LIFESTENT® 5F071003CSRecalls & reported problems

Bard Peripheral Vascular, Inc. · LIFESTENT® 5F Vascular Stent System, 7 mm x 100 mm (135 cm delivery catheter) · Class 3 · Implant

All models of LIFESTENT (28)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
5
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00801741120343), received between Jun 1, 2022 and Jul 27, 2026 — classified as 5 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Break” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 1 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break7
  • Detachment of Device or Device Component7
  • Activation Failure1
  • Difficult to Advance1
  • Material Deformation1
  • Migration or Expulsion of Device1
  • Packaging Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available3
  • Foreign Body In Patient3

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 27, 2026Break; Detachment of Device or Device Component; Difficult to Advance

    On (b)(6)2026, a patient underwent stent placement procedure using a Lifestent device via common femoral artery in the right groin. It was reported that the tip of the delivery catheter broke on the stent and the two hollow outer sheaths broke. It was further reported that the physician tried snaring one of the two pieces which further migrated both distally. One segment parked in a collateral. The other piece was parked with a coronary stent in the profunda which remained patent. However, the current condition of the patient is unknown.

    Patient problems: Foreign Body In Patient; No Clinical Signs, Symptoms or Conditions

    MAUDE report 50020952 ↗
  • MalfunctionSep 30, 2025Material Deformation; Activation Failure; Material Deformation; Activation Failure

    A PATIENT UNDERWENT A STENT PLACEMENT PROCEDURE USING LIFESTENT 5F VASCULAR STENT. DURING THE PROCEDURE, IT WAS REPORTED THAT LIFESTENT ALLEGEDLY DID NOT EXPAND TO ITS FULL INTENDED LENGTH THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23177733 ↗
  • MalfunctionAug 6, 2025Packaging Problem; Packaging Problem

    A PATIENT WAS PREPPED FOR A STENT PLACEMENT PROCEDURE USING THE LIFESTENT 5F VASCULAR STENT. IT WAS REPORTED THAT PRIOR TO STENT PLACEMENT PROCEDURE, THE DEVICES ALLEGEDLY DAMAGED INSIDE THE PACKAGE. THERE WAS NO PATIENT CONTACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22726491 ↗
  • InjuryApr 9, 2025Break; Migration or Expulsion of Device; Detachment of Device or Device Component; Break; Migration or Expulsion of Device; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE, THE STENT ALLEGEDLY BROKE OFF. IT WAS FURTHER REPORTED THAT THE BROKEN FRAGMENT ALLEGEDLY MIGRATED TO THE ARTERY. FURTHERMORE, AN OPEN CUTDOWN WAS CARRIED OUT AND THE FRAGMENT RETRIEVED. THE CURRENT STATUS OF THE PATIENT IS STABLE NOW.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 21804407 ↗
  • InjuryJan 16, 2025Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE IN THE RIGHT LOWER EXTREMITY ANGIOGRAM, THE PIECE OF THE STENT DEPLOYMENT SYSTEM BROKE OFF AND REMAINED IN THE ARTERY. IT WAS FURTHER REPORTED THAT AN OPEN CUTDOWN WAS CARRIED OUT AND THE FRAGMENT RETRIEVED. THE CURRENT STATUS OF THE PATIENT IS STABLE.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 21165634 ↗
  • InjuryDec 29, 2024Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE IN LEFT COMMON FEMORAL ARTERY, THE TIP OF THE STENT DEVELOPMENT SYSTEM ALLEGEDLY BROKE OFF AND BECAME LODGED INSIDE THE BLOOD VESSEL. IT WAS ALSO REPORTED THAT SNARES WERE USED TO TRY AND RETRIEVE THE CATHETER FRAGMENTS BUT WERE UNSUCCESSFUL. AN OPEN PROCEDURE INVOLVES CUTTING THE ARTERY TO VISUALIZE AND REMOVE CATHETER PIECES. THE PATIENT¿S CURRENT STATUS IS UNKNOWN.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 21032777 ↗
  • InjuryNov 23, 2024Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE, THE TIP OF THE DELIVERY SYSTEM ALLEGEDLY DETACHED. IT WAS FURTHER REPORTED THAT THE BROKEN PART OF THE DEVICE CANNOT BE SNARED OUT' THEREFORE, THE PATIENT HAD TO HAVE ADDITIONAL MEDICAL INTERVENTION WITH A BYPASS TO REMOVE THE TIP OF THE CATHETER. THE CURRENT STATUS OF PATIENT IS UNKNOWN.

    Patient problems: Foreign Body In Patient

    MAUDE report 20766341 ↗
  • InjuryMay 23, 2024Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE IN THE CALCIFIED DISTAL SUPERFICIAL FEMORAL ARTERY VIA THE COMMON FEMORAL ACCESS, THE STENT DEPLOYMENT SYSTEM ALLEGEDLY BROKE INTO TWO PIECE INSIDE THE PATIENT. IT WAS FURTHER REPORTED THAT ONE BROKEN PIECE WAS REMOVED USING A SNARE AND A STENT WAS PLACED TO TRAP THE OTHER PIECE. THE CURRENT STATUS OF THE PATIENT IS UNKNOWN.

    Patient problems: Foreign Body In Patient

    MAUDE report 19379557 ↗
  • MalfunctionJun 1, 2022Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE THROUGH COMMON FEMORAL ARTERY OVER CROSS OVER APPROACH OF A CALCIFIED AND TORTUOUS VESSEL, THE NOSE CONE AND DISTAL PORTION OF THE STENT DELIVERY SYSTEM ALLEGEDLY BROKE OFF IN THE PATIENT. IT WAS FURTHER REPORTED THAT ANOTHER STENT WAS PLACED IN SUPERFICIAL FEMORAL ARTERY TO TRAP THE BROKEN PIECE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions