Power-Trialysis catheter 5608240Recalls & reported problems

Bard Access Systems, Inc. · 13Fr Trialysis ST 24cm Tray · Class 2

All models of Power-Trialysis catheter (22)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00801741041914), received between Feb 2, 2018 and Apr 2, 2025 — classified as 8 malfunctions.

The most frequently reported specific device problem is “Material Deformation” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Deformation4
  • Material Frayed2
  • Contamination /Decontamination Problem1
  • Difficult to Remove1
  • Fluid/Blood Leak1
  • Kinked1

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • No Consequences Or Impact To Patient2
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 2, 2025Contamination /Decontamination Problem; Contamination /Decontamination Problem

    IT WAS REPORTED FOREIGN BODY CLEARLY VISIBLE BEFORE USE IN THE SEALED PACKAGING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21753399 ↗
  • MalfunctionNov 22, 2023Material Frayed; Material Deformation; Material Frayed; Material Deformation

    IT WAS REPORTED BY THE CUSTOMER "WHEN INSERTING THE CATHETER OVER THE GUIDE WIRE, IT KINKED SUBCUTANEOUSLY TOGETHER WITH THE CATHETER. THE CATHETER REMOVED, LEAVING THE GUIDE WIRE IN PLACE (STILL CORRECTLY POSITIONED INTRAVASCULARLY). SLIGHTLY STRONGER TRACTION THAN NORMAL WAS APPLIED. SPIRAL FROM WHICH THE GUIDE WIRE IS MADE HAS STRETCHED INTO A THIN WIRE (SPIRAL WAS TWISTED OPEN)". 11/09/2023 - ADDITIONAL INFORMATION PROVIDED BY BD REP AS FAR AS WE CAN CURRENTLY JUDGE, THERE WERE NO CONSEQUENTIAL DAMAGES. THE CATHETER IS IN USE. ONLY THE WIRE WAS DAMAGED, NOT THE CATHETER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18192963 ↗
  • MalfunctionSep 26, 2023Material Frayed; Material Frayed

    IT WAS REPORTED THE RESUSCITATOR ENCOUNTERED DIFFICULTIES DURING THE INSTALLATION OF THE DIALYSIS KT AND WHEN SHE WANTED TO REMOVE THE GUIDE, IT DETERIORATED. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17818898 ↗
  • MalfunctionAug 31, 2022Fluid/Blood Leak; Fluid/Blood Leak

    IT WAS REPORTED THE CATHETER IS FAULTY (DRUG LEAKAGE). NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15328040 ↗
  • MalfunctionDec 8, 2021Material Deformation; Material Deformation

    IT WAS REPORTED INSERTION OF SHALDON FEMORALLY, PUNCTURE WITHOUT ANY PROBLEM AND ADVANCEMENT OF THE WIRE WITH CONTROL OF THE WIRE INTRAVASALLY, DILATATION WITHOUT ANY PROBLEM, WIRE ALWAYS FREELY MOVABLE DURING THIS TIME. NOW AN ATTEMPT TO SELDING THE CATHETER OVER THE WIRE IT WAS NOT POSSIBLE, BECAUSE THE WIRE (PART THAT WAS IN THE MUSCLE) HAS MASSIVE BENDS. IT ALSO SHOWS THAT THE WIRE KINKS AT THE SLIGHTEST TOUCH. CONSEQUENCE: IN A FULLY ANTICOAGULATED PATIENT, 2ND PUNCTURE, SAME BRAND BUT NEW SET - NO PROBLEMS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12960877 ↗
  • MalfunctionMay 1, 2020Material Deformation; Material Deformation

    THE FOLLOWING WAS REPORTED: THE CUSTOMER HANDS OVER THE GUIDE WIRE OF A POWER TRIALYSIS CATHETER TO THE SALES REP. THIS WAS REMOVED AFTER THE CATHETER WAS SUCCESSFULLY PLACED IN THE FEMORAL ARTERY. THE GUIDE WIRE KINKED SEVERAL TIMES, AND THE WIRE PULLED APART. THE PATIENT WAS NOT HARMED. THE USERS ALSO REPORTED THAT THE ENCLOSED DILATOR SHOWS SMALL EDGES AT THE TIP. THIS HAS BEEN NOTICED SEVERAL TIMES. NO HARM TO THE PATIENT HERE EITHER. 4/27/2020-TWO SAMPLES WERE RETURNED. THIS REPORT ADDRESSES THE SECOND SAMPLE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10018313 ↗
  • MalfunctionFeb 20, 2020Material Deformation; Material Deformation

    THE FOLLOWING WAS REPORTED: THE CUSTOMER HANDS OVER THE GUIDE WIRE OF A POWER TRIALYSIS CATHETER TO THE SALES REP. THIS WAS REMOVED AFTER THE CATHETER WAS SUCCESSFULLY PLACED IN THE FEMORAL ARTERY. THE GUIDE WIRE KINKED SEVERAL TIMES, AND THE WIRE PULLED APART. THE PATIENT WAS NOT HARMED. THE USERS ALSO REPORTED THAT THE ENCLOSED DILATOR SHOWS SMALL EDGES AT THE TIP. THIS HAS BEEN NOTICED SEVERAL TIMES. NO HARM TO THE PATIENT HERE EITHER.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9732314 ↗
  • MalfunctionFeb 2, 2018Kinked; Difficult to Remove

    IT WAS REPORTED THAT THE GUIDEWIRE KINKED UPON INSERTION, WHICH LED TO THE PHYSICIAN NOT BEING ABLE TO INSERT THE POWER-TRIALYSIS CATHETER. THE PHYSICIAN REQUESTED A LESS MALLEABLE WIRE FROM THEIR CATH LAB TO THEN BE ABLE TO COMPLETE THE INSERTION PROCEDURE.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7239269 ↗

Other CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED devices

All CATHETER, HEMODIALYSIS, TRIPLE LUMEN, NON-IMPLANTED devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page