XENMATRIX 1150606Recalls & reported problems
Davol Inc. · XenMatrix AB Surgical Graft, 6 cm x 6 cm · Class 2 · Implant
All models of XENMATRIX (20)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00801741074172), received between Jul 9, 2019 and Jul 9, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Split, Cut or Torn” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Split, Cut or Torn1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 9, 2019Material Split, Cut or Torn; Material Split, Cut or Torn
AS REPORTED, DURING A LAPAROSCOPIC HIATAL HERNIA REPAIR WHILE USING XENMATRIX AB GRAFT, IT "RIPPED" WHEN DEPLOYED DOWN A 12 MM PORT. THE GRAFT WAS REMOVED AND ANOTHER XENMATRIX AB GRAFT WAS THEN USED TO COMPLETE THE CASE WITHOUT FURTHER ISSUE. THERE WAS NO PATIENT INJURY.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8771008 ↗
Other Mesh, surgical, collagen, plastic and reconstructive surgery devices
- RevizeTM-X 611-005-002Tei Biosciences Inc. · Mesh, surgical, collagen, plastic and reconstructive surgery1 recall0 reports
- XENMATRIX 1161935Davol Inc. · Mesh, surgical, collagen, plastic and reconstructive surgery20 reports
- XENMATRIX 1162025Davol Inc. · Mesh, surgical, collagen, plastic and reconstructive surgery7 reports
- Gentrix® MSPL1015Acell, Inc. · Mesh, surgical, collagen, plastic and reconstructive surgery6 reports
- XENMATRIX 1161520Davol Inc. · Mesh, surgical, collagen, plastic and reconstructive surgery5 reports
- Gentrix® PSMX1015Acell, Inc. · Mesh, surgical, collagen, plastic and reconstructive surgery2 reports
- XENMATRIX 1151010Davol Inc. · Mesh, surgical, collagen, plastic and reconstructive surgery1 report
- ACell® PFM0505Acell, Inc. · Mesh, surgical, collagen, plastic and reconstructive surgery1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page