Closed Wound Suction 0034610Recalls & reported problems
C. R. Bard, Inc. · ReliaVac 400 Closed Wound Suction Kit, Medium 1/8" (10Fr., 3.2mm) O.D. PVC Drain, 12.5" Hole Pattern, X-Ray Opaque Stripe with Attached Trocar, 400cc Evacuator · Class 1 · Implant
All models of Closed Wound Suction (24)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
Quick summary
This is a Bard ReliaVac closed wound suction kit, a portable non-powered drain used after surgery to remove fluid from a wound. The 62 reports mostly describe the drain or its balloon failing to inflate or suction properly, plus cracks, ruptures, and pieces breaking off; a few mention a drain tip left behind and needing removal in the operating room. Reports describe 5 injuries and no deaths. There are no recalls for this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 62
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 62 adverse event reports that list this exact device (DI 00801741049125), received between Apr 13, 2017 and Apr 21, 2021 — classified as 5 injuries, 57 malfunctions.
The most frequently reported specific device problem is “Inflation Problem” (20 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Inflation Problem20
- Suction Problem12
- Break9
- Burst Container or Vessel9
- Material Rupture5
- Disconnection4
- Device Contamination with Chemical or Other Material3
- Connection Problem2
Patient problems
- No Known Impact Or Consequence To Patient46
- No Consequences Or Impact To Patient37
- No Patient Involvement7
- No Clinical Signs, Symptoms or Conditions5
- Foreign Body In Patient3
- No Information3
- No Code Available2
Recent adverse event reports
The 25 most recent of 62 reports, in the reporter's own words as published by the FDA.
InjuryApr 21, 2021Disconnection; Difficult to Remove; Disconnection; Difficult to Remove
IT WAS REPORTED THAT THERE WAS AN UNSUCCESSFUL DRAIN REMOVAL FROM KNEE. THE PATIENT HAD TO BE TAKEN BACK TO THE OPERATING ROOM FOR REMOVAL OF THE DRAIN TIP. IT WAS NOTED THAT THE DRAIN'S PLUG WAS INTACT AFTER REMOVAL.
Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions
MAUDE report 11702525 ↗MalfunctionApr 20, 2021Inflation Problem; Inflation Problem
IT WAS REPORTED THAT IT WAS DIFFICULT TO INFLATE THE BALLOON OF THE WOUND DRAIN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11694535 ↗MalfunctionJan 5, 2021Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material
IT WAS REPORTED THAT FOREIGN MATERIAL LIKE BLACK STAINS WERE FOUND ON THE INSIDE OF THE EVACUATOR WHEN THE PACKAGE WAS OPENED.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Patient Involvement
MAUDE report 11118609 ↗MalfunctionDec 6, 2020Suction Failure; Suction Failure
IT WAS REPORTED THAT THE EVACUATOR WAS DIFFICULT TO ASPIRATE ON THE DAY OF USE.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient
MAUDE report 10955795 ↗MalfunctionNov 2, 2020Deflation Problem; Inflation Problem; Deflation Problem; Inflation Problem
IT WAS REPORTED THAT THE EVACUATOR WAS UNABLE TO SUCTION COMPLETELY DUE TO THE BALLOON DEFLATION.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient
MAUDE report 10770321 ↗MalfunctionJul 30, 2020Difficult to Insert; Incorrect Measurement; Incorrect Measurement
IT WAS REPORTED THAT THE TROCAR ANGLE CHANGED WHEN DRAINING SPINE, WHICH MADE THE TROCAR DIFFICULT TO INSERT.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 10346094 ↗MalfunctionJul 30, 2020Difficult to Insert; Incorrect Measurement; Incorrect Measurement
IT WAS REPORTED THAT THE TROCAR ANGLE CHANGED WHEN DRAINING SPINE, WHICH MADE THE TROCAR DIFFICULT TO INSERT.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 10346037 ↗MalfunctionMay 21, 2020Inflation Problem
IT WAS REPORTED THAT IT WAS DIFFICULT TO INFLATE THE SUCTION EVACUATOR ON THE 3RD DAY OF USE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 10080759 ↗MalfunctionApr 28, 2020Inflation Problem
IT WAS REPORTED THAT IT WAS DIFFICULT TO INFLATE THE SUCTION EVACUATOR.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 10006416 ↗MalfunctionApr 2, 2020Device Contamination with Chemical or Other Material
IT WAS REPORTED THAT FIRST HEALTH OF THE CAROLINAS RECEIVED DRAIN BAGS THAT HAD A FLUID INSIDE. THE AMOUNT OF FLUID WAS LESS THAN HALF A CC (A FEW DROPS). THE FACILITY HAS USED THE DRAIN BAGS ON PATIENTS. NO MEDICAL INTERVENTION.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9915404 ↗MalfunctionMar 21, 2020Inflation Problem; Failure to Infuse; Failure to Infuse
IT WAS REPORTED THAT IT WAS DIFFICULT TO INFLATE AT THE TIME OF SUCTION.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9863584 ↗MalfunctionMar 11, 2020Inflation Problem; Pressure Problem; Appropriate Device Problem Term/Code Not Available; Inflation Problem
IT WAS REPORTED THAT THE RELIAVAC 400 WOULD NOT HOLD PRESSURE. ONCE THE INLET TUBE WAS REPLACED THE DEVICE WORKED AS DESIGNED.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9819113 ↗MalfunctionFeb 19, 2020Difficult to Remove; Pressure Problem; Difficult to Remove
IT WAS REPORTED THAT IT WAS UNABLE TO ASPIRATE, AS NEGATIVE PRESSURE WAS NOT APPLIED EFFECTIVELY ALTHOUGH THE BALLOON WAS INFLATED DURING A PRETEST.
