Bard® Large-Capacity Urinary Drainage Bag 253509ARecalls & reported problems
C. R. Bard, Inc. · Bard® Large-Capacity Urinary Drainage Bag · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00801741029578), received between Aug 8, 2018 and Dec 19, 2019 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Restricted Flow rate” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Restricted Flow rate2
- Backflow1
- Break1
- No Flow1
Patient problems
- Burning Sensation1
- No Known Impact Or Consequence To Patient1
- Pain1
- Urinary Tract Infection1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryDec 19, 2019Restricted Flow rate; Backflow; Break; Restricted Flow rate
IT WAS REPORTED THAT THE PATIENT STATED THE URINE WAS GOING BACK INTO THE TUBE. HE STATED THAT IT HAD CAUSED HIM AN INFECTION. HE ASKED FOR A BIGGER BAG OR ONE THAT HAD A FLOATING BALL TO STOP THE REFLUX. HE ALSO STATED THAT ONLY THE BAG HAD BROKEN AT THE SEAM. NO MEDICAL INTERVENTION REPORTED. IT WAS LATER REPORTED FROM THE CUSTOMER VIA PHONE ON 19DEC2019, HE EXPERIENCED A BURNING SENSATION ALONG WITH THE URINARY TRACT INFECTION. THE CUSTOMER NOTED THAT THE UTI WAS TREATED WITH PRESCRIBED ANTIBIOTICS.
Patient problems: Burning Sensation; Urinary Tract Infection
MAUDE report 9498511 ↗MalfunctionAug 8, 2018Restricted Flow rate; No Flow; Restricted Flow rate
IT WAS REPORTED THAT THE URINE WOULD NOT DRAIN INTO THE DRAINAGE BAG. ALLEGEDLY THE PATIENT EXPERIENCED A HURTING BLADDER. NO MEDICAL INTERVENTION WAS REPORTED.
Patient problems: No Known Impact Or Consequence To Patient; Pain
MAUDE report 7763818 ↗
Other COLLECTOR, URINE, (AND ACCESSORIES) FOR INDWELLING CATHETER devices
- Bardia® Closed System Urinary Drainage Bag With Anti-Reflux Chamber 802001C. R. Bard, Inc. · COLLECTOR, URINE, (AND ACCESSORIES) FOR INDWELLING CATHETER117 reports
- Bard® Urine Meter with Bag 153214AC. R. Bard, Inc. · COLLECTOR, URINE, (AND ACCESSORIES) FOR INDWELLING CATHETER107 reports
- Bard® Urinary Drainage Bag with Anti-Reflux Chamber 154002C. R. Bard, Inc. · COLLECTOR, URINE, (AND ACCESSORIES) FOR INDWELLING CATHETER107 reports
- Bard® Urine Meter with Bag 153204C. R. Bard, Inc. · COLLECTOR, URINE, (AND ACCESSORIES) FOR INDWELLING CATHETER106 reports
- SureStep™ Foley Tray System Complete Care® Add-A-Foley Catheter A399400AC. R. Bard, Inc. · COLLECTOR, URINE, (AND ACCESSORIES) FOR INDWELLING CATHETER2 recalls0 reports
- Bard® Urinary Drainage Bag 153509C. R. Bard, Inc. · COLLECTOR, URINE, (AND ACCESSORIES) FOR INDWELLING CATHETER91 reports
- Bard® Urinary Drainage Bag 153504C. R. Bard, Inc. · COLLECTOR, URINE, (AND ACCESSORIES) FOR INDWELLING CATHETER89 reports
- SureStep™ Foley Tray System Complete Care® Add-A-Foley Catheter A304400AC. R. Bard, Inc. · COLLECTOR, URINE, (AND ACCESSORIES) FOR INDWELLING CATHETER1 recall12 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page