Bardex® Lubricath® Foley Catheter Creevy Model 01267520Recalls & reported problems
C. R. Bard, Inc. · Bardex® Lubricath® Creevy Model Foley Catheter 3 way Continuous Irrigation 75cc Balloon Lubricious Coated · Class 2
All models of Bardex Lubricath Foley Catheter Creevy Model (3)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This Bardex Lubricath Foley catheter is a three-way, continuous irrigation catheter used to drain the bladder. The 47 reports mostly describe it not working as expected — leaking fluid or blood, balloon deflation problems and bursting, holes or punctures in the material, difficulty removing it, and irrigation channels that come blocked or damaged. No deaths and no injuries were reported. There have been no recalls naming this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 47
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 47 adverse event reports that list this exact device (DI 00801741018800), received between Feb 12, 2018 and Mar 30, 2026 — classified as 47 malfunctions.
The most frequently reported specific device problem is “Decrease in Pressure” (8 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Decrease in Pressure8
- Difficult to Remove7
- Fluid/Blood Leak7
- Material Puncture/Hole7
- Deflation Problem6
- Burst Container or Vessel5
- Failure to Infuse3
- Component Misassembled2
Patient problems
- No Clinical Signs, Symptoms or Conditions39
- No Consequences Or Impact To Patient11
- No Known Impact Or Consequence To Patient6
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- No Information1
- No Patient Involvement1
Recent adverse event reports
The 25 most recent of 47 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 30, 2026Complete Blockage
IT WAS REPORTED THAT FOLEY CATHETER WAS DAMAGED AS PRESENT A MALFUNCTION IN THE THIRD IRRIGATION CHANNEL. THE CHANNEL APPEARS TO BE OBSTRUCTED.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; No Clinical Signs, Symptoms or Conditions
MAUDE report 24719353 ↗MalfunctionMar 3, 2026Material Puncture/Hole
IT WAS REPORTED THAT AFTER USE, THE FOLEY CATHETER FALLS OUT OF THE PATIENT BECAUSE OF LEAKING BALLOON.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24500458 ↗MalfunctionNov 7, 2025Material Puncture/Hole; Material Puncture/Hole
IT WAS REPORTED THAT, BALLON DEFORMATION OCCURRED OF THE FOLEY CATHETER BEFORE USE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23495278 ↗MalfunctionSep 26, 2025Material Puncture/Hole; Material Puncture/Hole
IT WAS REPORTED THAT DURING USE THE FOLEY CATHETER HAD LEAKAGE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23155125 ↗MalfunctionJun 26, 2025Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT THE FOLEY CATHETER HAD LEAKAGE DURING USE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22338275 ↗MalfunctionApr 25, 2025Component Misassembled; Component Misassembled
IT WAS REPORTED THAT MISSING ACCESSORIES. NO WATER STOP VALVE AT THE WATER INJECTION POINT OF THE FOLEY CATHETER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21909670 ↗MalfunctionApr 21, 2025Material Rupture; Material Rupture
IT WAS REPORTED THAT THE FOLEY CATHETER BALLOON RUPTURED AND LEAKED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21873628 ↗MalfunctionDec 30, 2024Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT DURING USE THE FOLEY CATHETER WAS LEAKED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21036934 ↗MalfunctionJun 18, 2024Inflation Problem; Failure to Infuse; Inflation Problem; Failure to Infuse
IT WAS REPORTED THAT THE FOLEY CATHETER BALLOON COULD NOT BE INFLATED OR DISCHARGED DURING A PRETEST.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19557144 ↗MalfunctionMay 16, 2024Inability to Irrigate; Inability to Irrigate
IT WAS REPORTED THAT BY USING THE FOLEY CATHETER, IRRIGATION CANNOT BE FILLED WITH WATER. THEY REPLACED A NEW ONE. PER FOLLOW UP INFORMATION RECEIVED VIA IBC ON (B)(6) 2024, STATED THAT THEY CANNOT PERFORM IRRIGATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19331209 ↗MalfunctionApr 8, 2024Difficult to Remove; Difficult to Remove
IT WAS REPORTED THAT WATER IN THE FOLEY CATHETER COULD NOT BE DRAINED. PER ADDITIONAL INFORMATION VIA EMAIL FROM IBC ON 01APR2024, THE WATER COULD NOT BE DRAINED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19060587 ↗MalfunctionJan 22, 2024Failure to Infuse; Failure to Infuse
IT WAS REPORTED THAT WATER CANNOT BE PENETRATED INTO THE BALLOON OF FOLEY CATHETER BEFORE USE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18553361 ↗MalfunctionJan 12, 2024Difficult to Remove; Difficult to Remove
