Bard Peripheral Vascular, Inc. · LIFESTENT® 5F Vascular Stent System, 5 mm x 100 mm (135 cm delivery catheter) · Class 3 · Implant

All models of LIFESTENT (28)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00801741120640), received between Dec 19, 2018 and Aug 22, 2024 — classified as 1 injury, 9 malfunctions.

The most frequently reported specific device problem is “Break” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break7
  • Detachment of Device or Device Component5
  • Difficult to Remove3
  • Material Deformation2
  • Device-Device Incompatibility1
  • Malposition of Device1
  • Material Invagination1
  • Misfire1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7
  • No Consequences Or Impact To Patient2
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 22, 2024Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE IN THE SUPERFICIAL FEMORAL ARTERY VIA LEFT FEMORAL ACCESS, THE COMPONENTS OF THE DEVICE WERE ALLEGEDLY FOUND NOT TO BE INTACT AT THE BASE TOWARDS HANDLE DURING ADVANCEMENT TO THE SHEATH. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20030574 ↗
  • MalfunctionOct 17, 2023Break; Detachment of Device or Device Component; Break; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE, THE CATHETER WAS ALLEGEDLY BROKE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17948220 ↗
  • InjuryJun 19, 2023Break; Malposition of Device; Detachment of Device or Device Component; Break; Malposition of Device; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE IN THE SUPERFICIAL FEMORAL ARTERY, A PIECE OF THE DEPLOYMENT DEVICE WAS ALLEGEDLY BREAK OFF AND GOT STUCK IN THE PATIENT. IT WAS FURTHER REPORTED THAT SNARE AND BALLOON WAS USED TO RETRIEVE THE PIECE. REPORTEDLY, PATIENT ENDED UP WITH KNEE AMPUTATION. THE CURRENT STATUS OF THE PATIENT IS UNKNOWN.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 17150480 ↗
  • MalfunctionJan 30, 2023Break; Difficult to Remove; Detachment of Device or Device Component; Break; Difficult to Remove; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE THROUGH FEMORAL ARTERY, THE STENT ALLEGEDLY DETACHED INTO PIECES. IT WAS FURTHER REPORTED THAT THERE WAS A LIGHT TENSION WHEN INITIALLY RETRACTING THE STENT FROM DEPLOYMENT LOCATION. REPORTEDLY, THE DETACHED SEGMENTS WERE REMOVED USING SNARE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16264018 ↗
  • MalfunctionJul 27, 2022Material Deformation; Positioning Problem; Material Deformation; Positioning Problem

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE, THE STENT ALLEGEDLY HAD A POSITIONING PROBLEM. IT WAS FURTHER REPORTED THAT CATHETER ALLEGEDLY BUCKLED. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15110827 ↗
  • MalfunctionFeb 16, 2022Material Invagination; Premature Activation; Material Invagination; Premature Activation

    IT WAS REPORTED THAT DURING A STENT PLACEMENT SUPERFICIAL ARTERY (SFA) PROCEDURE THROUGH THE COMMON FEMORAL ACCESS, THE CATHETER TIP ALLEGEDLY PREMATURELY DEPLOYED AS IT WAS BEING ADVANCED ACROSS THE LESION. THE PROCEDURE WAS COMPLETED BY USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13539797 ↗
  • MalfunctionDec 7, 2020Break; Break

    IT WAS REPORTED THAT DURING THE STENT PLACEMENT, THE DEVICE ALLEGEDLY BROKE. IT WAS FURTHER REPORTED THAT IT WAS NOT BROKE INSIDE THE PATIENT, HOWEVER IT WAS NOTED AFTER PULLING OUT FROM THE PATIENT. THE PROCEDURE WAS COMPLETED USING A SNARE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10956836 ↗
  • MalfunctionDec 4, 2020Break; Break

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE, THE INNER CATHETER WAS BROKE INSIDE THE PATIENT AFTER DEPLOYING THE STENT. IT WAS FURTHER REPORTED THAT THE BROKEN PARTICLES REMOVED WITH THE HELP OF SNARE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10947671 ↗
  • MalfunctionJul 10, 2020Break; Difficult to Remove; Detachment of Device or Device Component; Break; Difficult to Remove; Detachment of Device or Device Component

    THIS REPORT SUMMARIZES ONE MALFUNCTION. A REVIEW OF THE REPORTED INFORMATION INDICATES THAT MODEL 5F051003CS VASCULAR STENT ALLEGEDLY EXPERIENCED DETACHMENT. THIS INFORMATION WAS RECEIVED FROM ONE SOURCE. ONE PATIENT WAS INVOLVED WITH NO REPORTED PATIENT INJURY. THE FEMALE PATIENT IS (B)(6) AND WEIGHS (B)(6).

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10261400 ↗
  • MalfunctionDec 19, 2018Difficult to Remove; Misfire; Device-Device Incompatibility; Material Deformation; Difficult to Remove; Misfire; Device-Device Incompatibility; Material Deformation

    IT WAS REPORTED THAT DURING A STENT PLACEMENT PROCEDURE INTENDED FOR A CALCIFIED RIGHT FEMORAL ARTERY VIA ACCESS THROUGH THE LEFT FEMORAL ARTERY, THE STENT ALLEGEDLY PARTIALLY DEPLOYED APPROXIMATELY TWO CENTIMETERS USING THE THUMBWHEEL DEPLOYMENT WHEEL. IT WAS FURTHER REPORTED THAT THERE WAS ALLEGED DIFFICULTY REMOVING THE DELIVERY SYSTEM AND THE GUIDEWIRE BECAME STUCK IN THE SYSTEM. ANGIOPLASTY WAS PERFORMED TO COMPLETE THE PROCEDURE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8182102 ↗

Other STENT, SUPERFICIAL FEMORAL ARTERY devices

All STENT, SUPERFICIAL FEMORAL ARTERY devices →