ARROW IPN030072Recalls & reported problems

Teleflex Incorporated · Two-Lumen Hemodialysis Catheterization Set with Blue FlexTip(R) Catheter for High Volume Infusions · Class 2

All models of ARROW (1494)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00801902100122), received between Jul 12, 2023 and May 2, 2025 — classified as 8 malfunctions.

The most frequently reported specific device problem is “Unraveled Material” (4 reports).

1 other recall cover devices cleared under the same FDA submission (K991431); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 3 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Unraveled Material4
  • Fitting Problem3
  • Physical Resistance/Sticking3
  • Difficult to Remove2
  • Break1
  • Difficult to Advance1
  • Material Separation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • Hematoma1
  • Needle Stick/Puncture1
  • Pain1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 2, 2025Difficult to Remove; Difficult to Remove

    IT WAS REPORTED THAT " DURING DIALYSIS CATHETER INSERTION IT WAS IMPOSSIBLE TO REMOVE THE GUIDE. THE CONSEQUENCES WERE PAIN FOR THE PATIENT." A NEW PUNCTURE KIT WAS USED TO COMPLETE THE PROCEDURE. THERE WAS NO MEDICAL INTERVENTION REQUIRED. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "FINE."

    Patient problems: Pain

    MAUDE report 21950155 ↗
  • MalfunctionApr 23, 2025Difficult to Remove; Difficult to Advance; Physical Resistance/Sticking; Difficult to Remove; Difficult to Advance; Physical Resistance/Sticking

    IT WAS REPORTED "DURING INSERTION THE GUIDE WAS IMPOSSIBLE TO ADVANCE, AND IT GOT STUCK, IT WAS IMPOSSIBLE TO REMOVE. THE DEVICE WAS REPLACED." ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER STATES "RESISTANCE WAS OBSERVED WHEN I TRIED TO LOWER THE GUIDE INTO THE NEEDLE, PROMPTING ME TO MOVE THE NEEDLE. I THOUGHT IT WAS BLOCKED AGAINST THE WALL, SO I REPOSITIONED MY NEEDLE, WITHOUT SUCCESS. SO I WANTED TO REMOVE THE GUIDE TO SEE IF THERE WAS STILL BLOOD REFLUX AND CHECK THAT THE NEEDLE WAS STILL IN THE VEIN, BUT I COULDN'T REMOVE THE GUIDE AND HAD TO REMOVE THE GUIDE AND NEEDLE." THE DEVICE WAS REMOVED, AND A NEW SET WAS USED REQUIRING THE PATIENT TO BE RE-PUNCTURED THREE TIMES WHICH RESULTED IN A HEMATOMA. THE THIRD INSERTION WAS A SUCCESS. THERE WAS NO MEDICAL INTERVENTION REQUIRED. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "DECEASED". THE CUSTOMER REPORTS "PATIENT DECEASED WITHIN THE FIRST 48 HOURS OF TREATMENT (DEATH HAS NO LINK WITH THE INCIDENT)."

    Patient problems: Hematoma; Needle Stick/Puncture

    MAUDE report 21889725 ↗
  • MalfunctionJan 2, 2025Physical Resistance/Sticking; Physical Resistance/Sticking

    IT WAS REPORTED THAT "SWG DEFECTIVE STUCK IN NEEDLE". ADDITIONAL INFORMATION REPORTED THAT THE GUIDEWIRE WAS "SKEWERED" BY THE PUNCTURE NEEDLE, MAKING IT IMPOSSIBLE TO DISASSEMBLE. AS A RESULT, ANOTHER GUIDEWIRE HAD TO RESOLVE THE ISSUE. THE PATIENT IS FINE AND HAD NO HARM OR INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21055040 ↗
  • MalfunctionJun 10, 2024Unraveled Material; Fitting Problem; Unraveled Material; Fitting Problem

    IT WAS REPORTED "THE WIRE IS TOO THICK FOR THE ARS AND IT SOMETIMES MEETS WITH RESISTANCE BEFORE THE WIRE EVEN EXITS THE TIP OF NEEDLE". ADDITIONAL INFORMATION REPORTS, THE GUIDEWIRE GOT STUCK IN THE SYRINGE ONCE THE WIRE UNRAVELLED. THE DEVICE WAS REMOVED. THERE WAS NO PATIENT HARM OR INJURY. NO MEDICAL INTERVENTION REQUIRED. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "FINE".

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19497788 ↗
  • MalfunctionJun 10, 2024Unraveled Material; Fitting Problem; Unraveled Material; Fitting Problem

    IT WAS REPORTED "THE WIRE IS TOO THICK FOR THE ARS AND IT SOMETIMES MEETS WITH RESISTANCE BEFORE THE WIRE EVEN EXITS THE TIP OF NEEDLE". ADDITIONAL INFORMATION REPORTS, THE GUIDEWIRE GOT STUCK IN THE SYRINGE ONCE THE WIRE UNRAVELLED. THE DEVICE WAS REMOVED. THERE WAS NO PATIENT HARM OR INJURY. NO MEDICAL INTERVENTION REQUIRED. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "FINE".

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19497755 ↗
  • MalfunctionJun 10, 2024Unraveled Material; Fitting Problem; Unraveled Material; Fitting Problem

    IT WAS REPORTED "THE WIRE IS TOO THICK FOR THE ARS AND IT SOMETIMES MEETS WITH RESISTANCE BEFORE THE WIRE EVEN EXITS THE TIP OF NEEDLE". ADDITIONAL INFORMATION REPORTS, THE GUIDEWIRE GOT IN THE STUCK SYRINGE ONCE THE WIRE UNRAVELLED. THE DEVICE WAS REMOVED. THERE WAS NO PATIENT HARM OR INJURY. NO MEDICAL INTERVENTION REQUIRED. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "FINE".

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19497683 ↗
  • MalfunctionMay 29, 2024Break; Material Separation; Break; Material Separation

    IT WAS REPORTED "GUIDEWIRE BROKE OFF IN THE RAULERSON SYRINGE". THE DEVICE WAS REMOVED. NO PATIENT HARM OR INJURY. NO MEDICAL INTERVENTION REQUIRED. THE PATIENT'S CURRENT CONDITION IS REPORTED AS "UNKNOWN".

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19418343 ↗
  • MalfunctionJul 12, 2023Unraveled Material; Physical Resistance/Sticking; Unraveled Material; Physical Resistance/Sticking

    DURING THE INSERTION OF THE CATHETER, "THE NEEDLE UNRAVELED THE SWG DURING REMOVAL". THE PHYSICIAN SLOWLY REMOVED THE CATHETER AND GUIDEWIRE TOGETHER AND ANOTHER DEVICE WAS USED. NO PATIENT HARM WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17304819 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K991431. One submission often covers many models, so check the product and lot details in each record.

  • Z-0639-04 · Feb 18, 2004 · Terminated
    Two Lumen 14F Hemodialysis Catheter Kits/Sets with Blue FlexTip Arrowg+ard Blue Curved Catheter for high Volume Ifusions

Other CATHETER, HEMODIALYSIS, NON-IMPLANTED devices

All CATHETER, HEMODIALYSIS, NON-IMPLANTED devices →