IT WAS REPORTED THAT WHEN THE FOLEY CATHETER WAS REMOVED, IT COULD NOT BE DRAINED, SO IT WAS CUT OFF DIRECTLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18503569 ↗MalfunctionDec 14, 2023Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT FOLEY CATHETER HAD LEAKAGE FROM PIPE WALL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18329040 ↗MalfunctionAug 4, 2023Burst Container or Vessel; Burst Container or Vessel
IT WAS REPORTED THAT THE FOLEY CATHETER BALLOON RUPTURED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17466754 ↗MalfunctionJul 18, 2023Difficult to Remove; Difficult to Remove
IT WAS REPORTED THAT THE FOLEY CATHETER BALLOON COULD NOT DEFLATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17341921 ↗MalfunctionJun 28, 2023Material Puncture/Hole; Material Puncture/Hole
IT WAS REPORTED THAT THE BALLOON LEAKED AND THE FOLEY CATHETER FELL OUT OF THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17215768 ↗MalfunctionJun 13, 2023Failure to Infuse; Failure to Infuse
IT WAS REPORTED THAT AFTER INSERTING THE FOLEY CATHETER INTO THE URETHRA, THERE WAS NO RESISTANCE WHILE INJECTING THE STERILE WATER THROUGH THE INFLATION LUMEN BUT THEN A RESISTANCE WAS FELT WHILE INJECTING THE CLEANING SOLUTION, SO THE CATHETER WAS REMOVED AND THE CLEANING SOLUTION WAS INJECTED AGAIN INTO THE IRRIGATION LUMEN AND TESTED, RESULTING IN BALLOON INFLATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17118632 ↗MalfunctionMay 19, 2023Disconnection; Disconnection
IT WAS REPORTED THAT THE VALVE GOT DISCONNECTED AND FELL OUT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16962599 ↗MalfunctionMay 12, 2023Burst Container or Vessel; Burst Container or Vessel
IT WAS REPORTED THAT THE BALLOON HAD BURST AND DROPPED. PER FOLLOW-UP INFORMATION RECEIVED FROM IBC ON 03MAY2023, STATED THAT THE "BURST AND DROP" MEANT THAT "CATHETER FELL OUT AND THE BALLOON BURST".
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16918365 ↗MalfunctionApr 28, 2023Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material
IT WAS REPORTED THAT THE WATER INJECTED INTO THE BALLOON HAS HIGH RESISTANCE DUE TO A DUST FOUND. PER ADDITIONAL INFORMATION VIA EMAIL FROM IBC ON 14APR2023,WATER INJECTED INTO THE BALLOON HAS HIGH RESISTANCE ('DUST WAS FOUND' - THIS PART IS REDUNDANT).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16831035 ↗MalfunctionNov 2, 2022Inability to Irrigate; Inability to Irrigate
IT WAS REPORTED THAT THE WATER COULD NOT BE POURED INTO THE BLADDER TO FLUSH. IT WAS MENTIONED THAT THE USER CHANGED A NEW FOLEY CATHETER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15713814 ↗MalfunctionAug 15, 2022Fracture; Material Fragmentation; Fracture; Material Fragmentation
IT WAS REPORTED THAT THERE WAS A CRACK ON THE FOLEY CATHETER TIP UPON OPENING THE PACKAGE. THE DEVICE WAS NOT USED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15224139 ↗MalfunctionJul 18, 2022Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT UPON OPENING THE PACKAGE AND CHECKING THE FOLEY CATHETER, THE PLASTIC PART OF THE FUNNEL WAS PARTIALLY CHIPPED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15043455 ↗MalfunctionJun 24, 2022Decrease in Pressure; Decrease in Pressure
IT WAS REPORTED THAT WATER LEAKED FROM THE CONNECTION OF THE INFLATION VALVE DURING THE PRETEST. THERE WAS NO BALLOON RUPTURE OR TEAR WAS FOUND AND THE PATIENT DID NOT HAVE ANY URINE STONE. PER FOLLOW UP VIA IBC ON 09JUN2022, THE CAUSE OF THE LEAK WAS UNKNOWN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14801592 ↗
Other CATHETER, COUDE devices
- Bardex® Lubricath® Foley Catheter 0165L14C. R. Bard, Inc. · CATHETER, COUDE562 reports
- Bardex® Lubricath® Foley Catheter 0165L16C. R. Bard, Inc. · CATHETER, COUDE539 reports
- Bardia® Foley Catheter Silicone Coated 123516AC. R. Bard, Inc. · CATHETER, COUDE381 reports
- Bardia® Foley Catheter Silicone Coated 123514AC. R. Bard, Inc. · CATHETER, COUDE195 reports
- SureStep™ Foley Tray System Bardex® Lubricath® Foley Catheter A899916C. R. Bard, Inc. · CATHETER, COUDE3 recalls19 reports
- Bardia® Foley Catheter Silicone Coated 123518AC. R. Bard, Inc. · CATHETER, COUDE153 reports
- SureStep™ Foley Tray System Bardex® Lubricath® Foley Catheter A902916C. R. Bard, Inc. · CATHETER, COUDE2 recalls50 reports
- Bard® Lubricath® Foley Catheter 365716C. R. Bard, Inc. · CATHETER, COUDE117 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page