Skip to content

PureWick PWF030FXRecalls & reported problems

C. R. Bard, Inc. · PureWick Flex Female External Catheter, Acute Care · Class 1

All models of PureWick (6)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00801741226960), received between Sep 17, 2026 and Sep 17, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Patient Device Interaction Problem1

Patient problems

  • Bacterial Infection1
  • Fever1
  • Urinary Tract Infection1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjurySep 17, 2026Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem

    It was reported that suspected urinary tract infection. 86-year-old female August 18: Started using PureWick FLEX (nighttime only). (b)(6): Discontinued use due to absence of nighttime urination. (b)(6): Resumed use following an episode of nighttime urinary incontinence. (b)(6): Experienced an episode of nighttime fecal incontinence; the device was removed due to fecal contamination on the gauze section of the PureWick. (b)(6): During a home visit, it was reported that the patient had a fever and a urinalysis showed 3+ bacteria; use of the PureWick remains suspended. The device was last used on the night of (b)(6). The patient's condition is stable. It was noted that daytime calls for toileting assistance had decreased over the past week, and fluid intake appeared to be low. The decision was made to keep use suspended as a precaution.

    Patient problems: Bacterial Infection; Fever; Urinary Tract Infection

    MAUDE report 50809425 ↗

FDA clearance and classification

The FDA regulates product code NZU (collector, urine, powered, non indwelling catheter) under 21 CFR 876.5250 as a Class I device. 21 CFR 876.5250 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the PureWick PWF030FX

Has the PureWick PWF030FX been recalled?

No FDA recall record in our data names this exact device identifier (DI 00801741226960), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the PureWick PWF030FX?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Sep 17, 2026. That report lists device problem “Patient Device Interaction Problem” (1); patient problems “Bacterial Infection” (1), “Fever” (1) and “Urinary Tract Infection” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the PureWick PWF030FX?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the PureWick PWF030FX FDA approved?

Devices of this type (product code NZU) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by C. R. Bard, Inc.

Is the PureWick PWF030FX MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the PureWick PWF030FX, and is it still sold?

The FDA's device database lists C. R. Bard, Inc. as the company responsible for it (brand PureWick, model PWF030FX). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Collector, urine, powered, non indwelling catheter devices

All Collector, urine, powered, non indwelling catheter devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page