LUTONIX ® 035 Drug Coated Balloon PTA Catheter LX3575640VRecalls & reported problems

Lutonix, Inc. · Lutonix® AV Drug Coated Balloon PTA Catheter 6x40x75 · Class 3

All models of LUTONIX 035 Drug Coated Balloon PTA Catheter (19)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00801741135385), received between Oct 31, 2018 and Oct 3, 2023 — classified as 2 injuries, 1 malfunction.

The most frequently reported specific device problem is “Material Rupture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Material Rupture1

Patient problems

  • No Consequences Or Impact To Patient1
  • Reocclusion1
  • Restenosis1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 3, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THROUGH THE RESULTS OF A CLINICAL TRIAL THAT THREE MONTHS AND THIRTY DAYS POST INDEX PROCEDURE USING A DRUG-COATED BALLOON CATHETER IN THE CEPHALIC VEIN, THE SUBJECT DEVELOPED A SERIOUS ADVERSE EVENT OF STENOSIS OF THE CEPHALIC VEIN WHICH REQUIRED AN ADDITIONAL ARTERIOVENOUS ACCESS CIRCUIT REINTERVENTION. IT WAS FURTHER REPORTED THAT THE NEW LESION WITHIN THE ACCESS CIRCUIT IN THE LEFT FOREARM WAS SUCCESSFULLY TREATED WITH DRUG COATED BALLOON CATHETER. IT WAS ALSO REPORTED THAT SIX MONTHS AND THREE DAYS POST INDEX PROCEDURE, THE SUBJECT DEVELOPED A SERIOUS ADVERSE EVENT OF STENOSIS OF THE CEPHALIC VEIN WHICH REQUIRED AN ADDITIONAL ARTERIOVENOUS ACCESS CIRCUIT REINTERVENTION. FURTHERMORE, THE NEW LESION WITHIN THE ACCESS CIRCUIT IN THE LEFT FOREARM WAS SUCCESSFULLY TREATED WITH STANDARD PERCUTANEOUS TRANSLUMINOUS ANGIOPLASTY BALLOON CATHETER. THE RE-INTERVENTION WAS SUCCESSFUL, NO NEW ACCESS CREATED, AND THE OUTCOME WAS RECOVERED. REPORTEDLY, THERE HAVE BEEN NO DOCUMENTED DEVICE DEFICIENCIES REPORTED FOR THIS SUBJECT TO DATE. THE CURRENT STATUS OF THE PATIENT IS UNKNOWN.

    Patient problems: Restenosis

    MAUDE report 17859489 ↗
  • InjuryAug 28, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THROUGH A POST MARKET APPROVAL STUDY DURING THE INDEX PROCEDURE, A LUTONIX PERCUTANEOUS TRANSLUMINAL DRUG COATED BALLOON (DCB) DILATATION CATHETER WAS USED TO TREAT THE TARGET LESION IN THE LEFT FOREARM CEPHALIC VEIN. APPROXIMATELY 150 DAYS POST INDEX PROCEDURE, THE TARGET LESION WAS REOCCLUDED. RE-INTERVENTION WAS PERFORMED WITH SUCCESSFUL RESULT. THE INVESTIGATOR ASSESSED THE REOCCLUSION EVENT WAS NOT RELATED TO THE STUDY DEVICE AND POSSIBLY RELATED TO THE INDEX PROCEDURE.

    Patient problems: Reocclusion

    MAUDE report 8942417 ↗
  • MalfunctionOct 31, 2018Material Rupture; Material Rupture

    IT WAS REPORTED A LUTONIX PERCUTANEOUS TRANSLUMINAL DRUG COATED BALLOON (DCB) DILATATION CATHETER ALLEGEDLY RUPTURED AT NOMINAL PRESSURE WHILE TREATING THE TARGET LESION IN THE AV FISTULA. THE HEALTH CARE PROFESSIONAL (HCP) DISCARDED THE LUTONIX DCB AND IT IS NOT AVAILABLE FOR EVALUATION. ALTHOUGH REQUESTED MULTIPLE TIMES, ADDITIONAL EVENT DETAILS AND PATIENT DEMOGRAPHICS ARE UNAVAILABLE. NO ADVERSE PATIENT OUTCOMES WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8023835 ↗

Other Drug-coated peripheral transluminal angioplasty catheter devices