Seeker® SK13514Recalls & reported problems
Bard Peripheral Vascular, Inc. · Seeker® Crossing Support Catheter 0.014" Guidewire compatible, 135cm · Class 2
All models of Seeker (9)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00801741067877), received between Jul 11, 2019 and Sep 2, 2026 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Detachment of Device or Device Component3
- Break1
- Device Markings/Labelling Problem1
- Device-Device Incompatibility1
- Failure to Advance1
- Material Deformation1
- Material Split, Cut or Torn1
- Peeled/Delaminated1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- No Consequences Or Impact To Patient1
- No Patient Involvement1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 2, 2026Peeled/Delaminated; Device-Device Incompatibility
On (b)(6) 2026, a patient underwent a recanalization procedure using a Seeker Crossing Support Catheter for the treatment of a calcified superficial femoral artery (SFA) lesion via a contralateral approach. During the procedure, it was reported that the guidewire could not be advanced through the distal tip of the catheter. After multiple attempts, the guidewire was successfully advanced; however, difficulty was subsequently encountered during withdrawal of the guidewire through the distal tip. Upon removal, flaking of the guidewire's polymer coating was observed. There was no reported patient injury.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50559365 ↗MalfunctionApr 8, 2024Retraction Problem; Failure to Advance; Material Deformation; Retraction Problem; Failure to Advance; Material Deformation
IT WAS REPORTED THAT DURING A RECANALIZATION PROCEDURE IN THE SUPERFICIAL FEMORAL ARTERY VIA THE CONTRALATERAL APPROACH, BECAUSE THE BIFURCATION ANGLE WAS TOO TIGHT, THE CATHETER HAD ALLEGEDLY KINKED. IT WAS FURTHER REPORTED THAT THE CATHETER ALLEGEDLY COULD NOT ABLE TO CROSS THE LESION. FURTHERMORE, THE DEVICE ALLEGEDLY HAD RETRACTION PROBLEM. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19057609 ↗MalfunctionJan 23, 2024Detachment of Device or Device Component; Material Split, Cut or Torn; Detachment of Device or Device Component; Material Split, Cut or Torn
IT WAS REPORTED THAT DURING A RECANALIZATION PROCEDURE, THE SUPPORT CATHETER ALLEGEDLY TORN OFF IN A SECTION OF THE CENTIMETER TIP WITHOUT BEING ABLE TO REACH THE INTRODUCER SHEATH. THE PROCEDURE WAS COMPLETED BY USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18565644 ↗MalfunctionDec 15, 2023Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING A RECANALIZATION PROCEDURE, THE TIP OF THE DEVICE WAS ALLEGEDLY WRENCHED OFF. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18333990 ↗MalfunctionJan 6, 2022Device Markings/Labelling Problem; Device Markings/Labelling Problem
IT WAS REPORTED THAT PRIOR TO A RECANALIZATION PROCEDURE, THE PHYSICIAN ALLEGEDLY NOTED THAT THE POSITION OR THE LENGTH OF THE MARKER SEEMED TO BE DIFFERENT. THERE WAS NO PATIENT CONTACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13173902 ↗MalfunctionJul 11, 2019Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component
THIS REPORT SUMMARIZES ONE (1) MALFUNCTION. A REVIEW OF THE REPORTED INFORMATION INDICATED THAT MODEL SK13514 SEEKER CROSSING SUPPORT CATHETER ALLEGEDLY EXPERIENCED A BREAK AND TIP DETACHMENT. THIS INFORMATION WAS RECEIVED FROM * ONE SOURCE. THE MALFUNCTION INVOLVED A PATIENT WITH NO KNOWN IMPACT TO THE PATIENT. PATIENT AGE, WEIGHT, AND GENDER WERE NOT PROVIDED.
Patient problems: No Consequences Or Impact To Patient; No Patient Involvement
MAUDE report 8783027 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page