CORE Shoulder System 87-9136Recalls & reported problems
Link Bio Corp · Workstation · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810022403099), received between Mar 6, 2026 and Mar 6, 2026 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device Displays Incorrect Message” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Recalls naming this device
- Mar 12, 2026Class IIOpen, Classified
The CORE Workstation may display an incorrect "Planning Date " when viewing cases on the "Start Case" menu screen.
Z-1810-2026 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported problems
Device problems
- Device Displays Incorrect Message1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 6, 2026Device Displays Incorrect Message
TWO CORE WORKSTATIONS IN INVENTORY WERE FOUND TO HAVE OUT-OF-SYNC TIME/DATE. AN ENGINEER LOGGED INTO THE SERVICE ACCOUNT FOR EACH WORKSTATION TO VIEW THE TIME AND DATE DISPLAYED ON THE TABLET'S CLOCK AND THEY WERE OBSERVED TO BE OUT-OF-SYNC BY SEVERAL MONTHS. AN ENGINEER THEN RE-SYNCED THESE WORKSTATIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24539180 ↗
FDA clearance and classification
Cleared through 510(k) K241470 on Feb 20, 2025 (decision: Substantially Equivalent). Submitted by LinkBio Corp. as “CORE Shoulder System”. The FDA review took 272 days. FDA record ↗
The FDA regulates product code QHE (shoulder arthroplasty implantation system) under 21 CFR 888.3660 as a Class II device. 21 CFR 888.3660 ↗
FDA definition of this device type: Intended to be used to assist in the implantation of a specific shoulder arthroplasty device or a set of specific shoulder arthroplasty devices. Indicated to include guiding alignment, making or establishing cuts, selecting, sizing, attaching, positioning or orienting implant components.
Common questions about the CORE Shoulder System 87-9136
Has the CORE Shoulder System 87-9136 been recalled?
Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-1810-2026 (Class II), began on Mar 12, 2026: The CORE Workstation may display an incorrect "Planning Date " when viewing cases on the "Start Case" menu screen. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
What problems have been reported with the CORE Shoulder System 87-9136?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 6, 2026. That report lists device problem “Device Displays Incorrect Message” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CORE Shoulder System 87-9136?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CORE Shoulder System 87-9136 FDA approved?
It was cleared through 510(k) K241470 on Feb 20, 2025. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the CORE Shoulder System 87-9136, and is it still sold?
The FDA's device database lists Link Bio Corp as the company responsible for it (brand CORE Shoulder System, model 87-9136). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Shoulder Arthroplasty Implantation System devices
- Blueprint BPUE001Tornier · Shoulder arthroplasty implantation system1 recall0 reports
- Blueprint BPUE001Tornier · Shoulder arthroplasty implantation system1 recall0 reports
- Comprehensive® Reverse Shoulder Augmented Guide and Bone Model Right 20-8090-004-02Orthosoft Inc · Shoulder Arthroplasty Implantation System1 report
- Comprehensive® Reverse Shoulder Augmented Guide and Bone Model Left 20-8090-004-01Orthosoft Inc · Shoulder Arthroplasty Implantation System1 report
- Arthrex® 5566VIPArthrex, Inc. · Shoulder arthroplasty implantation system1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page