Clear Advantage Male Continence Sheath 1283Recalls & reported problems
C. R. Bard, Inc. · Clear Advantage with Aloe Clear Silicone Self-Adhesive Male Continence Sheath · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00801741070280), received between May 21, 2021 and Dec 13, 2022 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Nonstandard Device” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Nonstandard Device3
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 13, 2022Nonstandard Device; Nonstandard Device
IT WAS REPORTED THAT THE CUSTOMER ADVISED THE MALE EXTERNAL CATHETERS WERE NOT THE SAME QUALITY AS THEY WERE BEFORE. THE CUSTOMER STATED THAT MOST OF THE MALE EXTERNAL CATHETERS WERE VERY HARD TO ROLL AND SEEMED TO BE LOOKING LIKE THEY WERE STUCK ON THE EDGE, OR THE ADHESIVE HAD DRIED. SOME OF THEM WERE TOUGH AND SOME WERE SOFT. THE CUSTOMER WAS USING TWO SHEATHS A DAY BUT SOMETIMES THEY FORGOT TO CHANGE, AND ONE SHEATH LASTED UP TO 3 DAYS AND SOME OF THEM CAME OFF. THE CUSTOMER STATED THAT THEY HAD DONE EVERYTHING TO ENSURE THE SHEATH STAYS ON, BUT IT JUST UNROLLS. SOMETIMES, IT WAS QUITE HARD TO REMOVE SOME OF THE GLUE THAT WAS LEFT ON THE PENIS ONCE SHEATH WAS REMOVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15968606 ↗MalfunctionAug 30, 2021Nonstandard Device; Nonstandard Device
IT WAS REPORTED THAT THE SHEATHS OF THE MALE EXTERNAL CATHETER WERE LEAVING BEHIND EXCESS GLUE AND WERE DISINTEGRATING WHEN ADHESIVE REMOVER WAS USED. THE PATIENT STATED THAT IT TOOK 10 MINUTES TO CLEANLY REMOVE THE ADHESIVE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12385682 ↗MalfunctionMay 21, 2021Nonstandard Device; Nonstandard Device
IT WAS REPORTED THAT FEW OF THE SHEATHS OF THE MALE EXTERNAL CATHETERS WERE TOO STICKY AND SO COULD NOT BE USED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11867336 ↗
Other DEVICE, INCONTINENCE, UROSHEATH TYPE, NON-STERILE devices
- Spirit® Hydrocolloid Adhesive Sheath 39302C. R. Bard, Inc. · DEVICE, INCONTINENCE, UROSHEATH TYPE, NON-STERILE48 reports
- Spirit® Hydrocolloid Adhesive Sheath 39303C. R. Bard, Inc. · DEVICE, INCONTINENCE, UROSHEATH TYPE, NON-STERILE42 reports
- Spirit® Hydrocolloid Adhesive Sheath 35302C. R. Bard, Inc. · DEVICE, INCONTINENCE, UROSHEATH TYPE, NON-STERILE36 reports
- Spirit® Hydrocolloid Adhesive Sheath 35303C. R. Bard, Inc. · DEVICE, INCONTINENCE, UROSHEATH TYPE, NON-STERILE32 reports
- UltraFlex™ Self-Adhering Male External Catheter 33302C. R. Bard, Inc. · DEVICE, INCONTINENCE, UROSHEATH TYPE, NON-STERILE31 reports
- Spirit® Hydrocolloid Adhesive Sheath 39304C. R. Bard, Inc. · DEVICE, INCONTINENCE, UROSHEATH TYPE, NON-STERILE29 reports
- Wideband™ Self-Adhering Male External Catheter 36302C. R. Bard, Inc. · DEVICE, INCONTINENCE, UROSHEATH TYPE, NON-STERILE29 reports
- Spirit® Hydrocolloid Adhesive Sheath 35304C. R. Bard, Inc. · DEVICE, INCONTINENCE, UROSHEATH TYPE, NON-STERILE25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page