Patient problems: No Patient Involvement
MAUDE report 9727615 ↗MalfunctionFeb 7, 2020Inflation Problem
IT WAS REPORTED THAT THE RELIAVAC BALLOON EVACUATOR WAS DIFFICULT TO INFLATE THE INTERNAL BALLOON, AND WOULD NOT HOLD VACUUM.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9683019 ↗MalfunctionJan 6, 2020Break; Crack; Fluid/Blood Leak; Break
IT WAS REPORTED THAT A CRACK IN THE Y CONNECTOR ON THE EVACUATOR WAS FOUND DUE TO A LEAK OF FLUID.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9554748 ↗MalfunctionDec 26, 2019Inflation Problem
IT WAS REPORTED THAT THE RELIAVAC WAS DIFFICULT TO INFLATE THE BALLOON ON THE DAY OF USE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9520836 ↗MalfunctionDec 19, 2019Inflation Problem
IT WAS REPORTED THAT IT WAS DIFFICULT TO INFLATE THE SUCTION DEVICE DURING USE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9497958 ↗MalfunctionNov 19, 2019Break
IT WAS REPORTED THAT THE DRAIN TUBE ON THE RELIAVAC EVACUATOR BROKE WHEN THE USER PULLED IT WITH MOSQUITO FORCEPS WHILE REMOVING THE DEVICE FROM THE PATIENT. THIS OCCURRED ON THE 2ND DAY OF USE. IT WAS LATER REPORTED FROM THE INTERNATIONAL BUSINESS CENTER (IBC) VIA EMAIL (B)(6) 2019 THAT THE BREAK IN THE TUBE OCCURRED NEAR THE DRAIN HOLES ON THE END OF THE TUBE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9342288 ↗MalfunctionNov 19, 2019Inflation Problem
IT WAS REPORTED THAT THE BALLOON OF THE RELIAVAC COULD NOT BE INFLATED ON THE DAY OF USE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9341026 ↗MalfunctionNov 5, 2019Inflation Problem; Suction Problem
IT WAS REPORTED THAT THE RELIAVAC WAS UNABLE TO ASPIRATE DURING PRETEST. ANOTHER DEVICE WAS USED. IT WAS LATER REPORTED FROM THE INTERNATIONAL BUSINESS CENTER (IBC) VIA EMAIL 24OCT2019 THAT THE USER ALLEGED THE BALLOON INSIDE DID NOT EXPAND.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9279709 ↗MalfunctionOct 25, 2019Inflation Problem
IT WAS REPORTED THAT IT WAS DIFFICULT TO INFLATE THE BALLOON AFTER PLACEMENT, ON THE DAY OF USE. THE USER DISCONTINUED TO USE THE SUCTION EVACUATOR DUE TO THIS EVENT.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9238931 ↗MalfunctionSep 16, 2019Inflation Problem
IT WAS REPORTED THAT THE EVACUATOR BALLOON WAS DIFFICULT TO INFLATE PRIOR TO USE.
Patient problems: No Known Impact Or Consequence To Patient; No Patient Involvement
MAUDE report 9072530 ↗MalfunctionJul 23, 2019Suction Problem; Suction Problem; Therapeutic or Diagnostic Output Failure
IT WAS REPORTED THAT IT WAS DIFFICULT TO ASPIRATE THE EVACUATOR AS NEGATIVE PRESSURE WAS APPLIED DURING USAGE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 8817717 ↗MalfunctionApr 9, 2019Disconnection
IT WAS REPORTED THAT THE Y CONNECTOR DISCONNECTED FROM THE DRAINAGE TUBE ON THE EVACUATOR BULB.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 8497381 ↗MalfunctionMar 28, 2019Burst Container or Vessel; Material Rupture; Burst Container or Vessel
IT WAS REPORTED THAT THE BALLOON RUPTURED A DAY AFTER USE. IT WAS LATER REPORTED VIA EMAIL ON 18 MARCH 2019 FROM THE INTERNATIONAL BUSINESS CENTER (IBC) REPRESENTATIVE, IT IS UNKNOWN IF THERE WERE MISSING PIECES FROM THE BALLOON.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 8458968 ↗
Other APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED devices
- Closed Wound Suction 0043610C. R. Bard, Inc. · APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED303 reports
- Closed Wound Suction 0070740C. R. Bard, Inc. · APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED192 reports
- Evacuator 0070800C. R. Bard, Inc. · APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED124 reports
- CARDINAL HEALTH SU130-402DCardinal Health 200, LLC · APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED1 recall1 report
- CARDINAL HEALTH SU130-403DCardinal Health 200, LLC · APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED1 recall0 reports
- CARDINAL HEALTH SU130-475Cardinal Health 200, LLC · APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED1 recall0 reports
- DLP® 10061Medtronic, Inc. · APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED1 recall0 reports
- NA 1A8504Baxter International Inc. · APPARATUS, SUCTION, SINGLE PATIENT USE, PORTABLE, NONPOWERED50 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page