIFICATION ON 07MAR2023, STATED THAT THE CATHETER FRAGMENT LEFT BEHIND IN THE PATIENT'S BLADDER WAS SPONTANEOUSLY DISCHARGED FROM THE PATIENT BODY ON MARCH 2. THE SALES REPRESENTATIVE RECOVERED IT ON MARCH 7.THE PATIENT WAS MALE. THE PATIENT WAS HOSPITALIZED IN A PSYCHIATRIC WARD AND HE MAY HAVE SELF-EXTRACTED THE CATHETER. PER FOLLOW UP INFORMATION RECEIVED FROM IBC ON 08MAR2023, CATHETER BREAKAGE.

    Patient problems: Foreign Body In Patient

    MAUDE report 16583156 ↗
  • MalfunctionAug 17, 2022Fungus in Device Environment; Fungus in Device Environment

    IT WAS REPORTED THAT THE FOLEY CATHETER HAD MOLD OR YELLOWING ON THEM. 2 PACKS OF 18 TOTAL OF THE 28 WERE MOLDY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15243261 ↗
  • MalfunctionJun 10, 2022Material Fragmentation; Component Misassembled; Material Fragmentation; Component Misassembled

    IT WAS REPORTED THAT THE FOLEY CATHETER WAS REMOVED FROM THE PATIENT AND WAS STRAIGHT CATHETERIZED THE PREVIOUS DAY AND FOUND THAT THE CATHETER WAS MISSING ABOUT 3/4 INCH OF ITS TIP. STATED THAT UROLOGY DID NOT FIND IT IN THE PATIENT'S BLADDER AND FELT LIKE THAT MAY HAVE BEEN PRESENT FROM THE BEGINNING DUE TO A MANUFACTURING DEFAULT. ALSO STATED THAT THEY CHECKED THE SUPPLIES IN PACU AND PSU 3 AND THEY ALL APPEARED TO BE FULLY INTACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14655250 ↗
  • MalfunctionAug 25, 2021Failure to Infuse; Failure to Infuse

    IT WAS REPORTED THAT THE FOLEY CATHETER BALLOON DID NOT INFLATE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12366206 ↗

Other CATHETER, COUDE devices

All CATHETER, COUDE devices →