Bardex® Urethral Catheter Robinson Model 056110Recalls & reported problems

C. R. Bard, Inc. · Bardex® Urethral Catheter Robinson Model · Class 2

All models of Bardex Urethral Catheter Robinson Model (8)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00801741033506), received between Jan 14, 2022 and Feb 20, 2025 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Flaked” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 2 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Flaked4
  • Device Contaminated During Manufacture or Shipping3
  • Naturally Worn2
  • Material Split, Cut or Torn1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 20, 2025Material Split, Cut or Torn; Material Split, Cut or Torn

    IT WAS REPORTED THAT THEIR CLINICAL STAFF STATED THAT THEY NOTICED CRACKING IN GENERAL PURPOSE LATEX INTERMITTENT CATHETERS [PCN #277710 (BATCH #UNK), (BATCH #NGFS3051, BATCH #NGHV0932, BATCH #NGGR2390, BATCH #NGGQ3730], [PCN #277708 (BATCH #NGHS3453, BATCH #NGGZ0495, BATCH #NGGT3524,BATCH #NGGY3130, BATCH #NGGS2682)], [PCN #94180 (BATCH #NGEY3152)], [PCN #94120, BATCH #NGEV4510)], [PCN #56110 (BATCH #NGFW2958)], [PCN #56114 (BATCH #NGGV2774)]. THEY WERE CONCERNED THAT THEY WERE BRITTLE AND COULD AFFECT PATIENT SAFETY. BASED OFF OF THEIR CONCERNS, THEY SWEPT THEIR SUPPLY AREAS AND FOUND THE CATHETERS BELOW TO SHOW THE SAME CHARACTERISTICS. THEY WOULD LIKE TO HAVE THOSE EVALUATED. THEY HAVE ALSO INCLUDED A PHOTO BELOW, WHICH SHOWS THE CRACKING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21423626 ↗
  • MalfunctionMay 22, 2024Naturally Worn; Naturally Worn

    IT WAS REPORTED THAT CUSTOMER HAD SEVERAL ROBINSON INTERMITTENT CATHETERS ON THEIR SHELF THAT WERE APPEARING TO LOSE COLOR OR BREAK DOWN OR HAD CRACKS AS IN THE ATTACHED PICTURE. THEY ALL SAID THAT THEY HAD 3 YEARS OR MORE YEARS OF SHELF-LIFE LEFT, BUT SURGEONS WERE LEERY TO USE THEM DUE TO THIS BREAK DOWN (LOT#NGJP0217 AND LOT#NGHT0223).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19372270 ↗
  • MalfunctionMay 22, 2024Naturally Worn; Naturally Worn

    IT WAS REPORTED THAT CUSTOMER HAD SEVERAL ROBINSON INTERMITTENT CATHETERS ON THEIR SHELF THAT WERE APPEARING TO LOSE COLOR OR BREAK DOWN OR HAD CRACKS AS IN THE ATTACHED PICTURE. THEY ALL SAID THEY HAD 3 YEARS OR MORE YEARS OF SHELF-LIFE LEFT, BUT SURGEONS WERE LEERY TO USE THEM DUE TO THIS BREAK DOWN (LOT#NGJP0217 AND LOT#NGHT0223). PER FOLLOW UP RESPONSE VIA EMAIL ON 22MAY2024, STATED THAT CUSTOMER WOULD NOT USE CATHETERS ON PATIENTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19371590 ↗
  • MalfunctionJan 19, 2022Flaked; Flaked

    IT WAS REPORTED THAT THE LOOSE PARTICULATES WAS COMING OFF FROM THE PACKAGING OF ROBINSON INTERMITTENT CATHETERS. PER ADDITIONAL INFORMATION RECEIVED VIA EMAIL ON 10JAN2022, IT WAS REPORTED THAT THE LOOSE PARTICULATES WERE FOUND BY THE MEDLINE PRODUCTION TEAM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13290586 ↗
  • MalfunctionJan 14, 2022Flaked; Device Contaminated During Manufacture or Shipping; Flaked; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT THE ROBINSON INTERMITTENT CATHETER PACKAGING WAS FLAKED OFF ONTO OTHER COMPONENTS INSIDE THE PACK. THE PROVIDED LOTS WERE (NGDZ3241), (NGEZ0776), (NGFN2700).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13259729 ↗
  • MalfunctionJan 14, 2022Flaked; Device Contaminated During Manufacture or Shipping; Flaked; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT THE ROBINSON INTERMITTENT CATHETER PACKAGING WAS FLAKED OFF ONTO OTHER COMPONENTS INSIDE THE PACK. THE PROVIDED LOTS WERE NGDZ3241, NGEZ077 AND NGFN2700.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13259270 ↗
  • MalfunctionJan 14, 2022Flaked; Device Contaminated During Manufacture or Shipping; Flaked; Device Contaminated During Manufacture or Shipping

    IT WAS REPORTED THAT THE ROBINSON INTERMITTENT CATHETER PACKAGING WAS FLAKED OFF ONTO OTHER COMPONENTS INSIDE THE PACK. THE PROVIDED LOTS WERE NGDZ3241, NGEZ077 AND NGFN2700.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13258949 ↗

Other CATHETER, UROLOGICAL devices

All CATHETER, UROLOGICAL devices →