Skip to content

STATLOCK VPPDFPCERecalls & reported problems

Bard Access Systems, Inc. · SL PICC PLUS CRESC FOAM FIXED POST CE · Class 1

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00801741083396), received between Jun 19, 2024 and Sep 23, 2026 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Difficult to Remove” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Remove3
  • Loss of or Failure to Bond1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 23, 2026Difficult to Remove

    It was reported it¿s not possible to adjust the blue tabs in the middle. This means the StatLocks don¿t fit. The plaster sticks firmly to the skin, making it almost impossible to remove the dressing. No further information was provided. An exact number of occurrences or devices was not provided by the complainant.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50870552 ↗
  • MalfunctionMar 24, 2026Difficult to Remove

    IT WAS REPORTED DIFFICULTIES ARE ENCOUNTERED DURING REMOVAL. NO FURTHER INFORMATION WAS PROVIDED. AN EXACT NUMBER OF OCCURRENCES WAS NOT PROVIDED BY THE COMPLAINANT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24676903 ↗
  • MalfunctionJun 19, 2024Loss of or Failure to Bond; Difficult to Remove; Loss of or Failure to Bond; Difficult to Remove

    IT WAS REPORTED BY THE CUSTOMER THAT "STATLOCKS ADHERING TO THE 3M BORDERED DRESSINGS, I ASKED THE STAFF ON 5A TO REPORT ANY INSTANCES TO ME SO I COULD INVESTIGATE WHERE THE PREVIOUS DRESSING HAD BEEN DONE EXTERNALLY." CUSTOMER MAY NOT BE USING COMPATIBLE COMPETITOR DRESSING WITH OUR STATLOCK DRESSING TOOK ADDITIONAL 20 MINUTES TO REMOVE DRESSING AND STAT LOCK. THE FOAM BECAME IMPOSSIBLE TO REMOVE. THE ONLY WAY THE RN COULD DO WAS USE ALCOHOL WAND. THE DRESSING ALSO SEEMS TO BE MORE DIFFICULT TO REMOVE FROM THE STAT LOCK. NO OTHER INFORMATION WAS PROVIDED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19566840 ↗

Other DEVICE, INTRAVASCULAR CATHETER SECUREMENT devices

All DEVICE, INTRAVASCULAR CATHETER SECUREMENT devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.