Skip to content

EF1 DNE-6000-036Recalls & reported problems

Medshape, Inc. · Nut - 10mm · Class 2

All models of EF1 (4)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810028397217), received between Mar 11, 2025 and Mar 11, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Detachment of Device or Device Component1

Patient problems

  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 11, 2025Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem; Detachment of Device or Device Component; Adverse Event Without Identified Device or Use Problem

    REVISION SURGERY - DUE TO POST-OP X-RAY SHOWED A BROKEN 5MM HALF PIN IN THE TIBIA. DOCTOR EXPLAINED THAT THE MOST PROXIMAL HALF PIN HAD BECOME DETACHED FROM THE FRAME AND THE PATIENT HAD SUBSEQUENTLY BROKEN THE MOST DISTAL TIBIAL HALF PIN. ALSO, SOME OF THE NUTS WERE ROUNDED AND CROSS THREADED. HE COMMENTED THAT THE METAL WAS TOO SOFT.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Insufficient Information

    MAUDE report 21579854 ↗

FDA clearance and classification

Cleared through 510(k) K113106 on Jan 4, 2012 (decision: Substantially Equivalent). Submitted by Dne, LLC as “Dne External Fixation System”. The FDA review took 76 days. FDA record ↗

The FDA regulates product code KTT (appliance, fixation, nail/blade/plate combination, multiple component) under 21 CFR 888.3030 as a Class II device. 21 CFR 888.3030 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the EF1 DNE-6000-036

Has the EF1 DNE-6000-036 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00810028397217), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the EF1 DNE-6000-036?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Mar 11, 2025. That report lists device problem “Detachment of Device or Device Component” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the EF1 DNE-6000-036?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the EF1 DNE-6000-036 FDA approved?

It was cleared through 510(k) K113106 on Jan 4, 2012. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the EF1 DNE-6000-036 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Unsafe: it should not be taken into an MRI scanner room.

Who makes the EF1 DNE-6000-036, and is it still sold?

The FDA's device database lists Medshape, Inc. as the company responsible for it (brand EF1, model DNE-6000-036). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component devices

All Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page