Skip to content

ONFLEX 0115411Recalls & reported problems

Davol Inc. · OnFlex Mesh, 4.0" x 6.2" (10.2 cm x 15.7 cm), Large · Class 2 · Implant

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00801741074431), received between Aug 6, 2018 and Jun 17, 2026 — classified as 3 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 2 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Insufficient Device Problem Information1

Patient problems

  • Hematoma2
  • Hernia1
  • Pain1
  • Seroma1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 17, 2026Adverse Event Without Identified Device or Use Problem

    PER JOURNAL ARTICLE: "FIRST EVALUATION OF THE TREPP PROCEDURE FOR INGUINOSCROTAL HERNIA REPAIR: A STEP-UP STUDY" THE AIM OF THIS STUDY IS TO EVALUATE THE CLINICAL OUTCOME OF THE TREPP PROCEDURE SPECIFICALLY IN THE TREATMENT OF SCROTAL HERNIAS. TRANSRECTUS SHEATH PRE-PERITONEAL (TREPP) MESH REPAIR. THIS RETROSPECTIVE STUDY ANALYZED CONSECUTIVE PATIENTS WHO UNDERWENT TREPP REPAIR FOR SCROTAL HERNIA BETWEEN JANUARY 2021 AND DECEMBER 2023. EITHER A MEDIUM (8.6CMX14.2CM) OR A LARGE (10.2CMX15.7CM) ONFLEX¿ MESH WAS USED, DEPENDING ON THE SIZE OF THE PREPERITONEAL SPACE. A TOTAL OF 33 PRIMARY SCROTAL HERNIA CASES WERE ANALYZED AND TREATED WITH THE TREPP PROCEDURE. OF THESE, 33 PROCEDURES WERE PERFORMED FOR A PRIMARY SCROTAL HERNIA, ONE PATIENT WAS TREATED BECAUSE OF RECURRENT SCROTAL HERNIA AND WAS EXCLUDED FROM FURTHER ANALYSIS NO RECURRENCE WAS REPORTED WITHIN THIS TIMEFRAME. COMPLICATIONS WERE MINIMAL, WITH ONLY ONE PATIENT (3.0%) DEVELOPING NEUROPATHIC PAIN DUE TO ACNES, WHICH WAS RESOLVED COMPLETELY AFTER APPROPRIATE LOCAL INJECTIONS (NOT RELATED TO THE IMPLANT). TWO PATIENTS (6.1%) EXPERIENCED SUPERFICIAL INFECTIONS THAT WERE SUCCESSFULLY MANAGED WITH ANTIBIOTICS, AND NO MESH INFECT

    Patient problems: Hematoma; Seroma

    MAUDE report 25537330 ↗
  • InjuryJun 17, 2026Adverse Event Without Identified Device or Use Problem

    PER JOURNAL ARTICLE: "COMPARISON OF THE ONSTEP AND LICHTENSTEIN TECHNIQUES FOR INGUINAL HERNIA REPAIR-EARLY RESULTS OF A PROSPECTIVE STUDY" THE ARTICLE PRESENTS A STUDY OF 41 MEN RANDOMIZED INTO 2 STUDY GROUPS, UNILATERAL INGUINAL HERNIA REPAIR WAS PERFORMED USING THE ONSTEP TECHNIQUE IN GROUP O AND THE LICHTENSTEIN TECHNIQUE IN GROUP L. A TOTAL OF 34 MEN MET THE FULL INCLUSION CRITERIA, WITH EACH GROUP CONSISTING OF 17 PATIENTS. DATA WERE COLLECTED PROSPECTIVELY DURING HOSPITALIZATION, AS WELL AS ON DAY 7 AND AT 3 AND 12 MONTHS POSTOPERATIVELY. PAIN INTENSITY WAS ASSESSED USING THE NUMERICAL RATING SCALE (NRS). THE SEVERITY OF THE SYSTEMIC INFLAMMATORY RESPONSE SYNDROME (SIRS) WAS EVALUATED BASED ON CHANGES IN THE FOLLOWING PARAMETERS: LEUKOCYTE AND PLATELET COUNTS, LEVELS OF INTERLEUKIN-6, C-REACTIVE PROTEIN (CRP), AND FIBRINOGEN AT 6, 24, 46, AND 168 HOURS POSTOPERATIVELY. POSTOPERATIVE COMPLICATIONS OF THE TECHNIQUES INCLUDED 6 CASE OF LOCAL HEMATOMA ON GROIN (GROUP O N=2, GROUP L N=4), 3 CASE OF LOCAL HEMATOMA ON SCROTAL (GROUP O N=2, GROUP L N=1), 7 CASES WITH SUBCUTANEOUS HEMATOMA (GROUP O N=4 AND GROUP L N=3), 1 CASE OF URINARY RETENTION (GROUP O N=1) (URINARY RETENTION IS

    Patient problems: Hematoma; Pain

    MAUDE report 25530737 ↗
  • InjuryAug 6, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT ON (B)(6) 2018 THE PATIENT UNDERWENT THE REPAIR OF A LEFT INGUINAL HERNIA. THE SURGEON REPORTS THE PROCEDURE WAS ¿PERFECTLY ADEQUATE¿ AND ¿FELT THE MESH WAS PLACED WELL.¿ TEN DAYS POSTOPERATIVE A RECURRENCE WAS IDENTIFIED. TO DATE THERE HAS BEEN NO SURGICAL INTERVENTION.

    Patient problems: Hernia

    MAUDE report 7754417 ↗